INTRODUCTION OVERVIEW THERMOSTAT CONTROL Display Up/Down Buttons MODE HOLD Cool Off Heat Auto Function Switch Fan Auto/On Switch Mode/Hold Switch PARTS DIAGRAM Up/Down Buttons Display Mode/Hold Switch Wiring Channel Mounting Hole Mounting Hole RESET Reset B G Y W C R 2 “AAA”...
INSTALLATION INSTRUCTIONS WARNING! unplugging the unit or by removing the fuse or switching the appropriate circuit breaker to the OFF position before removing the existing thermostat. PACKAGE CONTENTS/TOOLS REQUIRED Package includes: Thermostat on base, thermostat cover, 2 “AAA” batteries, wiring labels, screws and wall anchors. Tools needed: Drill with 3/16 bit, hammer, screwdriver and putty.
Page 5
TO INSTALL THERMOSTAT (cont.) 1. Turn off power to the heating and cooling system by removing the fuse or switching off the appropriate circuit breaker. 2. Move the Function switch on the thermostat to Off. 3. Remove the cover by inserting and twisting a coin or screwdriver in the slots on the top of the thermostat.
Page 6
INSTALLATION INSTRUCTIONS TO INSTALL THERMOSTAT (cont.) 14. Insert two “AAA” batteries into battery holder. Verify that they are oriented as shown on battery holder. 15. Replace cover on thermostat by snapping it in place. 16. Plug the unit in or turn on power to the system at the main service panel.
Page 7
Table 2: Terminals for six wires 2-stage heat/1-stage cool system (RAK148P2 only) Note: Connect G terminal of thermostat to Zoneline GL terminal for low fan speed or terminal GH for high fan speed. Only one can be selected.
Configuration mode. The configuration mode is used to set the RAK148P2 and RAK164P2 to match the heating/cooling system. These thermostats function with up to 2-stage heat pump systems (RAK148P2 only). To configure the RAK148P2 and RAK164P2, perform the following steps: Note: Operation being set will blink in the display.
Page 9
Set the number of degrees between when stage 1 turns on and stage 2 turns on. Press the button to set differential value. Press the Hold button to advance to the next screen. Note: Default factory setting is 2°F/1°C for each stage. 4.
Operating functions. • In this mode, the thermostat will not turn on the heating or cooling devices (manual fan can operate). • Off is also used to access Setup and Program modes. Cool • In this mode, the thermostat controls the COOL cooling system.
Testing the thermostat. Once the thermostat is installed, it should be thoroughly tested. CAUTION! Do not use air conditioning when the outdoor temperature is below 50 degrees. This can damage the air conditioning system. Note: Before testing the thermostat, move the Fan Auto/On switch to the Auto position.
Page 12
Testing the thermostat. Heat Test 1. Slide Function switch to Heat position. Heat mode screen is displayed. HEAT 2. Adjust set temperature so it is 5 degrees above room temperature. 3. Resistance heat should come on within a few seconds. 4.
Programming. Factory Programming Settings The programmable thermostat comes preprogrammed with the following schedule: MONDAY MORN 6:00 AM DAY 8:00 AM EVE 6:00 PM NITE 10:00 PM through HEAT 70°F HEAT 62°F HEAT 70°F HEAT 62°F SUNDAY COOL 78°F COOL 85°F COOL 78°F COOL...
Page 14
Programming. Program Overview The programmable thermostat has four periods (MORN, DAY, EVE, NITE) that are customizable for each day of the week. Each period will have a set time, heat temperature and cool temperature. The thermostat monitors the day and time, while maintaining the specific conditions that you have chosen for each period in the program.
Page 15
9. Press the Hold button to advance to the next screen parameter. • Heat temperature is displayed (60°F to 85°F) / (15°C to 29°C). HEAT Note: Transitions required after 11:59 PM must be programmed in the next days PROG MORN MORN period.
Page 16
Programming. Use the following personal program schedule to record your settings: MONDAY MORN NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL TUESDAY MORN NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL WEDNESDAY MORN NITE HEAT HEAT HEAT HEAT COOL COOL COOL...
Low battery indicator. The programmable thermostats with battery backup have a low battery warning screen. Low battery warning The thermostat will display a low battery indication. The low battery warning will be flashing until batteries are replaced.
Page 18
Power failure Indicator The programmable thermostats with battery backup also will indicate a main power failure when the 24 VAC power from the room air conditioner is not present. Power failure The thermostat will display a power failure indication (“PF”) on the screen. Note: If “PF”...
Troubleshooting tips. Problem Solution No display Check for 24 VAC at thermostat and batteries; display is blank when 24 VAC is not present and batteries are bad. System fan does not Verify that wiring is correct. come on properly All thermostat buttons Verify that 24 VAC is present;...
Page 21
Problem Solution “PF” displays on screen. Check for 24 VAC at thermostat. Display reads “12:00 PM” Set clock/time. Problem not listed above Press the Reset button once. Reset button function: time, day and mode will be changed to the factory settings.
From the date of the due to a defect in materials or workmanship. original purchase What GE Will Not Cover: Service trips to your location. Improper installation. If you have an installation problem, contact your installer. You are responsible for providing adequate electrical connections to the product.