  • Page 1 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF Euramco Safety Inc. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF Euramco Safety Inc. IS PROHIBITED. Owner's Manual EX150Li HIGH-PERFORMANCE BATTERY FAN San Diego Luxembourg Dubai...
  • Page 2: Table Of Contents

    Warning Labels & Safety Pecautions ..................5 available at the time of printing. Euramco Group, Inc. reserves the right to make changes at Specifications ........................5 anytime without notice. Main Interface ..........................6 Plug Types ............................7 RAMFAN products are warranted against manufacture defect. Failure to properly maintain product will invalidate warranty coverage. Please visit Adjusting Angle ..........................8 www.euramco.com for warranty details. Operational Modes ........................9 AC Operation ........................9 DC Operation ........................9...
  • Page 3: Unit Description

    THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF Euramco Safety Inc. ANY REPRODUCTION IN PART OR WHOLE WITHOUT REVISIONS THE WRITTEN PERMISSION OF Euramco Safety Inc. IS PROHIBITED. EXTENDABLE Model EX150Li 18"/46 cm ZONE REV. DESCRIPTION DATE APPROVED...
  • Page 4: Main Interface

    Main Interface Plug Types Control Panel: The EX150Li is suitable for worldwide applications. A voltage converter is not needed. The unit includes a simple removable cord that allows the unit to operate up to 250 VAC: Mainly used in Type Order # PRESS PRESS FOR ON/OFF BAT. FAULT North and Central America, Japan EL-CUS-4762 NO PWR AC PWR DC PWR France, Belgium, Germany, Austria, the EL-CEU-4762 Intellisense Netherlands (and most European countries) FAULT STORAGE United Kingdom, Ireland, Malta, Malaysia and EL-83070-4762 MODE Singapore, Hong Kong, Nigeria Australia, New Zealand, Papua New Guinea and EL-84040-4762 Argentina China, P.R.C. EL-84640-4762...
  • Page 5: Operational Modes

    2. Status LED Light will automatically turn green, displaying the status “Ventilator is connected on AC Power Supply”. 3. Start the ventilator by using the Speed Control knob to the desired speed. Note: You can keep the batteries on their location without charging the battery. Loosen Battery Indicator Lights will turn off because there is no battery charging when ventilator is running on AC. Tighten 4. When the fan is powered off, Status LED Light will automatically turn off after 1 hour and the battery Indicator Lights will redisplay battery charge level of each battery pack detected. The ventilator will begin charging the battery packs after 60 minutes of idle time. DC Operation Negative tilt bracket Tilt adjustment knob (Accessory) Connection of Battery Pack • Plug the ventilator connector cable (blue) into the battery connector: For confined space rescue operations, you can place the ventilator directly on top of a manhole. Tilt range from -90 to +90 degrees. Note that those positions can direct airflow downward or upward • Set the installation index on the battery with the cable, lining up with the cable connector. • Press the connector lock and rotate the blue piece clockwise (a quarter turn to the right) in the most careful way possible. • Align the edge of the battery pack with holder under the red line where it says, “Align battery EX150Li” and firmly slide the battery in the direction of the arrow as shown in the illustration until a loud click is heard.
  • Page 6: Battery Operation Procedures

    • Be sure to secure the unused battery connector by placing electrical tape over the 40V & 52V contacts. battery packs • When running fan on single battery, operating power is limited to reduce maximum discharge current--extending useful life of battery. interchangeable LB9114 Using Two Batteries • The EX150Li offers a true redundant dual battery system. • When using two batteries of identical charge level, batteries are connected in parallel to increase significantly the total runtime and airflow performance. • When using two battery packs, each pack functions independently and is isolated from the other so that if one pack should fail (open circuit, short-circuit, or become discharged) the other battery will provide power to operate the system. • When using dual batteries, it’s important that both batteries be of the same charge level and ideally of the same age and condition. LB9113 Rev B • It’s normal for one battery to discharge slightly more than the other. This is the nature of a truly redundant isolated battery system.
  • Page 7: Run Time

    Battery Operation Procedures Charging Procedure Make sure the battery pack is connect correctly into the ventilator, as described above in • When AC is disconnected and Speed Control is off (speed = 0), the controller and “Connection of Battery Pack”. battery(s) will enter a sleep mode to conserve the battery power after 60 minutes of no activity. • The next step is to leave the ventilator off. During charging, the battery indicator lights will flash. The battery charge level can be recognized by the number of lights that are • To wake the ventilator, push and hold WAKE | STOP Button on Control Panel. constantly lit. Battery Status LED Light will show white solid for the status. The unit will return to sleep mode if not used within 10 minutes. • If both batteries and AC are connected, the batteries will begin charging after 60 minutes of idle time. If only one single battery is connect, the battery will begin • The ventilator starts at the lower speed = 0. Speed will vary by 11 levels - from 11 charging after 120 minutes of idle time. (highest) to 0 (off). Turn clockwise to increase speed. At level 11 (the highest), if keep turning the control knob clockwise, the speed will not change, it will stay at highest • Indicator lights will show charge state during charging. Charging should complete in speed all the time. To slow down, turn counterclockwise. about 5 hours, with the Battery Status Indicator lights turning green and all the five Fuel Gauge lights (if battery is equipped with gauge) on the battery turning red. Should the Speed Control be turned counterclockwise on during the charge, charging will stop, • If you want to increase the speed, push and hold the MAX Button Ventilator and the ventilator will start. Charging will begin again after 15 min of idle time. Status LED Light will flash white for the status. Remember that this will only work when 2 batteries are connected to the ventilator and when it is operating exclusively on DC •...
  • Page 8: Battery Status Indicator Lights

