Page 2
All product and brand names are the service marks, trademarks, registered trademarks, or registered service marks of their respective owners. Printed in the United States of America. Honeywell reserves the right to change any information in this document at any time without prior notice.
DO NOT ACCEPT VERBAL APPROVALS, BECAUSE THEY ARE NOT VALID. Honeywell never recommends using the PW-6000 or related products for use as a primary warning or monitoring system. Primary warning or monitoring systems should always meet local fire and safety code requirements. The installer must also test the system on a regular basis by instructing the end user in appropriate daily testing procedures.
Customer harmless for any costs or damages including reasonable attorneys' fees which Customer may be required to pay as a result of the defective Product or the negligence of Honeywell, its agents, or its employees.
All Products sold or licensed by Honeywell include a warranty registration card which must be completed and returned to Honeywell by or on behalf of the end user in order for Honeywell to provide warranty service, repair, credit or exchange. All warranty...
For any additional information regarding the compliance of this product to any EU-specific requirements, please contact: Honeywell Security & Communications Honeywell Security - Quality Assurance Dept., Newhouse Industrial Estate Motherwell Lanarkshire ML1 5SB Scotland United Kingdom Tel: +44)0) 1698 738200 Email: UK64Sales@Honeywell.com...
Notices Shipping Instructions Shipping Instructions To ship equipment back to Honeywell, Inc.: 1. Contact the customer service department at 800-323-4576 before returning equipment. When you call please have available: • A description of the problem or reason you are returning the equipment.
Installing the PW-6000 Two-Reader Module Description The PW-6000Two-Reader Module provides support for up to two access control doors by providing connections for Wiegand or Clock/Data type readers, supervised inputs, and relay outputs. You can either mount the board in a rack or open and flat. If you rack-mount the board, only one edge is accessible for wiring;...
6 conductors, 18AWG, 500 feet (150m) max. shield and drain Mechanical Dimension 5.5" (140mm) W x 9" (229mm) L x 1" (25mm) H Weight 12 oz. (340g) nominal Environment Temperature 0°C to +49°C, operating, -55°C to +85°C, storage 0% to 85% RHNC Humidity www.honeywell.com...
Installing the PW-6000 Two-Reader Module Setup Setup Setting Jumpers Table 1: Jumper Settings Jumper Setting Default Selected Port 1 RS-485 EOL terminator is not active Port 1 RS-485 EOL terminator is active Reader 0 Power Terminal provides 5 VDC Reader 0 Power Terminal provides 12 VDC Reader 1 Power Terminal provides 5 VDC...
The input LEDs flash when there is a fault associated with the input. When any relay or input is energized or ON, its corresponding status LED becomes ON also. The LED remains ON for as long as the relay is energized. www.honeywell.com...
Page 17
Installing the PW-6000 Two-Reader Module LED Operation The assignment for each relay status LED is shown in the following table. Table 4: Additional PW6000 Two-Reader Module LEDs LED number Description Reader 0 activity Reader 1 activity Input 0 Input 1 Input 2 Input 3 Input 4...
TR- terminal. By factory default J1 is set open. If this board is the last board on the RS-485 bus, install jumper J1 across both pins (closed). Closing J1 provides the bus termination required. www.honeywell.com...
Installing the PW-6000 Two-Reader Module Wiring Wiring This section presents information on reader wiring, input wiring, and control output wiring. The following figure shows the PW-6000 board and identifies its terminal block pin assignments. Figure 1: PW-6000 Two-Reader Module Wiring: Connectors 1-7 Short Door Status TWO READER BOARD...
Page 20
Figure 2: PW-6000 Two-Reader Module Wiring: Connectors 1, 7-9 For RS-485 Communication Connections, twist the blue pair together and use as the common; Note: use the orange pair as your data pair, observing polarity. Connect the external drain shield to the appropriate earth ground on one end. www.honeywell.com...
Installing the PW-6000 Two-Reader Module Wiring Reader Wiring The following Honeywell reader module numbers have been approved by UL for use with the PW6K1R2: OM40BHONA, OM55BHONA, OP10HONE, OP30HONE, OP40HONE, OP90HONE, OT30HONA, OT31HONA, OT35HONA, and OT36HONA. Each reader port supports a reader with TTL interface. Power to the reader is selectable as 5VDC or 12VDC (pass-through).
The following two circuits are suggested. Locate the protection circuit as close to the load as possible (within 12 inches [30cm]); the effectiveness of the circuit decreases as the distance from the load increases. www.honeywell.com...
Use sufficiently large gauge of wires for the load current to avoid voltage loss. Mounting Options This board can be mounted on-edge in the rack-mount enclosure provided by Honeywell or it can be mounted flat against any surface using standoffs under the mounting holes provided in each of the four corners of this board.
7. Connect communications wiring to the Intelligent Controller. 8. Recheck wiring for correct connections and continuity. 9. When all boards have been installed, connect the power supply cord for proper connections and power. 10.Set up the panel controls using the host software. www.honeywell.com...
PW-6000 2-Reader Input Module Programming Sheet Project Name Location / Country Host IC Board Board Description PW Panel RS485 Port Board Address Location Floor Cabinet Location Tamper Input Connected Powerfail Shunted Termination Jumper J1 Not Active PW-6000 Two-Reader Module Installation Guide, Document 800-01951, Revision C...
Page 26
Input 0 Pin #3 Input 1 Com Pin #4 Relay 0 No Pin #5 Relay 0 Com Pin #6 Relay 0 NC Pin #7 Relay 1 No Pin #8 Relay 1 Com Pin #9 Relay 1 NC Pin #10 www.honeywell.com...
Page 27
PW-6000 2-Reader Input Module Programming Sheet Reader 0 ProWatch Reader 0 (the reader address used in the Pro-Watch hardware setup) VDC Select J2 5 Volt Connected Cable Destination Conductor Cable # Color DC Out ( + ) Pin #1 Red LED Pin #2 Beeper Ctrl Pin #3...
Page 28
Outputs 4 and 5 Connected Cable Destination Conductor Cable # Color Relay 4 NC Pin #1 Relay 4 Com Pin #2 Relay 4 NO Pin #3 Relay 5 NC Pin #4 Relay 5 Com Pin #5 Relay 5 NO Pin #6 www.honeywell.com...