Page 1
Original instructions Spot Safety light beam ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/lowvoltage...
Page 2
DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of ABB/JOKAB SAFETY for any act exceed the individual price of the product on which liability asserted.
In case of functional problems .......................... 14 Operation ............................15 LED indication..............................15 Model overview ..........................16 Available models .............................. 16 Accessories ..............................16 Technical data ........................... 17 Dimensions ..............................18 EC Declaration of conformity ......................20 2TLC172178M0201, rev. D www.abb.com/lowvoltage 2011-11-15...
This document is intended for authorized installation personnel. Prerequisites It is assumed that the reader of this document has knowledge of the following: Basic knowledge of ABB/Jokab Safety products. Knowledge of safety devices and safety light beams. Knowledge of machine safety.
The light beam is available in two versions: Spot 10 for distances up to 10 m and Spot 35 for up to 35 m. The light beams can be mounted at different heights and be angled around a machine using ABB/Jokab Safety mirrors and brackets.
Coded pulse transmission Coded pulse transmission 24 VDC This supply does not need to be the same as connected to the Vital 1 Coded pulse transmission Vital 1 safety module can accommodate up to 6 Spot systems 2TLC172178M0201, rev. D www.abb.com/lowvoltage 2011-11-15...
Warning! The information output signal is non-failsafe and must therefore never be used to control a safety application. Connection examples Connection example – Connection of Spot T/R to Vital 1 2TLC172178M0201, rev. D www.abb.com/lowvoltage 2011-11-15...
Page 8
Connection example – Vital 1 with three light beams Spot 2TLC172178M0201, rev. D www.abb.com/lowvoltage 2011-11-15...
850 mm from the light beams. When determining the correct safety distance the stopping time of the machine and the risk level must be taken into account (see also EN 13855). Contact ABB/Jokab Safety for further information. Accessories and mounting The Spot light beam can be mounted using a variety of brackets, posts and mirrors.
Page 10
Additional measures may be necessary to ensure that the Spot T/R unit does not fail to danger when other forms of light radiation are present in a particular application (for example, use of cable-less control devices on cranes, radiation from weld spatter or effects from stroboscopic lights). 2TLC172178M0201, rev. D www.abb.com/lowvoltage 2011-11-15...
Transmitter 1 Receiver 1 Transmitter 2 Receiver 2 Spot T Spot R Spot T Spot R Allowed Wall Receiver 1 Transmitter 1 Transmitter 2 Receiver 2 Allowed Spot R Spot T Spot T Spot R 2TLC172178M0201, rev. D www.abb.com/lowvoltage 2011-11-15...
Page 12
Worst case Transmitter 1 Receiver 1 Spot T Spot R Table 2 0.44 m 10 m 0.87 m Transmitter 2 Receiver 2 20 m 1.75 m Spot T Spot R = 2.5 35 m 3.06 m 2TLC172178M0201, rev. D www.abb.com/lowvoltage 2011-11-15...
Page 13
= L × tan ( ) where x = minimum distance between Spot and reflective surface L = distance between transmitter and receiver = maximum spreading angle of light disturbance NB: Example values are given in Table 3 2TLC172178M0201, rev. D www.abb.com/lowvoltage 2011-11-15...
(EN 62061:2005). In case of breakdown or damage to the product, contact the nearest ABB/Jokab Safety Service Office or reseller. Do not try to repair the product yourself since it may accidentally cause permanent damage to the product, impairing the safety of the device which in turn could lead to serious injury to personnel.
LED indication Indication Description LED on transmitter Green Power supply OK Green Alignment OK, safety circuit closed LED on receiver Green (flash) Alignment OK, safety circuit opened before this unit Beam interrupted, safety circuit open 2TLC172178M0201, rev. D www.abb.com/lowvoltage 2011-11-15...
Transmitter only. Part of Spot 35 T/R. Maximum distance 35 m. Spot 10 R 2TLA020009R2500 Receiver only. Part of Spot 10 T/R. Maximum distance 10 m. Spot 35 R 2TLA020009R2600 Receiver only. Part of Spot 35 T/R. Maximum distance 35 m. Spot 10...
Technical data Manufacturer Address ABB AB / JOKAB SAFETY Varlabergsvägen 11 SE-434 39 Kungsbacka Sweden Power supply Operating voltage 17-27 VDC, ripple ± 10 % (SELV/PELV) Current consumption Transmitter: < 25 mA Receiver: < 15 mA Output currents Information output: Max. 10 mA Dynamic signal output: Max.
Performance level: PL e, Category 4 : 1.14*10 EN 954-1 Category 4 EN 61496 Type 4 (in combination with Vital 1) Certifications TÜV Nord Dimensions Spot 10T 61.6 Trim potentiometer (radiant power adjustment) (indication) Spot 10 R 61.6 (indication) 2TLC172178M0201, rev. D www.abb.com/lowvoltage 2011-11-15...