Multi V 5
Cooling Only
1. Specifications
Combination Unit
Model Name
Independent Unit
Cooling (Norminal)
Capacity
Cooling (Rated)
Cooling (Norminal)
Input
Cooling (Rated)
EER (Norminal)
EER (Rated)
Power Factor
Rated
Color
Exterior
RAL (Classic)
Heat Exchanger
Type
Piston Displacement
Number of Revolution
Compressor
Motor Output x Number
Starting Method
Oil Type
Type
Motor Output x Number
Fan
Air Flow Rate(High)
Drive
Discharge
Liquid
Pipe
Connctions
Gas
Dimensions(W x H x D)
Net Weight
Sound Pressure Level (Cooling)
Sound Power Level (Cooling)
High pressure protection
Protection
Compressor/Fan
Devices
Inverter
Communication Cable (VCTF-SB)
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And "Electric characteristics" chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 9614 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Sound values of combination model are calculated values based on sound results of independent models.
Sound values can be increased owing to ambient or installation conditions during operation.
Sound values of system [dB(A)] = 10*log [10^(A1/10)+ ... +10^(An/10)] , A1~An means sound values of independent models.
6. Performances are based on the following conditions :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
7. *** : The number in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160~200%).
The recommended ratio is 130%.
8. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)
56
RT
Btu/h
kW
Btu/h
kW
kW
kW
-
3
cm
/rev
rev/min
W x No.
W
3
m
/min
3
ft
/min
Side / Top
mm(inch)
mm(inch)
mm
inch
kg
lbs
dB(A)
dB(A)
No.×㎟
40
ARUV480DTE5
ARUV241DTE5
ARUV241DTE5
480,000
140.6
444,000
130.2
38.40
34.80
3.66
3.74
0.93
Morning Gray / Dawn Gray
RAL 7030 / RAL 7037
Wide Louver Plus
Hermetically Sealed Scroll
62.1 × 4
3,600 × 4
5,300 × 4
Inverter
FVC68D(PVE)
Propeller fan
900 × 4
320 × 2
11,301 × 2
DC INVERTER
TOP
19.05(3/4)
41.3(1-5/8)
(1,240 × 1,690 × 760) × 2
(48-13/16 × 66-17/32 × 29-29/32) × 2
276 × 2
608 × 2
68.0
91.0
High pressure sensor / High pressure switch
Over-heat protection / Fan driver overload protector
Over-heat protection / Over-current protection
2C × 1.0 ~ 1.5
Outdoor Units
42
ARUV504DTE5
ARUV241DTE5
ARUV144DTE5
ARUV121DTE5
504,000
147.7
474,000
138.9
38.03
34.91
3.88
3.98
0.93
Morning Gray / Dawn Gray
RAL 7030 / RAL 7037
Wide Louver Plus
Hermetically Sealed Scroll
62.1 × 4
3,600 × 4
5,300 × 4
Inverter
FVC68D(PVE)
Propeller fan
(900 × 4) + (1,200 × 1)
(320 × 2) + (240 × 1)
(11,301 × 2) + (8,476 × 1)
DC INVERTER
TOP
19.05(3/4)
41.3(1-5/8)
(1,240 × 1,690 × 760) × 2
+ (930 × 1,690 × 760) × 1
(48-13/16 × 66-17/32 × 29-29/32) × 2
+ (36-5/8 × 66-17/32 × 29-29/32) × 1
(276 × 1) + (220 × 1) + (188 × 1)
(608 × 1) + (485 × 1) + (414 × 1)
67.0
89.4
2C × 1.0 ~ 1.5