Technical data
8.1
Technical specifications
Table 8- 1
Technical data, MASS 2100, Di 3,6,15,25 and 40.
Versions
Inside pipe diamter (sensor
consists of one pipe)
Pipe wall thickness
Massflow measuring range
Density
Fraction, e.g.
Temperature
Pressure of liquid in
measuring pipe
1)
Stainless steel
Hastelloy C-22
Materials (Measuring pipe,
flange and thread
connection)
Enclosure and enclosure
material
Cable connection
EX-version
2)
Weight, approx. (Sensor
only)
1) Max. at 20°C, DIN 2413, DIN 17457
2) Intrinsic safety certification CENELEC and ASEV
Table 8- 2
Process connections
Versions
mm (inch)
Flange
EN 1092-1 PN40
ANSI B16,5, Class 150
ANSI B16,5 Class 600 (Class 300)
Dairy screwed connection (PN 16/25/40)
DIN 11851
SITRANS F C MASS 2100 Di 3-40
Operating Instructions, 07/2010, SFIDK.PS.028.Z1.02
mm (inch)
DI 3 (1/8)
mm (inch)
3.0 (0.12)
mm (inch)
0.5 (0.02)
kg/h (lb/inch
)
0 ... 250
3
(0 ... 500)
g/cm
3
°Brix
°C (°F)
bar (psi)
230 (3336)
bar (psi)
350 (5076)
1.4435/1.4404 (AISI 316L) (stainless steel)
•
2.4602 (Hastelloy C-22) (only Di 3, 6 ,15 and 25)
•
IP 65 (NEMA 4)
•
W 1.4404 AISI 316L) (stainless steel)
•
Note: Sensor enclosure not rated for pressure containment
Multiple connector to sensors 5 x 2 x 0.35 mm
12 mm
kg (lb)
4 (8.8)
DI 3 (1/8)
DN 10
1/2"
1/2"
1)
DN 10
DI 6 (¼)
DI 15 (5/8)
6.0 (0.24)
14.0 (0.55)
1.0 (0.04)
1.0 (0.04)
0 ... 1000
0 ... 5600
(0 ... 2200)
(0 ... 12345)
0 ... 2.9 (0 ... 0.10)
0 ... 100
-50 ... +180 (-58 ... +356)
265 (3844)
130 (1885)
410 (5946)
200 (2900)
twisted and shielded pairs, external diameter
2,
EEx ia IIC T3-T6
8 (17.6)
12 (26.5)
DI 6 (¼)
DI 15 (5/8)
DN 10
DN 15
1/2"
1/2"
1/2"
1/2"
DN 10
DN 15
8
DI 25 (1)
DI 40 (1½)
29.7 (1.17)
43,1(1.70)
2,0 (0.08)
2,6 (0.10)
0 ... 25000
0 ... 52000
(0 ... 55100)
(0 ... 114600)
110 (1595)
105 (1523)
185 (2683)
-
48 (105.8)
70 (154.5)
DI 25 (1)
DI 40 (1½)
DN 25
DN 40
1"
1 1/2"
1"
1 1/2"
DN 25
DN 40
33