Honeywell TemaLine TemaKey Installation Manual
Honeywell TemaLine TemaKey Installation Manual

Honeywell TemaLine TemaKey Installation Manual

Modular terminal

Advertisement

Quick Links

Modular Terminal
Modular Terminal
Modular Terminal
Modular Terminal
Installation Manual
Installation Manual
Installation Manual
Installation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell TemaLine TemaKey

  • Page 1 Modular Terminal Modular Terminal Modular Terminal Modular Terminal Installation Manual Installation Manual Installation Manual Installation Manual...
  • Page 2: Table Of Contents

    Modular terminal TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS FCC NOTICE................4 PRELIMINARY OPERATIONS PRELIMINARY OPERATIONS PRELIMINARY OPERATIONS PRELIMINARY OPERATIONS ................5 5 5 5 ......Mounting Instructions .............. 5 Arranging the Cable Tubes and Junction Boxes ......6 Cabling: Recommendations ..........
  • Page 3: Fcc Notice

    TECHNICAL DATA TECHNICAL DATA ................24 TECHNICAL DATA TECHNICAL DATA ................ Summary of Modular Devices........... 24 RTU-B07 (Proxy Reader for HID Cards) ........25 RTU-C01 (Alphanumeric LCD Module) ........26 RTU-C02 (Graphic LCD Module) ..........27 RTU-T01 (Numeric Keyboard Module)........
  • Page 4: Preliminary Operations Preliminary Operations

    PRELIMINARY OPERATIONS Mounting Instructions Mounting Instructions Mounting Instructions Mounting Instructions The cables are attached to an encased box. Make sure that you place the box at a height of 120cm from the floor (see Figure 1). tube cables floor Figure 1: Space requirements for mounting Mounting Instructions Page 5...
  • Page 5: Arranging The Cable Tubes And Junction Boxes

    Arranging the Cable Tubes and Junction Arranging the Cable Tubes and Junction Arranging the Cable Tubes and Junction Arranging the Cable Tubes and Junction Boxes Boxes Boxes Boxes All the cables consist of 4 wires that must be connected in parallel from one node to the next.
  • Page 6 If you want to mount the tubes on the surface of the walls, it is advisable to place the junction boxes under each terminal (see example in Figure 3). Figure 3: Location of the junction boxes Arranging the Cable Tubes and Junction Boxes Page 7...
  • Page 7: Electrical Connections

    Electrical Connections Electrical Connections Electrical Connections Electrical Connections The RTU is powered at low voltage (12V 120mA) by a battery- operated power supply module (RTU-Qxx). When determining the correct size for power cables, refer to the table below. Type of cable Length (m) in relation to effective load ohm/Km 100 [mA] 200 [mA] 500 [mA] 1 [A]...
  • Page 8: Lonworks Data Cables

    L L L L Data Cables Data Cables Data Cables Data Cables ORKS ORKS ORKS ORKS • The L data cable must be twisted pair ORKS • In a free topology configuration, the sum total of the sections must not exceed 500m •...
  • Page 9 • The FTT10A Echelon v1.2 User Guide recommends the cables indicated in Table 2. Manufacturer and Connection to bus - Connection in free topology – model maximum total length [m] maximum node-node length max. [m] Belden 85102 2700 Belden 8471 2700 Level IV (twisted pair, 1400...
  • Page 10: Mounting The Unit On The Wall

    Mounting the Unit on the Wall Mounting the Unit on the Wall Mounting the Unit on the Wall Mounting the Unit on the Wall Horizontal Assembly – Single Module Horizontal Assembly – Single Module Horizontal Assembly – Single Module Horizontal Assembly – Single Module To assemble the unit in a horizontal position, follow these steps: 1.
  • Page 11: Horizontal Assembly - Triple Module

    Horizontal Assembly – Triple Module Horizontal Assembly – Triple Module Horizontal Assembly – Triple Module Horizontal Assembly – Triple Module To assemble the unit in a horizontal position, follow these steps: 1. Drill two holes in the wall (to accommodate the 2 plastic dowels), so that the frame will cover the hole through which the cables pass.
  • Page 12: Combined Assembly - Single And Triple Modules

    Combined Assembly - Single and Triple Modules Combined Assembly - Single and Triple Modules Combined Assembly - Single and Triple Modules Combined Assembly - Single and Triple Modules A combined wall assembly of single and triple modules allows you to create units consisting of 2, 4 and 5 units.
  • Page 13 NET1 NET2 Attachment Attachment +12V clip clip NET1 NET2 +12V Figure 7: Combined assembly of single and triple module wall units Mounting the Unit on the Wall Page 14...
  • Page 14: Fastening The Cables

    Fastening the Cables Fastening the Cables Fastening the Cables Fastening the Cables Fasten the cable clamps to the cable bar so that the cables are arranged towards the inside of the frame (see Figure 8). CONNECTIONS NET1 (green) NET2 (yellow) GND (black) +12V (red) Figure 8: Fastening the cables...
  • Page 15: Vertical Assembly

    Vertical Assembly Vertical Assembly Vertical Assembly Vertical Assembly To assemble the unit in a vertical position, follow these steps: 1. Drill two holes in the wall (to accommodate the 2 plastic dowels), so that the frame will cover the hole through which the cables pass.
  • Page 16: Channeling The Cables From The Bottom Of The Box

    Channeling the Cables from the Bottom of the Box Channeling the Cables from the Bottom of the Box Channeling the Cables from the Bottom of the Box Channeling the Cables from the Bottom of the Box As an alternative, you can channel the cables so that they exit from the bottom of the frame.
  • Page 17: Installation Installation

    INSTALLATION Combining the Modules Combining the Modules Combining the Modules Combining the Modules Each TemaKey consists of one or more RTU modules that must be positioned and connected to their respective wall attachment frames (RTU-Sxx) as indicated in the table below. Reader Reader Reader...
  • Page 18: Terminals

    Terminals Terminals Terminals Terminals Code Grouping Horizontal Vertical Notes TK-D07 1 x RTU-C01 Weight=0.9Kg 1 x RTU-B07 Power=2.7W 2 x RTU-S01 Current=200mA Code Grouping Horizontal Vertical Notes TK_T09 1 x RTU-C01 Weight=1.15Kg 1 x RTU-B07 Power=3.1W 1 x RTU-B01 Current=230mA 1 x RTU-S03 Terminals with Keyboards Terminals with Keyboards...
  • Page 19: Interactive Terminals

    Interactive Terminals Interactive Terminals Interactive Terminals Interactive Terminals Code Grouping Horizontal Vertical Notes TK-D27 1 x RTU-C02 Weight=1.25Kg 1 x RTU-B07 Power=6W 1 x RTU-S03 Current=440mA Interactive Terminals with Keyboards Interactive Terminals with Keyboards Interactive Terminals with Keyboards Interactive Terminals with Keyboards Code Grouping Horizontal...
  • Page 20: Attaching The Modules To The Wall

    Attaching the Modules to the Wall Attaching the Modules to the Wall Attaching the Modules to the Wall Attaching the Modules to the Wall All tEmaline modules are equipped with a simple attachment mechanism; the module clicks into position without the need for tools. To attach the module to the frame, follow these steps: 1.
  • Page 21: Applying The Entry/Exit Labels

    Applying the Entry/Exit Labels Applying the Entry/Exit Labels Applying the Entry/Exit Labels Applying the Entry/Exit Labels Apply the two entry/exit labels to the magnetic reader according to the pre-configured transit direction. Make sure that you place the labels in the appropriate hollows (see details in Figure 12 and Figure 13).
  • Page 22: Identification Via Bar Code

    Identification via Bar Code Identification via Bar Code Identification via Bar Code Identification via Bar Code The components enclosed in the packaging include a bar code label. The person responsible for installing the terminal must apply this label to the corresponding identification form, and indicate the location of the terminal in the appropriate box (see example in Table 3).
  • Page 23: Technical Data

    TECHNICAL DATA Summary of Modular Devices Summary of Modular Devices Summary of Modular Devices Summary of Modular Devices This section contains technical data regarding the modular devices: • RTU-B07 (Reader module for HID proxy cards) • RTU-C01 (Alphanumeric LCD module) •...
  • Page 24: Rtu-B07 (Proxy Reader For Hid Cards)

    RTU-B07 RTU-B07 RTU-B07 RTU-B07 (Proxy Reader for HID Cards) for HID Cards) for HID Cards) for HID Cards) Code 1520145 Parameter Parameter Parameter Parameter Value Value Value Value DC power supply ±15% 60mA Weight 0.30 Kg Dimensions 72 x 160 x 52 mm IP55 IP Protection Rating Operating temperature...
  • Page 25: Rtu-C01 (Alphanumeric Lcd Module)

    RTU-C01 RTU-C01 RTU-C01 RTU-C01 (Alphanumeric LCD Module) Alphanumeric LCD Module) Alphanumeric LCD Module) Alphanumeric LCD Module) Code 1500105 Parameter Parameter Parameter Parameter Value Value Value Value DC power supply ±15% 140mA (nominal) 70mA (backlight off) Weight 0.30 Kg Dimensions 72 x 160 x 52 mm IP Protection Rating IP55 0-50 °C...
  • Page 26: Rtu-C02 (Graphic Lcd Module)

    RTU-C02 RTU-C02 RTU-C02 RTU-C02 (Graphic LCD Module) Graphic LCD Module) Graphic LCD Module) Graphic LCD Module) Code 1500101 Parameter Parameter Parameter Parameter Value Value Value Value DC power supply ±15% 380mA (nominal), 140mA (backlight off) Weight 0.65 Kg Dimensions 166 x 190 x 52 mm IP Protection Rating IP55 0-50 °C...
  • Page 27: Rtu-T01 (Numeric Keyboard Module)

    RTU-T01 RTU-T01 RTU-T01 RTU-T01 (Numeric Keyboard Module) ) ) ) Code 1500104 Parameter Parameter Parameter Parameter Value Value Value Value DC power supply ±15% 30mA (nominal), 50mA (max) Weight 0.25 Kg Dimensions 72 x 160 x 52 mm IP Protection Rating IP55 0-50 °C Operating temperature...
  • Page 28: Optional Parts

    Optional Parts Optional Parts Optional Parts Optional Parts Unlocking tool code 3900695AB Optional Parts Page 29...
  • Page 29 This page is intentionally left blank Optional Parts Page 30...
  • Page 30 This page is intentionally left blank Optional Parts Page 31...
  • Page 31 This page is intentionally left blank...
  • Page 32 gçìÑëçÑìX>áììèXMMñññLìÑåÄãàçÑLÇéå...