GE DBVH520GJ Dimensions And Installation Information
GE DBVH520GJ Dimensions And Installation Information

GE DBVH520GJ Dimensions And Installation Information

7.0 cu. ft. super capacity frontload gas dryer

Advertisement

DBVH520GJ
GE
7.0 Cu. Ft. Super Capacity Frontload Gas Dryer
®
Dimensions and Installation Information (in inches)
Gas Dryer Rating
120V
60Hz, 6A
Exhaust Options: 3-way via rear, left, and bottom.
Circuit Requirements: An individual, properly grounded
branch circuit, protected by a 15-20 amp circuit breaker
or a time-delay fuse, is required.
Note: Dryer wall outlet must be located within 36"
of service cord entry and accessible when dryer is
mounted in position.
Installation Information: For complete information, see
installation instructions packed with your dryer.
For answers to your Monogram,
GE Profile
®
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
800.626.2000.
or
service,
27
31-1/8
Specification Revised 8/09
1-5/8
41-1/2
3-3/4
5-1/2
360461

Advertisement

loading

Summary of Contents for GE DBVH520GJ

  • Page 1 Installation Information: For complete information, see installation instructions packed with your dryer. For answers to your Monogram, GE Profile ® ™ ® appliance questions, visit our website at ge.com or call GE Answer Center service, ® 800.626.2000. 31-1/8 Specification Revised 8/09 1-5/8 41-1/2...
  • Page 2 0" either side, 3" front and rear • Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52". • C loset doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. • N o other fuel-burning appliance shall be installed in the same closet with a gas dryer.
  • Page 3 (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed Down. For more information on venting kits and accessories, please call 1-800-GE-CARES. Best performance Maximum length of 4" dia. rigid metal duct Exhaust hood type Number 90°...
  • Page 4 DBVH520GJ 7.0 Cu. Ft. Super Capacity Frontload Gas Dryer ® Features and Benefits • 7.0 Cu. Ft. Super Capacity - Handles large-size items and family-size loads • S ensor Dry Plus - Continually monitors moisture levels to help clothes look ™ better longer • Rotary Electronic Controls with Cycle Countdown Display and LED Indicators - Simplify the cycle selection and provide accurate cycle times • Interior Dryer Light - Lets you see everything inside for easy loading and unloading • Quiet-By-Design - Engineered for quiet operation ™...

This manual is also suitable for:

Dbvh520gjww