hit counter script

Advertisement

LHN‑UC15L‑SIP | LHN‑UC15W‑SIP |
AMN‑P15‑SIP
en
User manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch LHN-UC15L-SIP

  • Page 1 LHN‑UC15L‑SIP | LHN‑UC15W‑SIP | AMN‑P15‑SIP User manual...
  • Page 3: Table Of Contents

    Table of contents | en Table of contents Safety Safety information Disposal instructions FCC statement - Wired Class B digital device (unintentional radiator) FCC suppliers Declaration of Conformity Installation LHN-UC15L-SIP or LHN-UC15W-SIP IP Horn loudspeaker 2.1.1 Considerations 2.1.2 Mounting 2.1.3 Connections 2.1.4 Microphone 2.1.5...
  • Page 4 | Table of contents LHN‑UC15L‑SIP | LHN‑UC15W‑SIP | AMN‑P15‑SIP LHN-UC15W-SIP Horn loudspeaker 15W, wide angle, SIP LHN-UC15L-SIP Horn loudspeaker 15W, long throw, SIP AMN-P15-SIP Amplifier module 15W, SIP 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 5: Safety

    Warning! To prevent a shock hazard disconnect all power sources prior to system installation. 13. Only use recommended batteries and observe polarity. Risk of explosion if an incorrect type of battery is used. Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 6: Disposal Instructions

    FCC statement - Wired Class B digital device (unintentional radiator) Changes or modifications not expressly approved by Bosch could void the user’s authority to operate the equipment. Class B digital device: FCC NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 7: Fcc Suppliers Declaration Of Conformity

    This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. Responsible party Bosch Security Systems LLC 130 Perinton Parkway 14450 Fairport, NY, USA www.boschsecurity.us Bosch Security Systems B.V.
  • Page 8: Installation

    LHN‑UC15L‑SIP | LHN‑UC15W‑SIP | AMN‑P15‑SIP Installation This chapter shows you the steps necessary to install the IP Horn loudspeaker and the IP Amplifier module. LHN-UC15L-SIP or LHN-UC15W-SIP IP Horn loudspeaker 2.1.1 Considerations Before installing the IP Horn loudspeaker, consider the following: Mounting location: The IP Horn loudspeaker must be fixed to a stable and suitable surface to support its weight.
  • Page 9: Connections

    A solid green LED (right) indicates the port is operating at 1000 Mbps (1 Gbps). It flickers to indicate network activity. – An orange/yellow LED (left) indicates a network link of 100 Mbps. It flickers to indicate network activity. Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 10 – For supervised input, use 0.75 1.25 V Connecting the analog Audio (Figure 2.2, callout 3) Notice! Connect the IP Horn loudspeaker using shielded cables that are properly grounded. 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 11 Align the cover with the screw holes, with the cable glands facing downwards. Using a T20 Torx screwdriver, tighten the four cover screws with a torque of 1.3 - 1.8 Nm. Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 12: Microphone

    IP Horn loudspeaker: Figure 2.3: Integrated microphone physical switch On/Off switch Switches the microphone on and off (Figure 2.3, callout 1). Notice! By default, the microphone is enabled 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 13: Physical Reset Button

    The LED next to the test button flashes slowly (1 Hz) if the test is successful and quickly (4 Hz) when it is unsuccessful. Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 14: Amn-P15-Sip Ip Amplifier Module

    To mount the IP Amplifier module to a solid surface: Remove the cover by pressing the two latches on the top of the cover (1). The cover disengages from the IP Amplifier module (2). 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 15 Using four screws with less than 5 mm diameter (not supplied), attach the IP Amplifier module to the surface. Align the cover tabs with the clamp holes on the IP Amplifier module. Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 16 To mount the IP Amplifier module in a DIN rail: Using the two TX20 screws (supplied), attach the DIN rail mounting plate to the back of the TX20 IP Amplifier module with a torque of 2.0 - 2.5 Nm. 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 17: Connections

    PoE switch for a convenient installation. For the most reliable operation, always use shielded CAT-5e or higher class cables. Notice! The IP Amplifier module shall be connected using shielded network cables that are properly grounded. Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 18 For supervised input, use 0.75 1.25 V Connecting the analog Audio (Figure 2.5, callout 3) Notice! The IP Amplifier module shall be connected using shielded cables that are properly grounded. 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 19 Connecting the passive loudspeaker (Figure 2.5, callout 4) The IP Amplifier module allows you to connect passive loudspeakers from an impedance of 4 Ohms to an impedance of 8 Ohms. For example: Passive loudspeaker basic connection Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 20: Physical Reset Button

    2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 21: Getting Started

    Do not disconnect the device while the update is running. If the update fails, disconnect the device and connect it again. Repeat the update process. Notice! Performing a firmware update keeps the device's configuration. Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 22: Ip Address Detection

    Below are two options on how you can get the IP address of the device. With the Bosch Configuration Manager You can quickly discover the IP address of your device using the Bosch Configuration Manager. You can download this software from https:// downloadstore.boschsecurity.com.
  • Page 23: Logon With The Web Browser

