AIR CONDITIONER (MULTI-SPLIT TYPE)
Installation Manual
Outdoor Unit
Model name:
RAS-2M10U2AVG-E
RAS-2M14U2AVG-E
RAS-2M18U2AVG-E
RAS-3M18U2AVG-E
* NOTE:
Descriptions about operations for the 3 indoor units in
this manual are not applicable to RAS-2M10U2AVG-E,
RAS-2M14U2AVG-E and RAS-2M18U2AVG-E.
Installation Manual
Outdoor Unit
R32
English

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAS-2M18U2AVG-E

  • Page 1 AIR CONDITIONER (MULTI-SPLIT TYPE) Installation Manual Outdoor Unit Model name: RAS-2M10U2AVG-E RAS-2M14U2AVG-E RAS-2M18U2AVG-E RAS-3M18U2AVG-E * NOTE: Descriptions about operations for the 3 indoor units in this manual are not applicable to RAS-2M10U2AVG-E, RAS-2M14U2AVG-E and RAS-2M18U2AVG-E. Installation Manual English Outdoor Unit...
  • Page 2: Table Of Contents

    Outdoor Unit Installation Manual Contents Precautions for safety ................... 2 Installation / service tools .
  • Page 3: Precautions For Safety

    Outdoor Unit Installation Manual Precautions for safety The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual. Be sure to read this installation manual carefully before installing. The supplied CD-ROM contains the installation manual translated into many languages. Recommend to the owner to perform maintenance periodically when using over long periods of time.
  • Page 4 Outdoor Unit Installation Manual For general public use Power supply cord of parts of appliance for outdoor use shall be at least polychloroprene sheathed fl exible cord (design H07RN-F) or cord designation 60245 IEC66 (1.5 mm² or more). (Shall be installed in accordance with national wiring regulations.) This appliance is not intended for use by person (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for...
  • Page 5 Outdoor Unit Installation Manual DANGER • THE MANUFACTURER SHALL NOT ASSUME ANY LIABILITY FOR THE DAMAGE CAUSED BY NOT OBSERVING THE DESCRIPTION OF THIS MANUAL. • FOR USE BY QUALIFIED PERSONS ONLY. • MEANS FOR DISCONNECTION FROM THE SUPPLY HAVING A CONTACT SEPARATION OF AT LEAST 3 MM IN ALL POLES MUST BE INCORPORATED IN THE FIXED WIRING.
  • Page 6 Outdoor Unit Installation Manual WARNING About the refrigerant • This product contains fl uorinated greenhouse gases. • Do not vent gases to the atmosphere. • The appliance shall be stored in a room without continuously operating ignition sources (for example: open fl ames, an operating gas appliance or an operating electric heater). •...
  • Page 7 Outdoor Unit Installation Manual WARNING • Do not use any refrigerant different from the one specifi ed for complement or replacement. Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or an injury to your body. •...
  • Page 8 Outdoor Unit Installation Manual WARNING • Installation work must be performed following the instructions in this installation manual. Improper installation may cause water leakage, electrical shock or fi re. Check the following items before operating the unit. - Be sure that the pipe connection is well placed and there are no leaks. - Check that the service valve is open.
  • Page 9 Outdoor Unit Installation Manual CAUTION • Please read this installation manual carefully before installing the unit. It contains further important instructions for proper installation. • Exposure of unit to water or other moisture before installation could result in electric shock. Do not store it in a wet basement or expose to rain or water. •...
  • Page 10: Installation / Service Tools

    20 (RAS-2M10U2AVG-E) 26 (RAS-2M14U2AVG-E) Total — 32 (RAS-2M18U2AVG-E) 36 (RAS-3M18U2AVG-E) All combinations that do not exceed the “Total” number can be installed. 2 or more indoor units must be connected to an outdoor unit. When 2 indoor units are connected to an outdoor unit, note that some combinations of indoor units are not compatible.
  • Page 11: Installation Of Outdoor Unit

    Outdoor Unit Installation Manual Draining Off the Water from the Outdoor Unit Installation of outdoor unit Install 2 waterproof rubber caps and the drain nipple to drain off the Installation Location water from the outdoor unit. • Seal the knock-out holes and screw/thread areas tightly using a silicon •...
  • Page 12: Refrigerant Piping

    Outdoor Unit Installation Manual Pipe connection Refrigerant piping 1. Make wire and pipe connections for each indoor unit separately. 2. Align the centres of the connecting pipes and tighten the fl are nut as much CAUTION as possible with your fi ngers, then tighten the nut using a torque wrench. Be sure to tighten the nut at the specifi...
  • Page 13: Electrical Work

    Outdoor Unit Installation Manual Performing Additional Installation of an Indoor Unit 4. Disconnect the charge hose from the service port, then open the valve stem fully using a 4 mm hexagon wrench. 1. Collect refrigerant from the outdoor unit. 2. Turn off the circuit breaker. Service port cap Hexagon wrench is 3.
  • Page 14: Grounding

    • If the air conditioner is not grounded, users may receive an electric shock RAS-2M14U2AVG-E if they touch the surface of the outdoor unit and that unit is charged with Model RAS-2M10U2AVG-E RAS-3M18U2AVG-E RAS-2M18U2AVG-E static. Power supply 1ph, 50Hz, 220-240V Maximum running Test run 12.3A...
  • Page 15 Outdoor Unit Installation Manual Gas Leak Inspection 3. Turn on the circuit breaker to supply electricity. In the initial LED display status, D805 is lighted as below. Refer to the “ Gas Leak Inspection” on page 12. : ON, : OFF, : Rapid Flashing (5 times/sec.), ™...
  • Page 16: Pump-Down Operation

    Outdoor Unit Installation Manual 4. Hold down SW01 for at least 5 seconds, and check that D800 is lighted Pump-down Operation and D804 light is fl ashing (1 time/sec.). Pump-down Operation (Recovering refrigerant) D800 D801 D802 D803 D804 D805 ™ ˜...
  • Page 17: Appendix

    Outdoor Unit Installation Manual...