Internal Use Only Room Air Conditioner SVC MANUAL(Exploded View) MODEL : LT0816CER LT0816CERY7 CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.
1.4 FEATURES • Designed for cooling only. • Side air-intake, side cooled-air discharge. • Powerful and quiet cooling. • Built in adjustable THERMISTOR and THERMOSTAT. • Top-down chassis for the simple installation and service. • Washable one-touch filter. • Compact size. 1.5 CONTROL LOCATIONS 1.5.1 COOLING ONLY MODEL •...
2. DISASSEMBLY INSTRUCTIONS — Prior to disassembling the unit, make sure that the POWER is off and the power cord is unplugged from the wall receptacle. 2.1 MECHANICAL PARTS 2.1.1 FRONT GRILLE 1. Open the inlet grille downward. 2. Remove the screw which fastens the front grille. 3.
2.2 AIR HANDLING PARTS 2.2.1 ORIFICE, AND TURBO FAN 1. Remove the front grille. (Refer to section 2.1.1) 2. Remove the cabinet. (Refer to section 2.1.2) 3. Remove the 2 screws which fasten the evaporator at the left side and the right side. (See Fig.
2.2.3 SHROUD 1. Remove the fan. (Refer to section 2.2.2) 2. Remove the shroud. (See Fig. 9) 3. Re-install the components by referring to the removal procedures, above. 2.3 ELECTRICAL PARTS 2.3.1 MOTOR 1. Remove the cabinet. (Refer to section 2.1.2) Figure 9 2.
2.3.4 POWER CORD 1. Remove the control box. (Refer to section 2.1.3) 2. Unfold the control box. (Refer to section 2.3.3) 3. Disconnect the grounding screw from the Base pan. 4. Disconnect 2 receptacles. 5. Remove a screw which fastens the clip cord. 6.
2.4 REFRIGERATION CYCLE CAUTION Discharge the refrigerant system using a Freon Recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon . Leave the valve in place after servicing the system.
Page 10
NOTES — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to 6. Recharge as follows : discharge the refrigerant system using a Freon 1) Refrigeration cycle systems are charged from the recovery System. High-side. If the total charge cannot be put If there is no valve to attach the recovery system, in the High-side, the balance will be put in the install one (such as a WATCO A-1) before venting...
Page 11
Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pinch-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve. Figure 17A-Pulling Vacuum Figure 17B-Charging —12—...
3. INSTALLATION 3.1 INSTALLATION REQUIREMENTS INSTALLATION HARDWARE If you use an existing wall sleeve, you should measure its dimensions. Install the new air conditioner according to these installation instructions to achieve the best performance. All wall sleeves used to mount the new air conditioner must be in good 2 Size options structural condition and have a compatible rear grille in order to securely attach the new air conditioner.
3.2 INSTALLATION NOTE: All wall sleeves used to mount the new Air Conditioner must be in sound structural condition and have a CAUTION rear grille that securely attaches to sleeve, or rear flange that serves as a stop for the Air Conditioner. Installing the FRIEDRICH USC sleeve ensures Remove old air conditioner from existing wall sleeve.
PROCEDURE Install the new unit into the wall sleeve. If you are using the new sleeve (optionally supplied with your unit),skip to step 3. Toassembletrim,tpthetabofeachpiece Otherwise, install the plastic grille from the kit. into the slot of the other piece as shown below. Cut the plastic grille to 25-1/2"...
PROCEDURE B Remove the backing from the Vertical Insulation strip 15 and attach that to the Redirect the louvers at the back of the wall inside right of the sleeve as shown below. sleeve to 60° angle as shown in the FIG 8. The Remove the backing from the Around Insulation use of pliers is recommended.
Page 16
PROCEDURE B CONTINUED Remove the backing from the support blocks and attach them to the inside of the wall sleeve as shown FIG 29. Slide the baffle into slots of the support blocks. " Wall Wall Baffle Sleeve Front Support Block FIG.
3.5 PROCEDURE C Remove the backing from the Horizontal Insulation strip 7 / 32 3 / 8 3 / 16 and attach that to the inside right of the Redirect the louvers at the back of the wall sleeve to 60° sleeve as shown below.
Page 18
PROCEDURE C CONTINUED CAUTION To achieve rearward slope for unit draining, • Air conditioners covered in this manual pose an remove the backing from the 11 " shim 13 / excessive weight hazard. Two or more people are strips and attach them as shown below in Fig. 37.
4. TROUBLESHOOTING GUIDE 4.1 OUTSIDE DIMENSIONS 24" " (499mm) (610mm) Cool F1 LOW Energy F2 MED F3 HIGH Saver TEMP Timer MODE TIMER POWER SPEED 4.2 PIPING SYSTEM CONDENSER COILS CAPILLARY TUBE MOTOR COMPRESSOR TURBO FAN EVAPORATOR COILS Following is a brief description of the important components and their functions in the refrigeration system. Refer to Fig.
4.3 TROUBLESHOOTING GUIDE In general, possible trouble is classified in two causes. The one is called Starting Failure which is caused from an electrical defect, and the other is Ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application. Unit is running but cooling is ineffective Ineffective Cooling Check cold air circulation...
Page 21
Fails to Start Check power source. Check circuit breaker and fuse. Check control switch Gas leakage at feeler bulb setting. of thermostat Check control switch. Only compressor fails to Only fan fails to start. start. Improper wiring. Drop in power voltage. Improper thermostat setting Defect of fan motor capacitor.
Page 22
COMPLAINT CAUSE REMEDY Fan motor will not run. No power Check voltage at outlet. Correct if none. Power supply cord Check voltage to rotary switch. If none, check power supply cord. Replace cord if circuit is open. Rotary switch Check switch continuity. Refer to wiring diagram for terminal identification.
Page 23
COMPLAINT CAUSE REMEDY Compressor will not run, Voltage Check voltage. See the limits on the preceding. but fan motor runs. page. If not within limits, call an electrician. Wiring Check the wire connections, if loose, repair or replace the terminal. If wires are off, refer to wiring diagram for identification, and replace.
Page 24
REMEDY COMPLAINT CAUSE Compressor cycles Voltage Check the voltage. See the limits on the preced- on overload. ing page. If not within limits, call an electrician. Overload Check overload, if externally mounted. Replace if open. (If the compressor temperature is high, remove the overload, cool, and retest.) Fan motor If not running, determine the cause.