hit counter script

Advertisement

Quick Links

MANUAL DE INSTRUÇÕES DO
MULTÍMETRO DIGITAL
MODELO MD-6
Manual em inglês
Leia atentamente as instruções
contidas neste manual antes de
iniciar o uso do instrumento

Advertisement

Table of Contents
loading

Summary of Contents for ICEL MD-6000

  • Page 1 MANUAL DE INSTRUÇÕES DO MULTÍMETRO DIGITAL MODELO MD-6 Manual em inglês Leia atentamente as instruções contidas neste manual antes de iniciar o uso do instrumento...
  • Page 2: Table Of Contents

    Table of Contents 1.Safety Information ....................1 Safety Considerations ....................... 1 Measurement Category ......................3 Safety Terms and Symbols ......................4 2.General Characteristics ..................... 5 3.Quick Start ........................ 6 General Inspection ........................6 Install the Batteries ........................6 Adjusting the Tilt Stand ......................7 Power On..........................
  • Page 3 Capturing Max. and Min. Values .................... 17 Making Relative Measurements ..................... 17 Buzzer Feature ........................18 6.Bluetooth Function ................19 How to Connect ........................19 User Interface ......................... 21 Operations ..........................22 7.Technical Specifications ..................24 8.Appendix ......................... 26 Appendix A: Enclosure ......................
  • Page 4: Safety Considerations

    1.Safety Information 1. Safety Information Safety Considerations Before any operations, please read the following safety precautions to avoid any possible bodily injury and prevent damage to this product or any other products connected. To avoid any contingent danger, use this product only as specified. Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Page 5: Safety Information

    1.Safety Information When using the test leads, keep your fingers behind the finger guards on the test  leads. Remove the test leads from the multimeter before you open the battery cover.  To avoid false readings, which may lead to possible electric shock or personal injury, ...
  • Page 6: Measurement Category

    1.Safety Information Measurement Category The multimeter has a safety rating of 1000 V, CAT III. Measurement category definition Measurement CAT I applies to measurements performed on circuits not directly connected to the AC mains. Examples are measurements on circuits not derived from the AC mains and specially protected (internal) mains- derived circuits.
  • Page 7: Safety Terms And Symbols

    1.Safety Information Safety Terms and Symbols Safety Terms Terms in this Manual. The following terms may appear in this manual: Warning: Warning indicates the conditions or practices that could result in personal injury or death. Caution: Caution indicates the conditions or practices that could result in damage to this product or other property.
  • Page 8 MD - 6 0 0 0...
  • Page 9: General Characteristics

    2.General Characteristics 2. General Characteristics Features and benefits:  Data transferring via Bluetooth, interacting with mobile device to read measurements, analyze via special chart mode, remote control, voice-out feature; voice warning supported, which enhances measurement safety ; digit reading, achieving higher measurement accuracy than digit ...
  • Page 10: Quick Start

    Manual. You can check whether there is any loss of accessories with reference to this description. If it is found that there is any accessory lost or damaged, please get in touch with the distributor of ICEL responsible for this service or the ICEL's local offices.
  • Page 11: Adjusting The Tilt Stand

    3.Quick Start (2) Lift the tilt stand and loosen the screws with a suitable Phillips screwdriver and remove the battery cover. (3) Observe the battery polarity indicated inside the battery compartment, Insert the batteries. (4) Place the battery cover back in its original position and tighten the screws. Caution: To avoid instruments being damage from battery leakage, always remove the batteries and store them separately if the multimeter is not going to be used for a long period.
  • Page 12: Selecting The Range

    3.Quick Start Selecting the Range  Auto ranging is set as default when the meter is powered on, is displayed.  When auto ranging is enabled, press to enter the manual range mode.  In manual range, each additional press of sets the multimeter to the next higher range, unless it is already in the highest range, at which point the range switches to the lowest range.
  • Page 13: Rotary Switch

    3.Quick Start Description Details ① Display screen Page 10 ② Keypad Page 9 ③ Rotary switch Page 9 ④ Input terminals Page 12 Rotary switch Position Description Details Power off Page 7 DC or AC voltage measurement Page 13 DC or AC voltage measurement (up to 600 millivolts) Continuity test Page 14...
  • Page 14: Display Screen

    3.Quick Start Page 15 Select frequency/duty cycle Page 17 Capturing Max. and Min. Values Page 7 Backlight Data Hold Page 17 Page 17 Relative Measurements Bluetooth Page 19 Display screen Figure 3-2 Display screen Symbol Description Details Bluetooth enabled Page 19 Auto range Page 8 Maximum reading...
  • Page 15 3.Quick Start Continuity test selected Page 14 Battery is low Page 6 Page 13 and Page 16 Measurement display ("OL" is short for overload, indicates the reading exceeds the display range) Measuring units Page 11 Analog bar graph Measurement units Sign Description Mega...
  • Page 16: Input Terminals

    3.Quick Start Input terminals The terminal connections for the different measurement functions of the multimeter are described in the table below. Warning: Before starting any measurement, observe the rotary switch position of the multimeter, and then connect the test leads to the correct terminals.
  • Page 17: Making Measurements

