Toshiba RAS-B18G3KVSG-E Installation Manual
Hide thumbs Also See for RAS-B18G3KVSG-E:

Advertisement

INSTALLATION MANUAL
AIR CONDITIONER (SPLIT TYPE)
Indoor unit
RAS-B18, 22, 24G3KVSG-E
RAS-B18, 22, 24G3KVSGB-E
Outdoor unit
RAS-18J2AVSG-E1
RAS-22J2AVSG-E1
RAS-24J2AVSG-E1
ENGLISH
1144350101

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAS-B18G3KVSG-E

  • Page 1 INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-B18, 22, 24G3KVSG-E RAS-B18, 22, 24G3KVSGB-E Outdoor unit RAS-18J2AVSG-E1 RAS-22J2AVSG-E1 RAS-24J2AVSG-E1 1144350101...
  • Page 2: Table Of Contents

    CONTENTS PRECAUTIONS FOR SAFETY ............................1 ACCESSORY PARTS .................................5 INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS ...................6 Optional Installation Parts ...............................6 INDOOR UNIT ..................................7 Installation Place ................................7 Cutting a Hole and Mounting Installation Plate .......................7 Piping and Drain Hose Installation ..........................8 Indoor Unit Fixing ................................8 Drainage ..................................9 OUTDOOR UNIT .................................9...
  • Page 3: Precautions For Safety

    PRECAUTIONS FOR SAFETY Read the precautions in this manual carefully before This appliance is fi lled with R32. operating the unit. Warning indications on the air conditioner unit CAUTION CAUTION BURST HAZARD BURST HAZARD Open the service valves Open the service valves before the operation, before the operation, otherwise there might be the burst.
  • Page 4 DANGER FOR USE BY QUALIFIED PERSONS ONLY. TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK. MAKE SURE ALL POWER SWITCHES ARE OFF. FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK. CONNECT THE CONNECTING CABLE CORRECTLY. IF THE CONNECTING CABLE IS CONNECTED WRONGLY, ELECTRIC PARTS MAY BE DAMAGED.
  • Page 5 WARNING After installation work, make sure below before operation. Connection pipes are connected properly and no leakage. Packed valves are fully open. During pump down work make sure below process. Don’t mix air into the refrigerant cycle. Stop the compressor before removing piping after packed valves are fully closed.
  • Page 6 CAUTION • Exposure of unit to water or other moisture before installation could result in electric shock. Do not store it in a wet basement or expose to rain or water. • After unpacking the unit, examine it carefully for possible damage. •...
  • Page 7: Accessory Parts

    Installation plate × 1 Wireless remote control × 1 Battery × 2 Remote control holder × 1 Toshiba Ultra pure fi lter × 2 Mounting screw × 6 Flat head wood screw × 2 Owner’s Manual × 1 Installation Manual × 1 Screw ×...
  • Page 8: Installation Diagram Of Indoor And Outdoor Units

    INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS For the rear left, bottom left and left piping Wall Hook Installation plate Cut out a piece of SPACER from indoor unit packaging box, roll it and insert between the indoor unit and wall to tilt the indoor unit for better operation.
  • Page 9: Indoor Unit

    INDOOR UNIT Space allows for of the air inlet tal louver in Installation Place operation above curtain rails, window cornice or other objects. (Unit : mm) A place which provides the spaces around the indoor unit as shown in the A place where there are no obstacles near the air inlet and outlet A place which allows easy installation of the to the outdoor unit...
  • Page 10: Piping And Drain Hose Installation

    Left-hand connection with piping Piping and Drain Hose Installation Bend the connecting pipe so that it is laid within 43 mm above the wall Piping and drain hose forming surface. If the connecting pipe is laid exceeding 43 mm above the wall surface, the indoor unit may unstably be set on the wall.
  • Page 11: Drainage

    2. Put water in the drain pan and make sure that the water is drained out of Drainage doors. 3. When connecting extension drain hose, insulate the connecting part of extension drain hose with shield pipe. 1. Run the drain hose sloped downwards. Shield pipe NOTE The hole should be made at a slight downward slant on the outdoor side.
  • Page 12: Draining The Water

    Draining the Water Refrigerant Piping Connection Holes are provided on the base plate of the outdoor unit to ensure that the Flaring defrost water produced during heating operations is drained off effi ciently. If a centralized drain is required when installing the unit on a balcony or 1.
  • Page 13: Evacuating

    Packed valve handling precautions Evacuating Open the valve stem all the way out, but do not try to open it beyond the stopper. After the piping has been connected to the indoor unit, you can perform the air purge together at once. Pipe size of Packed Valve Size of Hexagon wrench AIR PURGE...
  • Page 14: Electrical Works

    ELECTRICAL WORKS The power supply can be selected to connect to indoor unit or outdoor unit. Choose proper way and connect the power supply and connecting cable by follow the instruction as following. RAS-B18G3KVSG-E RAS-B22G3KVSG-E RAS-B24G3KVSG-E RAS-B18G3KVSGB-E RAS-B22G3KVSGB-E RAS-B24G3KVSGB-E Power source 50Hz, 220 –...
  • Page 15: In Case Of Indoor Unit Connect With 1:1 Outdoor Unit

    In Case of Indoor Unit Connect With 1:1 Outdoor Unit Power Supply Input at Outdoor Unit Terminal Block (Recommend) Indoor Unit Outdoor Unit Connecting cable Stripping length of the Connecting cable connect to connecting cable 1 2 3 Terminal block (L N 1 2 3) Earth line 50 mm 10 mm...
  • Page 16 Power supply input Wiring Diagram for 1:1 Outdoor Unit Power input at Outdoor Terminal Block (Recommend) Indoor Chassis Terminal Block Chassis Outdoor Terminal Block Power input Power input at Indoor Terminal Block (Optional) Indoor Chassis Terminal Block Power input Chassis Outdoor Terminal Block...
  • Page 17: In Case Of Indoor Unit Connect With Inverter Multi System (Ims)

    In Case of Indoor Unit Connect With Inverter Multi System (IMS) Power Supply Input at Outdoor Unit Terminal Block Indoor Unit Outdoor Unit Connecting cable Stripping length of the Connecting cable connect to 1(L) 2 3 connecting cable Terminal block (L N 1 2 3) Earth line 50 mm 10 mm...
  • Page 18: Others

    OTHERS Gas Leak Test Test Operation To switch the TEST RUN (COOL) mode, press [RESET] button for 10 seconds. (The beeper will make a short beep.) Check places for the indoor unit. OPERATION / RESET Button Check places for the outdoor unit. Auto Restart Function Setting This product is designed so that, after a power failure, it can restart Check the fl are nut connections for the gas leak with a gas leak detector...