2-3. Simple Aging
[ Content of Test ]
Performs random playback of disc randomly. Implement the following process 400 cycles.
• Tray close → • 50 times of short playback on voluntary points → • Tray open
1cycle BD : 75 seconds x 400 times
DVD
CD
[ Instructions ]
B
1 Select "[7] Enter SP Mode" with the  button from the Service Mode screen, and press the [ENTER] button.
2 The SP Mode window menu will be displayed, so select "Simple Aging" and press the [ENTER] button.
3 The tray will automatically open and the dedicated screen will appear. Place the disc you wish to use on the tray, and
push it in manually. ([Close] button will not function)
4 The tray will reopen automatically. Aging will start when you push the tray in manually.
5 After aging is successfully finished, the screen shown below will be displayed.
(The message "OK C3" will be displayed on the FL display.)
C
Note1: DVD and BD disc can be checked with Single Layer (SL) disc only.
If they are checked with Dual Layer (DL) disc, an Error is generated.
• Error List
D
The following serves as the Error List generated in SP MODE.
Error Code
12
PWR_CURVE_ERROR
22
STARTUP_TIMEOUT_ERROR
23
MEDIA_MISMATCH
25
DISCID_ERROR 0x25
26
MEDIUM_SUPPORT_ERROR
31
TRAYOUT_ERROR
32
TRAYIN_ERROR
E
33
FLASH_UPDATE_ERROR
36
OPU_TEMP_ERROR
41
SEEK_TIMEOUT_ERROR
42
SEEK_CMD_FAIL_ERROR
51
READ_TOC_ERROR
52
TOC_TIMEOUT_ERROR
61
PIPO_TIMEOUT_ERROR
62
PIPO_C1C2_ERROR
63
PIPO_C1C2_OVER
71
RD_CMD_FAIL_ERROR
F
72
RD_CMD_ERROR
73
RD_TIME_OUT_ERROR
81
CHECK_FA_TABLE_ERROR
8
1
2
: Approx. 90 seconds x 400 times = Completed in a total of approx. 10 hours
: Approx. 95 seconds x 400 times = Completed in a total of approx. 10 hours 40 minutes
0x4E20 = 20000
(Fifty times of random playback multiplied by 400 cycles equals 20,000.)
Error Name
Power curve chk-sum error
Time-out criterion over
Wrong disc
Disc ID error
Unsupported disc
Tray-out time-out criterion over
Tray-in time-out criterion over
Updating FA result failed
Abnormal OPU temperature
Seek time-out criterion over
Seek command failed
Read TOC command failed
TOC read time-out criterion over
Time-out criterion over
Read PIPO command failed
PIPO criterion over
Read command failed
Command error or illegality mode
Read command time-out criterion over
FA table check-sum error
2
3
= Completed in a total of approx. 8 hours 20 minutes