hit counter script
Bosch D9133TTL-E Installation Manual

Bosch D9133TTL-E Installation Manual

Network interface module
Table of Contents

Advertisement

Quick Links

D9133TTL-E
Installation Guide
Network Interface
EN
Module

Advertisement

Table of Contents
loading

Summary of Contents for Bosch D9133TTL-E

  • Page 1 D9133TTL-E Installation Guide Network Interface Module...
  • Page 2 D9133TTL-E | Installation Guide | Trademarks Trademarks ® ® ® Microsoft Windows , Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Bosch Security Systems, Inc. | 6/07 | 4998122717-01...
  • Page 3: Table Of Contents

    Tables Additional UL Requirements ......16 Table 1: D9133TTL-E Connection Sequence ....8 UL Listings and Approvals ......18 Table 2: D9133TTL-E Ethernet Status LED Function. 9 Specifications ..........18 Table 3: Netmask Address..........13 Table 4: Entering Datagram Values ......15 Table 5: Bosch control panels RADXAUX1 and GV2AUX UL Parameters ......
  • Page 4: 1.0 Introduction

    D7412GV2, D7212GV2, D9412G, D7412G, 2.1.1 Conettix System D7212G, D9412, D9112, and D7212 will be Figure 2 shows a Conettix D6600 System using Bosch collectively referred to as “Bosch control panels.” Security Systems, Inc. Control Panels, D9133TTL-E The D9412G, D7412G, D7212G, D9412, Network Interface, D6600, and D6680.
  • Page 5: 3.0 Installation

    Inform the operator and the local authority before installing the D9133TTL-E in an existing system. Disconnect all power to the Mounting Control Panel before installing the The D9133TTL-E can be mounted in one of two D9133TTL-E. ways: The D9133TTL-E has several important features that •...
  • Page 6: Attaching Module To Enclosure Door

    1 - Mounting plate 3. Place the top edge of the D9133TTL-E module 2 - D9133TTL-E Network Interface Module under the facing hook (refer to Detail A) on the plastic standoffs.
  • Page 7: Mounting In A Separate Enclosure

    3.1.3 Mounting in a Separate Enclosure D9133TTL-E with the plastic standoffs and the If so desired, the D9133TTL-E can be mounted in a enclosure mounting brackets. separate enclosure like the AE1 (Grey) or the AE2 4. Insert two screws into the holes and slowly (Red).
  • Page 8: Ethernet Connections

    Ethernet/Serial Status LED Ethernet Connections The D9133TTL-E has four Ethernet/Serial status The RJ45 Jack is used to connect to the D9133TTL-E to LEDs (refer to Figure 12 on page 9), three in the the Ethernet Network (LAN/WAN). The connector center and one in the lower right corner next to the definitions are shown in Figure 10.
  • Page 9: Ip Address Configuration Setup Instructions

    D9133TTL-E | Installation Guide | 5.0 IP Address Configuration Setup Instructions The Network Interface Module (refer to Item Figure 12: Ethernet Status LEDs - Location 3, Figure 3 on page 5) software version must be version 4.5 or higher. To verify the software version, a Telnet session must be initiated.
  • Page 10: Identifying The Mac Hardware Address

    Bosch Security Systems recommends that you read this entire step before beginning. Also, make sure 5.4.1 ARP Command Usage there is power to the D9133TTL-E and the Ethernet 1. Open a DOS window from the Start menu by Network RJ45 connection is in place. →...
  • Page 11: Using Telnet To Finish The Configuration

    D9133TTL-E | Installation Guide | 5.0 IP Address Configuration Setup Instructions Using Telnet to Finish the Configuration If you are using Windows 98, refer to Section 5.5.1 Using Windows 98 Telnet. If you are using Windows 2000 or XP, refer to Section 5.5.2 Using Windows 2000 or XP Telnet...
  • Page 12 9. Press [0] then [ENTER] to set up the basic Server configuration. 7. The message, displays, "Press Enter to go into If the D9133TTL-E Dialer Capture Module has setup mode". been programmed with an IP address in the past, it will be displayed in parentheses.
  • Page 13: Table 3: Netmask Address

    D9133TTL-E | Installation Guide | 5.0 IP Address Configuration Setup Instructions 10. To properly program the IP address Table 3: Netmask Address 190.200.128.219, the following keys would be entered: Number of Netmask 190.200.128.219 [ENTER] Host Bits If using DHCP (Dynamic Host Configuration 255.255.255.254...
  • Page 14: Figure 16: Setting Values In Telnet Session

    15. 16. Press [Enter] to accept the Baud Rate default of (9600). If 9600 is not the default, type 9600 and press [ENTER] to change it. 17. The following information appears: Bosch Security Systems, Inc. | 6/07 | 4998122717-01...
  • Page 15: Figure 17: D9133Ttl-E Encryption

    D9133TTL-E | Installation Guide | 5.0 IP Address Configuration Setup Instructions Software revision of the Network Interface Table 4: Entering Datagram Values Module attached to the D9133TTL-E must be 5.16 or greater, the hardware revision must be CM-E2-RAD to support...
  • Page 16: Using Windows 2000 Or Xp Telnet

    D9133TTL-E | Installation Guide | 6.0 Additional UL Requirements Four reply messages should be received, confirming that the D9133TTL-E is talking to the network. Configuration of the D9133TTL-E Network Interface Module is complete. Perform this procedure for any additional D9133TTL-E’s you may have.
  • Page 17: Table 5: Bosch Control Panels Radxaux1 And Gv2Aux Ul Parameters

    D9133TTL-E | Installation Guide | 6.0 Additional UL Requirements Table 5: Bosch control panels RADXAUX1 and GV2AUX UL Parameters RADXAUX1 Control Panel on Protected Premises UL 1610 Line Security UL 864 Fire GV2AUX (formally Grade AA) System Parameters Intrusion System...
  • Page 18: Ul Listings And Approvals

    D9133TTL-E | Installation Guide | 7.0 UL Listings and Approvals UL Listings and Approvals 8.0 Specifications The D9133TTL-E Network Interface Module is UL Table 6: Specifications Listed as a device. • UL Central Station Burglary (1610), Line 7 in. x 4.5 in.
  • Page 19 D9133TTL-E | Installation Guide | 8.0 Specifications Notes Bosch Security Systems, Inc. | 6/07 | 4998122717-01...
  • Page 20 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450-9199 (800) 289-0096 © 2007 Bosch Security Systems, Inc. 4998122717-01...

Table of Contents