    Battery Status Indicator Lights The Fuel Gauge On the control panel there are 2 sets of lights: on the top side of the battery lights indicate For batteries equipped with a battery fuel gauge: the charge level in the battery attached to the left side of the ventilator, on the bottom side of the battery lights indicate the charge level in the battery attached to the right side of the The Battery Fuel Gauge provides battery status information using five red LEDs. ventilator. Press the Fuel Gauge button to display the lights. The fuel gauge lights will remain lit for approximately five seconds. PRESS PRESS FOR ON/OFF The numbers represent each LED and the grid is how they're laid out: BAT. FAULT NO PWR AC PWR DC PWR Intellisense FAULT STORAGE MODE If the battery is charging, the green indicator lights will horizontally scroll from left-to- right, turning solid green when the battery is fully charged.
  • Page 9: How To Activate "Storage/Transport Mode

    Storage/Transport Modes AC Power Cord This battery fan was designed to replace corded AC fans, optimizing cordless operations. Lithium-ion cell manufacturers recommend that battery cells be stored at 30% state The AC power cord is designed to be removable for the convenience of those users who of charge (SoC) for best long-term health and stability. Further, IATA (International Air choose to operate cordless. Transport Association) Dangerous Goods Regulations (DGR) state that all lithium-ion batteries must not exceed 30% SoC at time of shipment. The AC power connector is a ”Push-Pull” locking system where the outer (blue) slide must be pulled back, in line with the cable, to securely engage connector. RAMFAN battery-powered fans built with Intellisense E3 controllers are equipped with integrated “Storage/Transport Mode” to make it easy to comply with storage • When AC power is needed, push (blue) connector onto (black) inlet on fan controller. recommendations and transport regulations by automatically discharging installed battery Check that it is securely engaged. pack(s) to 30% SoC. • When disconnecting the AC power cord from fan, pull back on (blue) slide to disengage and gently remove. Store in marked frame position when not in use. PRESS PRESS FOR ON/OFF BAT. FAULT NO PWR CORD AC PWR DC PWR STORAGE Intellisense...
  • Page 10: Lithium-Ion Battery Maintenance Guidelines

    Lithium-Ion Battery Maintenance Guidelines Maintenance and Disposal Battery packs do require routine maintenance and care to maximize their useful life and • DO NOT disassemble the ventilator for maintenance reasons. maintain warranty coverage. Read and follow the guidelines in this manual to safely use your lithium-ion battery packs and achieve battery life span. • Do not loosen screws on control box without contacting Euramco customer service. They are torqued to a setting to achieve water tightness. Overview • Completely unravel power cord and place unit on a flat, stable surface. Clean ventilator According to leading cell manufacturers (LG, Samsung, Panasonic), the estimated life of a periodically to remove accumulated dust or particles from ventilator guards, impeller lithium-ion battery is 500 charge cycles. When stating approximate useful life of a battery blade and heat sink in rear of controller (ribbed). Use only biodegradable detergents. If in units of “charge cycles,” cell manufacturers define this as the point where the battery power washing, avoid controller housing especially gaskets and control panel. capacity (Ah) is reduced to 80% of original. This means battery is not “dead” after 500 charge cycles, but runtime is significantly reduced, and replacement should be considered. • Contact factory for replacement parts and installation instructions. To order spare parts call Euramco Group +1.619.670.9590 or theteam@euramco.com Partial discharge of lithium-ion batteries is fine. There is no “memory effect” and the battery does not need periodic full discharge cycles to prolong life. • Always dispose of your battery pack according to federal, state and local regulations. Storage • Even discharged batteries contain some energy. Before disposing of, use electrical tape to cover the terminals to prevent the battery pack from short circuit. When storing, remove battery packs from fan and store in a dry and cool location. Avoid extreme temperatures.
  • Page 11: Maintenance Schedule

    (2) Check immediately if dropped, or damage may affect water ingress protection. (3) These items should be serviced by your RAMFAN servicing dealer, unless you have the proper tools and are mechanically proficient. Refer to RAMFAN service manual for service procedures.
  • Page 12: Certification

    Performance certified is for installation type A - Free inlet, Free oulet. Performance ratings do not include the effects of appurtenances (accessories). RAMFAN’s fire fighting PPV Series outperforms larger blowers in their class with their precision balanced TurboForce Impellers that maximize airflow. These PPV blowers have proven to be effective in controlling airborne contaminates, replacing interior air, removing heat and supplementing fixed ventilation systems.
  • Page 13 SM-EX150LI REV F1 110121 MADE IN THE USA Use with all LUXEMBOURG MIDDLE EAST – UAE CHINA SINGAPORE US Firefighting 2746 Via Orange Way 1 Rue Edmond Reuter, Jebel Ali FTZ, Dubai No. 128, HeZhou Road, literature 1 Fullerton Road Spring Valley, CA 91978 USA 5326 Contern, Luxembourg Phone: +1 (619) 670-9590 x114 JiaoChuan Street, #02-01 One Fullerton Toll Free: (800) 472-6326 Phone: +352-621377200 Fax: +1 (619) 670-7345 ZhenHai District, Ningbo, China Singapore 049213 Phone: +1 (619) 670-9590 Fax: +352-26008056 theteam@euramcosafety.com 315207 Tel : +65-9773 33 35 Fax: +1 (619) 670-7345 theteam@euramcosafety.com...