SPLIT-TYPE AIR CONDITIONERS
INDOOR UNIT
MSY-GN50VF MSY-GN60VF MSY-GN71VF MSY-GN80VF
For user
OPERATING INSTRUCTIONS
• To use this unit correctly and safely, be sure to read these operating
English
instructions before use.

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric MSY-GN80VF

  • Page 1 SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT MSY-GN50VF MSY-GN60VF MSY-GN71VF MSY-GN80VF For user OPERATING INSTRUCTIONS • To use this unit correctly and safely, be sure to read these operating English instructions before use.
  • Page 2 ● OPERATING INSTRUCTIONS ● ONTENTS I SAFETY PRECAUTIONS I NAME OF EACH PART I PREPARATION BEFORE OPERATION I SELECTING OPERATION MODES I FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT I LONG OPERATION I POWERFUL OPERATION I I-SAVE OPERATION I ECONO COOL OPERATION I TIMER OPERATION (ON/OFF TIMER) I WEEKLY TIMER OPERATION I CLEANING...
  • Page 3: Safety Precautions

    AFETY PRECAUTIONS WARNING Replace all batteries of the remote controller with new ones of the same type. • Using an old battery together with a new one may cause overheat- When the air conditioner does not cool or heat, there is a ing, leakage, or explosion.
  • Page 4: Indoor Unit

    ● OPERATING INSTRUCTIONS ● AME OF EACH PART Indoor unit Remote controller <GN50/60> Signal transmitting Heat exchanger section Distance of signal : Front panel About 6 m Air inlet Air fi lter Beep(s) is (are) heard from the indoor unit when the (Nano plati- signal is received.
  • Page 5: Installing The Remote Controller Batteries

    REPARATION BEFORE OPERATION Before operation: Insert the power supply plug into the power outlet and/or turn the breaker on. Installing the remote controller batteries Press RESET. Remove the front lid. Insert the negative pole of AAA alkaline batteries fi rst. Install the front lid.
  • Page 6: Selecting Operation Modes

    ● OPERATING INSTRUCTIONS ● ELECTING OPERATION MODES I FEEL mode The unit selects the operation mode according to the room temperature when I FEEL is selected. When the room temperature is higher than 25°C, COOL is selected (set temperature: 24°C). When the room temperature is lower than 25°C, DRY is selected.
  • Page 7: Airflow Direction

    AN SPEED AND AIRFLOW DIRECTION ADJUSTMENT Airflow direction (AUTO) ..The vane is set to the most efficient airflow direction. :horizontal position. (Manual) ..For efficient air conditioning, select the upper position for COOL/DRY, and the lower position for FAN. If the lower posi- tion is selected during COOL/DRY, the vane automatically moves to the upward position after 0.5 to 1 hour to prevent any condensation from dripping.
  • Page 8: Save Operation

    ● OPERATING INSTRUCTIONS ● ONG OPERATION SAVE OPERATION Press to start LONG operation. Press during COOL or ECONO COOL mode to • Fan speed increases and the horizontal vane moves to the position for select i-save mode. LONG mode. • Air reaches to longer distance. Set the temperature, fan speed, and airfl...
  • Page 9: Econo Cool Operation

    CONO COOL OPERATION Press during COOL mode page 5 to start ECONO COOL operation. The unit performs swing operation vertically in various cycles according to the temperature of airflow. Press again to cancel ECONO COOL operation. • ECONO COOL operation is cancelled when the VANE, LONG, or POWERFUL button is pressed.
  • Page 10: Weekly Timer Operation

    ● OPERATING INSTRUCTIONS ● EEKLY TIMER OPERATION • A maximum of 4 ON or OFF timers can be set for individual days of the week. • A maximum of 28 ON or OFF timers can be set for a week. Press , and to set ON/OFF, time, and...
  • Page 11: Front Panel

    LEANING Instructions: • Switch off the power supply or turn off the breaker before cleaning. • Do not use water hotter than 50°C. • Be careful not to touch the metal parts with your hands. • Do not use a scrubbing brush, a hard sponge, or the like. •...
  • Page 12: When You Think That Trouble Has Occurred

    ● OPERATING INSTRUCTIONS ● HEN YOU THINK THAT TROUBLE HAS OCCURRED Even if these items are checked, when the unit does not recover from the Symptom Explanation & Check points trouble, stop using the air conditioner and consult your dealer. Does not cool The room cannot be cooled •...
  • Page 13: Specifications

    HEN THE AIR CONDITIONER IS NOT NSTALLATION PLACE AND GOING TO BE USED FOR A LONG TIME ELECTRICAL WORK Installation place Operate by COOL mode with the highest temperature Avoid installing the air conditioner in the following places. set or FAN mode for 3 to 4 hours. Page 5 •...
  • Page 16 HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN JG79Y271H02...