Turn compressor casing (72000) together with wall insert and dif-
u
fuser and set them down with surface (F) on underlay.
WARNING
Tipping the compressor casing
Make sure that the underlay does not slip.
Allow compressor casing to rest only on surface (F).
u
Check the underlay and adjust it if necessary.
u
Remove the screw (72002).
u
Remove the diffuser (79000).
u
Carefully press off the wall insert (77000) using the press-off screws
u
(90900) and remove it using the swivel lifting eye (90230).
Remove the O-rings (77005 & 77006).
u