Mount the Chassis
Do not mount the chassis with the rear panel facing downward. This orientation is not supported.
Caution
Step 9
To uninstall the chassis from the wall mount, slide the wall-mounted chassis from the wall, and remove the three screws
from the bottom of the chassis.
What to do next
If you are installing a FIPS cover on the chassis, follow the steps in
Install the cables according to your default software configuration as described in the
Getting Started
Rack-Mount the Chassis
The rack-shelf kit (part number 800-107605-01) contains the following items:
Note
There are two sets of four screws that you can use to secure the chassis to your rack. Chose the screws that
fit your rack.
• Rack shelf (part number 700-122662-01)
• Sliding rack tray (part number 800-107648-01)
• Two cable guides (part number 700-122664-01)
• Six Phillips M3 x 0.5 x 10 mm screws (part number 48-0796-01); use these screws to install the cable
• Six Phillips M3 x 6 mm screws (part number 48-0384-01); use these screws to secure the rack shelf onto
• Four Phillips 12-24 x 0.75 inch screws (part number 48-0440-01); use these screws to secure the
• Four Phillips 10-32 x 0.75 inch screws (part number 48-0441-01); use these screws to secure the
Step 1
Install the cable guides on the sliding rack tray:
Guide.
guides.
the chassis.
sliding-rack tray to your rack.
sliding-rack tray to your rack.
Rack-Mount the Chassis
Install the FIPS Opacity
Shield.
Cisco Firepower 1010
Mount the Chassis
5