    4.Making Measurements 4. Making Measurements Measuring AC or DC Voltage Warning: Do not measure any voltage of over 1000 Vdc or 750 Vac rms to avoid instrument damage or electric shock. Do not apply more than 1000 Vdc or 750 Vac rms between the common terminal and the earth ground to avoid instrument damage or electric shock.
  • Page 18: Testing Diodes

    4.Making Measurements Testing Diodes Caution: To avoid possible damage to your multimeter or to the equipment under test, disconnect the circuit power and discharge all high-voltage capacitors before testing diodes. (1) Rotate the rotary switch to . Press once to enter diode testing mode, will be displayed.
  • Page 19: Measuring Frequency

    4.Making Measurements Note: For the 4000 uF range, the measuring duration should be over 30 seconds. (1) Rotate the rotary switch to . Press three times to enter capacitance measuring mode, the Farad units will be displayed. (2) Connect the black test lead to the terminal and the red test lead to the terminal.
  • Page 20: Measuring Dc Or Ac Current

    4.Making Measurements (2) Connect the red connection of the K-type thermocouple to the terminal and the black connection to the terminal. (3) Probe the test points and read the display. Press to change the temperature units between Measuring DC or AC Current Warning: Never attempt an in-circuit current measurement where the open-circuit potential to earth is greater than 250 V.
  • Page 21: Multimeter Features

    5.Multimeter Features 5. Multimeter Features Data Hold Mode (1) Press to freeze the display during measurement, will be shown on the display. (2) Press again to exit this mode. Note: This function is not available when measuring diodes and transistor. Capturing Max.
  • Page 22: Buzzer Feature

    3.Quick Start Selecting the Range  Auto ranging is set as default when the meter is powered on, is displayed.  When auto ranging is enabled, press to enter the manual range mode.  In manual range, each additional press of sets the multimeter to the next higher range, unless it is already in the highest range, at which point the range switches to the lowest range.
  • Page 23: Bluetooth Function

    6.Bluetooth Function 6. Bluetooth Function MD-6000 multimeter supports communications with Android based smart device through Bluetooth. You can use the free application software on the Android based smart devices to monitor the measurements, perform remote control, view trending graphs, etc. The recorded data can be saved as.CSV file.
  • Page 24 6.Bluetooth Function (3) Launch the application (4) Click the icon on the top left of the screen to launch device connection. (5) If the Bluetooth function is activated, skip this step; if not, a dialog box will ask whether to turn on Bluetooth. Click "Yes". Click to scan for Bluetooth devices.
  • Page 25: User Interface

    6.Bluetooth Function User Interface Double View Double View Click to disconnect Press&hold to edit name Click to enter Single View Next Single Graph Exit/About page view &Table Single View Single View Voice out Click to disconnect Press&hold to edit Range Function (Details follow) Same keys of...
  • Page 26: Operations

    6.Bluetooth Function Function Description Table Display Function Display Function Direct Current Measuring Capacitance Alternating Current Measuring Frequency Measuring Resistance Measuring Duty Cycle Testing Diodes Measuring Transistor Testing for Continuity Measuring Temperature BEEP TEMP Operations  Customize the meter name The device name of meter can be customized. Press and hold the name on the top left of the scree, a dialog box below will pop up.
  • Page 27 6.Bluetooth Function Upgrade Online : Click , and click "About", the following interface is shown. Click  "Upgrade" as below. Click to upgrade  Data Graph and Table : Click to view data graph and table. Click show setting menu. Data Graph&Table Data Graph&Table Trending...
  • Page 28: Technical Specifications

    7.Technical Specifications 7. Technical Specifications All these specifications apply to the multimeter unless otherwise explanation. Note: "T" in the model indicates true RMS (optional). Standard conditions: The environment temperature is 18℃ to 28℃, the relative humidity is less than 80%. Resolu- Function Measurement Range...
  • Page 29: Continuity Test

    7.Technical Specifications be over 30 seconds. When measuring frequency, the typical waveform is Square or Sine. The signal meets the following conditions. Frequency Amplitude (rms) 1 Hz – 4 MHz ≥ 100 mV 4 M – 8 M ≥ 200 mV 8 M –...
  • Page 30: Appendix

    8.Appendix 8. Appendix Appendix A: Enclosure Standard Accessories: Test lead Multi-functional K-type User Manual test socket thermocouple Options: Alligator clip Thin-tipped test lead Appendix B: General Care and Cleaning Warning: To avoid electrical shock or damage to the multimeter, ensure that the insides of the casing stay dry at all times.
  • Page 31: Appendix C: Fuse Replacement

    8.Appendix Appendix C: Fuse Replacement Use the following procedure to replace the fuse. 1. Ensure that the rotary switch is at the position. Remove test leads and any connectors from the input terminals. 2. Lift the tilt stand and loosen the screws with a suitable Phillips screwdriver and remove the battery cover.
  • Page 32 icel@icel-manaus.com.br...

Table of Contents