hit counter script
ABB VICPAS CP660-x Operating Instructions Manual

ABB VICPAS CP660-x Operating Instructions Manual

Hide thumbs Also See for VICPAS CP660-x:

Advertisement

Quick Links

Operating Instructions
Control Panels CP600
CP650-x, CP650-WEB-x
CP660-x, CP660-WEB-x
CP675-x, CP675-WEB-x

Advertisement

Table of Contents
loading

Summary of Contents for ABB VICPAS CP660-x

  • Page 1 Operating Instructions Control Panels CP600 CP650-x, CP650-WEB-x CP660-x, CP660-WEB-x CP675-x, CP675-WEB-x...
  • Page 2: Table Of Contents

    Content Introduction ........................3 Before You Start ........................ 4 Safety Notices........................... 4 Markups ............................ 4 Product Overview ......................5 Standards and Approvals ....................6 Product Identification ....................... 6 Technical Specifications ......................7 Environmental Conditions ....................... 7 Electromagnetic Compatibility (EMC) ..................8 Durability Information ......................
  • Page 3 System Settings ....................... 23 Dedicated LED Indicators ....................25 Unpacking and Packing Instructions ................26 Operating Instructions CP650, CP660, CP675...
  • Page 4: Introduction

    Introduction The operational guidelines described below is information which relates to the device, place of employ- ment, transportation, storage, assembly, use and maintenance. The products have been designed for use in an industrial environment in compliance with the 2004/108/CE directive. The products have been designed in compliance with: ...
  • Page 5: Before You Start

    Before You Start Safety Notices Indicates an imminent risk. It will lead to death or serious injury if not avoided. DANGER! Indicates a possible risk. It may lead to death or serious injury if not avoided. WARNING! Indicates a possible risk. It may lead to light or slight injury or material damage if not avoid- CAUTION! Markups ...
  • Page 6: Product Overview

    Product Overview The Control Panels combine state-of-the-art features and top performance with an oustanding design. They are the ideal choice for all demanding HMI applications including factory and building automation. These Control Panels have been designed to run the PB610 Panel Builder 600 software. ...
  • Page 7: Standards And Approvals

    Standards and Approvals The Control Panels have been designed for installation and use in an industrial environment in compli- ance with the 2004/108/EC EMC Directive and with the following harmonized standards:  EN 61000-6-4  EN 61000-6-2 In compliance with the above regulations the products are CE marked. The installation of these devices into the residential, commercial and light-industrial environments is al- lowed only in the case that special measures are taken in order to get the conformity to EN 61000-6-3.
  • Page 8: Technical Specifications

    Technical Specifications Parameter Value Back-up battery 3V 50mAh Lithium, rechargeable, not user-replaceable, PANASONIC model VL2330 Fuse Automatic Environmental Conditions Parameter Value According to 0 °C … +50 °C Operating temperature (vertical installation) EN 60068-2-14 -20 °C … +70 °C Storage temperature EN 60068-2-14 5 % …...
  • Page 9: Electromagnetic Compatibility (Emc)

    Electromagnetic Compatibility (EMC) Test executed on the 230 V AC side of the Power Supply (EN 61000-4-11). Parameter Value According to Emitted interference Class A EN 55011 Electrostatic 8 kV (air electrostatic discharge) EN 61000-4-2 4 kV (contact electrostatic discharge) 80 MHz …...
  • Page 10: Durability Information

    Durability Information Parameter Value Backlight service life (LED type) MTBF value: 40,000 hrs (time of continuos operation until the brightness of the backlight reaches 50 % when the sorrounding temperature reach 25 °C), see Backlight service life (CCFL type) MTBF value: 50,000 hrs or more (time of continuos operation until the brightness of the backlight reaches 50 % when the sorrounding temperature is 25 °C), see Battery lifetime...
  • Page 11: Technical Data

    Technical Data Model CP650(-WEB)-x CP660(-WEB)-x CP675(-WEB)-x Display/Backlight TFT Color / LED TFT Color / CCFL TFT Color / CCFL Colors 64 K 64 K 64 K Resolution 800 x 600 800 x 600 1024 x 768 10.4” 12.1“ 15“ Diagonal (inches) Dimming Touchscreen User memory flash...
  • Page 12: Dimensions

    Dimensions Model inches inches inches inches inches 10.86” 8.70” 1.65” 9.13” 11.30” CP650(-WEB)-x 9.30” 10.1” 1.65” 10.51” 13.26” CP660(-WEB)-x 15” 11.65” 1.82” 12.1” 15.43” CP675(-WEB)-x Model CSD: Minimum compass safe distance CSD2: Minimum compass safe distance of standard compass of steering compass, standby steering compass and emergency compass inches inches...
  • Page 13: Installation Environment

    Installation Environment The equipment is not intended for continuous exposure to direct sunlight. This might accelerate the aging process of the front panel film. The equipment is not intended for installation in contact with corrosive chemical compounds. Check the resistance of the front panel film to a specific compound before installation. Do not use tools of any kind (screwdrivers etc.) to operate the keyboard of the panel or the touchscreen.
  • Page 14: Installation Procedure

    Installation Procedure  Place the fixing brackets. Screw each fixing screw until the bezel corner gets in contact with the panel. CAUTION! Operating Instructions CP650, CP660, CP675...
  • Page 15: Connections

    Connections Connections of the Control Panel PLC port – COM1 Power Ethernet port PC/printer port – COM2 Aux port USB port for Serial Ports The serial ports COM1 and COM2 can be used to communicate with the PLC or with another type of con- troller.
  • Page 16 Communication Cable The communication cable must be chosen for the type of device being connected. Connection to an AC-500 with the TK681 CP600-AC500 RS232 communication cable Connection to an AC-500(-eCo) with the TK682 CP600-AC500-eCo RS485 communication cable Shield SubD9 male Operating Instructions CP650, CP660, CP675...
  • Page 17: Ethernet Port

    Ethernet Port Ethernet Port OFF: No activity ON: Valid link hast NOT been detected BLINKING: Activity OFF: Valid link has been detected Description Description Description Description TX OUT + RX OUT + TX OUT - RX OUT - Operating Instructions CP650, CP660, CP675...
  • Page 18: Power Supply, Grounding And Shielding

    Power Supply, Grounding and Shielding DC Power Connector, Female - R/C Terminal Blocks (XCFR2), manufactured by Weidmüller Inc., Cat. No. BLZ 5.08, torque 4.5 lb-in Ensure that the power supply has enough power capacity for the operation of the equipment. NOTE The unit must always be grounded to earth.
  • Page 19 All the electronic devices in the control system must be properly grounded. Grounding must be performed according to applicable regulations. Operating Instructions CP650, CP660, CP675...
  • Page 20: Aux Port

    AUX Port The AUX port is a communication port specially designed for industrial network communication. The AUX port connector is a 9 pin D sub type. The functionality of the AUX port depends on the optional Communi- cation Module which is plugged into the unit. The pin assignment of the AUX port connector is described in the manual of the Communi- cation Module.
  • Page 21: Battery

    Battery The Control Panels are equipped with a rechargeable lithium battery, not user-replaceable. The battery maintains the hardware real-time clock (date and time). Charging the Battery  At first installation recharge the battery for 48 hours.   When the battery is charged, it assures a period of 3 month of data back-up at 25 °C.
  • Page 22: Cleaning Faceplates

    Cleaning Faceplates The equipment must be cleaned only with a soft cloth and neutral soap product. Do not use solvents. Operating Instructions CP650, CP660, CP675...
  • Page 23: Getting Started

    Getting Started The Control Panels must be programmed with the programming package PB610 Panel Builder 600. The Control Panels are programmed via the Ethernet interface.  The Control Panel must be in configuration mode to be programmed.  To program a Control Panel connect the Control Panel to a PC running PB610 Panel Builder 600 software package.
  • Page 24 System Settings The Control Panels have a system settings tool to allow basic and preliminary settings to the unit. System settings tool The system settings tool is a rotating menu.  Use the navigation buttons Next and Back to scroll between the available options. ...
  • Page 25 System Mode  System Mode is the complete interface of the system settings tool where all options are available. Additionally to the options of the User Mode the following options are available:  Format Flash: allows to format the internal panel flash disk ...
  • Page 26 Dedicated LED Indicators There is one LED in the upper left part of the front below the red stripe. The meaning of the LED indicator is explained in the following table: LED color Status Meaning Normal operation Green Communication error or alarm requires acknowledgement Blinking Hardware fault Battery low...
  • Page 27 Unpacking and Packing Instructions  To repack the unit follow the instructions backwards. Operating Instructions CP650, CP660, CP675...
  • Page 28 68526 Ladenburg, Germany notice. With regard to purchase orders, the agreed Phone: +49 62 21 701 1444 particulars shall prevail. ABB AG does not accept any Fax: +49 62 21 701 1382 responsibility whatsoever for potential errors or possible lack of information in this document.

Table of Contents