Page 1
Operation Manual TPL65VA33 ABB Turbo Systems Ltd CH 5401 Baden Type TPL65VA33 HT565892 Mmax Mmax °C Bmax Bmax 01210 Application according to Year 2016 the Operation Manual made in Switzerland ABB Turbocharging...
Page 2
In case the operation conditions differs signifi cantly from what is considered to be normal for the cur- rent application, it is recommended to contact ABB for a re-calculation of replacement intervals. Frequent load alterations, high temperatures and high speed lower the life of components.
Operation Manual This Operation Manual enables you to familiarize yourself with the turbocharger supplied by ABB Turbo Systems and to use it as intended. It provides important information in order that the turbocharger can be operated safely, correctly and efficiently.
Any other use will be regarded as a special application which must first be discussed with ABB Turbo Systems. The manufacturer accepts no liability for other applications. If it is used otherwise, ABB Turbo Systems reserves the right to reject all warranty claims.
Storage of new turbochargers and spare parts Storage of new turbochargers and spare parts up to 6 months New turbochargers and spare parts from ABB Turbo Systems can be stored in sealed packaging without additional mothballing measures for up to 6 months from the date of delivery (marked by the VCI label on the package).
Page 13
Page 11 spare parts Long-term storage of replacement turbochargers or spare parts Per order, turbochargers or cartridge groups will be prepared by ABB Turbo Systems for prolonged storage. The package is equipped with a hygrometer (see illustration). The following measures are required every 6 months: Check the hygrometer (02) in the sight-glass.
Page 15
Only use original parts from ABB Turbo Systems. ABB Turbo Systems accepts no liability for any damage resulting from the use of non-original parts and corresponding accessories. Competence of personnel The turbocharger must only be operated and serviced by trained and authorised personnel.
Page 16
This document is valid for different design variants of turbochargers. There may be sections and descriptions of components that are not relevant for a specific turbocharger variant. ABB Turbocharging Service Stations will be happy to provide information on questions regarding a design variant (see Contact information at www.abb.com/turbocharging).
Definition of caution / warning The caution and warning signs are described in the chapter Safety. ABB Turbo Systems In this document, ABB Turbo Systems Ltd is abbreviated to ABB Turbo Systems. Official ABB Turbo Systems Service Stations In this document, official service stations are referred to as ABB Turbocharging Service Stations.
Page 19
A rating plate is attached to the turbocharger foot, one on the left and one on the right. In the case of turbochargers with insulation supplied by ABB Turbo Systems, at least one additional rating plate is attached to the insulation of the gas outlet casing.
Operation Manual / TPL65VA32/33 Preliminary remarks Contact information Page 18 Contact information Contact information Contact information for the official service stations of ABB Turbo Systems is available online. Scan the QR code to access our website. ABB Turbo Systems AG Bruggerstrasse 71a...
Page 19 Safety Introduction Turbochargers manufactured by ABB Turbo Systems are state of the art and comply with the pertinent safety and health-protection requirements that applied when the turbocharger was manufactured. Consequently, the turbocharger is safe to operate. Nevertheless, during turbocharger...
Warning plates on the turbocharger Page 23 Warning plates on the turbocharger Warnings that have been attached to turbochargers by ABB Turbo Systems must not be removed. Illegible warnings must be replaced with new ones. Further information is available from ABB Turbocharging service stations.
Page 31
Hot surfaces on uninsulated turbochargers Uninsulated turbochargers can cause serious personal injuries (burns). The turbocharger is supplied by ABB Turbo Systems without insulation WARNING depending on the order from the engine builder. In this case, the engine builder is responsible for insulating the turbocharger properly or for providing protection against hot surfaces being touched.
Page 33 vessel Periodic checking of the pressure vessel The pressure vessels used by ABB Turbo Systems, such as those for wet or dry cleaning, are so-called "simple pressure vessels". The local, statutory regulations covering periodic checks of pressure vessels must be observed.
Page 41
The first step is NOTICE to check the seal for the oil supply to the turbocharger. If this is not in proper condition, contact an official ABB Turbocharging service station. 3.2.4 Inspection after 100 service hours Clean or replace lubricating oil filters after the first 100 service hours.
Systems. Service inspection after 5 years To prevent age- and stoppage-related machine damage, an inspection by an ABB Turbocharging Service Station is recommended at the latest NOTICE 5 years after the last service. 4.2.1 Service work every 25 … 50 hours Visual inspection for air, exhaust gas, water and oil leaks.
Page 47
(Customer Part Exchange) programme. 4.2.5 Service work every 30000 hours The replacement of bearing parts as well as the inspection and assessment of the rotor must be carried out by an ABB Turbocharging Service Station. Disassemble turbocharger. Measure clearances.
Page 49
50000 … 100000 Variable turbine geometry module 15000 (The variable turbine geometry module can be replaced with a CPEX variable turbine geometry module by an ABB Turbocharging service station.) Turbine diffuser / cover ring 35000 … 50000 Other casings 100000 Axial bearing components 24000 …...
Page 63
Cleaning of the compressor during operation is carried out using the cleaning method described in the following: Wet cleaning This cleaning method has been tested and approved by ABB Turbo Systems. To clean the compressor stage during operation, water is injected in front...
Page 64
Operating state prerequisites for cleaning compressor with XC2 To be able to carry out a satisfactory cleaning process which has been tested and is recommended by ABB Turbo Systems, the following prerequisites must be fulfilled: Engine load 50 ... 85% ...
Page 65
Operating state prerequisites for compressor cleaning with XC3 To be able to carry out a satisfactory cleaning process which has been tested and is recommended by ABB Turbo Systems, the following prerequisites must be fulfilled: Engine load 50 ... 85% ...
Page 66
If the cleaning results are still not satisfactory after three attempts and the engine values are also unsatisfactory, we recommend that you have NOTICE the turbocharger inspected and cleaned by an official ABB Turbocharging Service Station. Cleaning parameters per turbocharger compressor...
Certain tolerances must be observed to avoid a significant loss of efficiency. If there is any doubt about the extent of rubbing, then an ABB Turbocharging Service Station must be contacted. Have a dimension check carried out by an ABB Turbocharging Service Station.
Prolonged or periodic surging Possible damage to components, such as the compressor wheel, turbine blades, bearings and filter silencer CAUTION Have the cause clarified immediately by an ABB Turbocharging service station and rectified. Have components inspected for damage and, if necessary, replaced ...
This problem is eliminated by removing the gasket. Defective sensor Contact ABB Turbocharging service station. Measured Dirty sensor tip The sensor tip is magnetic and can thus speeds too attract metal particles.
CAUTION Only carry out those tasks that are described in this chapter. Marking casing positions for assembly ABB Turbo Systems recommends that the casing positions are marked before disassembling the turbocharger. NOTICE Identifying assembly devices Not all assembly devices are marked with a part number. They can be identified using the tool list.
Carefully separate gas inlet casing (51001) from variable turbine geometry module (56100) and remove it. Have the variable turbine geometry module overhauled by ABB Turbo Systems. ABB Turbocharging Service Stations have variable turbine geometry modules replaced with overhauled ones as part of the CPEX (Customer Part Exchange) programme.
Page 99
Clearances out of tolerance and excessively worn components can be the cause of serious damage to machinery and property. CAUTION Have components assessed and, if necessary, replaced by an ABB Turbocharging Service Station. Connect oil pipes and all air lines in accordance with engine builder’s ...
Page 112
If the total acid number (TAN) is greater than 2 mg KOH/g, the following mothballing measures are necessary after taking an engine out of operation: Dismantle the turbocharger. The rotor and the bearing parts must be removed by an official ABB Turbocharging service station and refitted afterwards. Clean all parts. ...
Page 113
The turbocharger remains mounted on the engine. The turbocharger casing remains mounted on the engine, but the rotor and the bearing parts are removed and stored separately by an ABB Turbocharging Service Station. The turbocharger is removed completely, either as a whole or in individual parts.
Page 117
Turbocharger type Serial number (HT……) Description and part number Spare parts can be ordered from an official ABB Turbocharging Service Station. If different design versions have not been taken into consideration in this document, please contact an ABB Turbocharging Service Station.