User Manual -USA
Installation Instructions:
DO NOT INSTALL DURING ACTIVE
STORM CONDITIONS.
This device can be used indoor (SPD4tel),
or outdoor when installed in weatherproof
housing(SPD4telkit). Failure to follow
installation instructions can result in personal
injury and/or equipment damage not covered
by warranty.
SPD4tel – For indoor use:
▪
SPD4tel protects 2 pairs (1 pair per
protector module) and is intended for
indoor use only, without additional
housing.
▪
Attach securely to mounting surface.
▪
Install ground wire, and if applicable,
service shield, under top center nut
of mounting bracket and tighten nut
securely.
▪
Connect one pair (tip and ring) under
the bottom nut on each protector
Telco Side Cable
Terminate Between
Washers
Ground Clip
Siemens Industry, Inc.
5400 Triangle Parkway
Norcross, GA 30092
888-333-3545
info.us@siemens.com
2
▪
▪
SPD4telkit – For outdoor use:
▪
▪
▪
▪
▪
Customer Side
Cable
Terminate Between
washers
©2010 Siemens Industry, Inc.
All Rights Reserved. Siemens is a registered
trademark of Siemens AG. Product names
mentioned may be trademarks or registered
trademarks of their respective companies.
Specifications are subject to change without notice.
www.usa.siemens.com/spd
module, tip on one post, ring on the
other.
Connect the customer wiring, tip and
ring, under the top nut on the same
protector module (protector is wired in
parallel)
Check all wiring for loose connections
and shorting or broken wires.
Mount weatherproof housing securely
to flat surface.
Conductors will enter and exit from the
flexible grommet located at bottom of
enclosure.
Follow instruction above for SPD4tel
connections.
Secure enclosure with tie wrap or
similar locking device.
The SPD4telkit is a Parallel Device.