Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
LG Manuals
Air Conditioner
R1003A3
Svc manual
LG R1003A3 Svc Manual
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
page
of
26
Go
/
26
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
Preface
Safety Precautions
Insulation Resistance Test
Specifications
Features
Control Locations
Disassembly Instructions
Mechanical Parts
Front Grille
Cabinet
Control Box
Air Handling Parts
Air Guide and Blower
Fan and Shroud
Electrical Parts
Overload Protector
Compressor
Capacitor
Power Cord
Thermostat
Rotary Switch
Motor
Refrigeration Cycle
Condenser
Evaporator
Capillary Tube
Installation
Select the Best Location
Check of Installation
How to Drain
How to Install
How to Use the Reversible Inlet Grille
Outside Dimensions
Piping System
Troubleshooting Guide
Schematic Diagram
Circuit Diagram
Exploded View
Advertisement
Quick Links
Download this manual
Internal Use Only
http://biz.lgservice.com
Room Air Conditioner
SVC MANUAL(Exploded View)
MODEL : R1003A3
R-8000AY3
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Related Manuals for LG R1003A3
Air Conditioner LG R-8000A Service Manual
Room air conditioner (29 pages)
Air Conditioner LG R120AH Owner's Manual
Single package type air conditioner (22 pages)
Air Conditioner LG R1402 Service Manual
(30 pages)
Air Conditioner LG I09AWN-NB11 Owner's Manual
Wall mounted, indoor/outdoor unit (23 pages)
Air Conditioner LG M09AWN-NB11 Owner's Manual
Wall mounted air conditioner (23 pages)
Air Conditioner LG R18AWN-NC11 Owner's Manual
(23 pages)
Air Conditioner LG M18AWN-NC11 Owner's Manual
Wall mounted, indoor/outdoor unit (23 pages)
Air Conditioner LG R18AWN-NC9 Installation Manual
(28 pages)
Air Conditioner LG WR-8030 Service Manual
(32 pages)
Air Conditioner LG WR-8030 Service Manual
Room air conditioner (35 pages)
Air Conditioner LG M2400HR Service Manual
Room air conditioner (36 pages)
Air Conditioner LG M1804RY3 Svc Manual
Room air conditioner (37 pages)
Air Conditioner LG AS-W186C2U1 Svc Manual
Room air conditioner (12 pages)
Air Conditioner LG R12AWN-NB9 Owner's Manual
Wall mounted (27 pages)
Air Conditioner LG R18AQN-NC10 Owner's Manual
Wall mounted (23 pages)
Air Conditioner LG R09AQN-NB10 Owner's Manual
(23 pages)
Summary of Contents for LG R1003A3
Page 1
Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : R1003A3 R-8000AY3 CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.
Page 2: Table Of Contents
4. The value should be over 1MΩ. tance test to protect the customer from being exposed to shock hazards. - 2 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 3: Specifications
OUTSIDE DIMENSION (inch) 470 x 353 x 525 (W x H x D) (mm) * DB:Dry Bulb ** WB:Wet Bulb - 3 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 4: Features
MED COOL : Permits cooling with the medium fan speed operation. LOW COOL : Permits cooling with the low fan speed operation. - 4 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 5: Disassembly Instructions
(Refer to the circuit diagram found on page 24, in this manual or on the control box.) Figure 3 - 5 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 6: Air Handling Parts
7. Remove the fan and then pull out the shroud. (See Figure 6) 8. Re-install the components by referring to the removal procedure. Figure 6 - 6 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 7: Electrical Parts
6. Disconnect all the leads of capacitor terminals. 7. Re-install the components by referring to the removal procedure, above. (See Figure 9) Figure 9 - 7 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 8: Power Cord
8. Remove the motor. 9. Re-install the components by referring to the removal procedure, above.(See Figure 13) Figure 13 - 8 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 9: Refrigeration Cycle
3. Remove the capillary tube. 4. Re-install the components by referring to the removal procedure. - 9 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 10
Open valve C. Discharge the line at the manifold connection. 5) The system is now ready for final charging. - 10 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 11
Leak detector, Tubing cutter, Hand Tools to remove components, Service valve. Figure 16B-Charging Figure 16A-Pulling Vacuum - 11 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 12: Installation
If the air conditioner is used in a hot and high Figure 19 humidity zone, exchange the HOLE RUBBER for the DRAIN PIPE.(See figure 18, figure 19.) - 12 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 13: How To Install
SCREW(TYPE B) SCREW(TYPE C) FOAM-STRIP UPPER GUIDE FOAM-PE FRAME GUIDE WINDOW LOCKING BRACKET FOAM-PE DRAIN JOINT PIPE DRAIN WASHER - 13 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 14
• Do not pull the window sash down so tightly that the Foam-pe movement of Frame Curtain is restricted. Cabinet Frame Curtain Foam-pe Figure 21 - 14 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 15
CAUTION: DO NOT DRILL A HOLE IN THE BOTTOM PAN. The unit is designed to operate with approximately 1/2" of water in bottom pan. Figure 25 - 15 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 16
15. Window installation of room air conditioner is now completed. See ELECTRICAL DATA for attaching power cord to electrical outlet. Figure 31 - 16 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 17: How To Use The Reversible Inlet Grille
4. If you want to pull out the filter downward, use the reversible inlet grille without change. (The grille is already assembled for that way.) Figure 35 - 17 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 18: Outside Dimensions
LIQUID LIQUID OUTLET PRESSURE DROP (LIQUID REFRIGERANT) HIGH PRESSURE VAPOR LIQUID REFRIGERANT CAPILLARY TUBE LOW PRESSURE VAPOR Figure 36 - 18 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 19: Troubleshooting Guide
Satisfactory operation with compressor. Repair clogging in refrigera- temperature difference of tion circuit. inlet & outlet air ; 44~50°F(7~10°C) - 19 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 20
Regular but fails to start. Irregular motor insulation ( Replacement of compressor (locking of piston, metal). Replacement of compressor (Motor damaged) - 20 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 21
Pay attention to any change from high speed to low speed. If the speed does not change, replace the motor. - 21 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 22
Check overload, if externally mounted. Replace if open. (If the compressor temperature is high, remove the overload, cool, and retest.) - 22 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 23
Copper tubing Remove the cabinet carefully, rearrange the tubing not to contact cabinet, compressor, shroud, and barrier. - 23 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 24: Schematic Diagram
REF. NO. DESCRIPTION & NAME Q'TY PER SET POWER CORD ROTARY SWITCH FAN MOTOR CAPACITOR THERMOSTAT OVERLOAD PROTECTOR COMPRESSOR - 24 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 25: Exploded View
554160 550140 147582 135312 147581 W52106A W52106B 249950 266003 552111 269310 W0CZZ 552113 137215 352113 135500 149410 35211A 264110 - 25 - Copyright ©2007 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
Page 26
FEBRUARY, 2008 P/NO : 3828A20294G...
This manual is also suitable for:
R-8000ay3
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL