Operation Manual / A130-H.. - A140-H..
9 Dismantling and fitting / 9.15 Installing the compressor casing
Installing the compressor casing
Fig. 54: Installing the compressor casing
*) In some installations a special graphite cord sealing (42126) is fitted instead of the O-
ring (42012) (see also chapter
Product
A130
A135
A140
Table 41: Tightening torque (72011)
1. Fit a new, high temperature-resisting O-ring (42012, red or green) (see chapter
customer spare part set (97070)
2. Thoroughly clean the fastening strips (72012) before assembly.
3. Attach swivel lifting eyes (01) to the compressor casing (72000) and lifting gear.
4. Install the compressor casing (72000).
5. Install the fastening strips (72012) with screws (72011).
© Copyright 2021 ABB. All rights reserved.
Spare parts
→110).
Size
M8
M10
M12
→110).
HZTL4030_EN
Tightening torque [Nm]
35
70
105
Required
Rev.G
July 2021