    Enter your username and password. Login to the web interface. You can also access the web-GUI of the device via the Bosch Configuration Manager. To do so: On the navigation bar, click the Network Scan button. Right-click the selected device, then click Show in Web Browser….
  • Page 24: Web-Gui Configuration

    To manage security for the device. Maintenance, page 37 To manage and maintain the device. Logging, page 39 To view and manage logging events. Logout, page 39 To log out of the web application. 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 25: Generic Settings

    Once the user account is created, you can only modify the password. It is not possible to change the user group. If the user needs to have a different user group, delete the account and create a new profile with the new user group assignment. Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 26: Sip

    The Username and Password need to match to the SIP server's dedicated account for the device. – You must select the Transport protocol. – You must assign an IP address of the SIP server in the Registrar. 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 27 Figure 4.1: Connection to IP-PBX system Notice! For a correct functionality, every SIP account requires at least one rule referencing the account. For more information, see Rules, page 31 . Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 28: Audio

    Delay Network Audio In (SIP) Figure 4.3: DSP signal flow diagram for IP Amplifier module To display the advanced audio settings, enable the Advanced view on Maintenance, page 37 . 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 29: Basic Audio Settings

    + or - to increase or decrease the values, or by moving a point in the plot graph. A Reset to default button, located at the top of the page resets the values to the default settings. Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 30: Advanced Audio Settings

    Practical example: Starting at a noise of -40 dBFS, the adaption shall raise the volume equally to the noise getting louder, not more than 20 dB. – Set Threshold to -40 dBFS. – Keep Ratio at 1.0. – Set Gain max (dB) to 20. 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 31: Messages

    Action settings To find an existing rule quickly, use the search field at the top of the page. Simply enter the name of the rule and click the button. Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 32: Name And Priority

    37 , under Virtual GPIs or by using the API. You can combine this trigger type with a schedule via Schedule type, if applicable. Otherwise, keep the default setting of Always. 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 33 The repetition count setting affects the message play behavior, see Figure 4.4. If disabled, the action stops immediately when the trigger finishes. Notice! The scheduled types only work properly if the device is synchronized with an NTP server. Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 34: Action Settings

    You can manually adjust the gain of individual messages via the Gain (dB) field. You can also define a GPO Action that runs when the trigger action is present. 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 35 The device has 1 physical GPO which may be connected using a separate cable and 16 virtual GPOs, which can been seen on Maintenance, page 37 , under API interface. Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 36: Certificates

    To select from the certificates available, first generate them in Certificates, page 36 . Click Save to save and apply your preferences. Notice! This can lead to a restart of the User interface 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 37: Maintenance

    To run any of these tests, click the button Start test. The table displays the results. Notice! You can only run the tests if all device rules are inactive. Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 38: User Interface Settings

    The Download system logs button downloads and saves system log files (syslogs.tar.gz) to your computer. Download firmware licenses button The Download firmware licenses button saves a file containing the open source licenses (opensourcelicenses.tar.gz file) to your computer. 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 39: Logging

    A time control either via NTP by DHCP or via a separate NTP server is required to properly use the Logging function. Otherwise the logs may display random timestamps. 4.12 Logout Click the Logout button to log out of the current session. Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 40: Https Rest Api

    – Set the physical GPO to follow any actions defined on the Rules page. You can obtain more information on GPIs, GPOs, and further parameters in detail on https://<IP_Address>/build/api/index.html. 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 41: Direct Bosch Camera Integration Via Atsl

    Using the camera's Alarm Task Scripting Language (ATSL) you can create a direct integration between a Bosch camera and an IP Horn loudspeaker or IP amplifier module. The VGPI of the IP Horn loudspeaker/Amplifier module controls the action, often a message playback, starting or stopping it using this scripting.
  • Page 42 | Direct Bosch camera integration via ATSL LHN‑UC15L‑SIP | LHN‑UC15W‑SIP | AMN‑P15‑SIP Example Script In the example, the camera defines two areas that activate two different messages via VGPIs at the IP Horn loudspeaker/IP Amplifier module. HttpCommand sendHttpOn:={ Command("api/ext/v1/vgpis/1")SSL(true)Port(443)IP("10.30.201.236") Password("pwd12345")UserName(“API_username”)Method(POST)ForceBasicAuth(true)
  • Page 43: Technical Data

    G.711 (u-law and a-law), G.722, Opus Ports 1x RJ45 Analog audio input/output Type 1 line-level input, 1 line-level output; unbalanced Connector 3-pin screw terminals Wire gauge AWG 28 — AWG 14 Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 44 144 mm x 188 mm x 207 mm Dimension (HxWXD) (in) 5.67 in x 7.40 in x 8.15 in Weight (kg) 1.6 kg Weight (lb) 3.53 lb IP rating IP66 Color in RAL RAL 7035 Light gray 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 45 Storage temperature (°C) -40 °C — 70 °C Storage temperature (°F) -40 °F — 158 °F Operating relative humidity, non-condensing 5% — 95% LHN-UC15L-SIP Horn loudspeaker 15W, long throw, SIP Electrical Power transfer Power over Ethernet PoE IEEE 802.3af Class 3 PoE+ IEEE 802.3at Class 4 Power consumption <5 W in Idle...
  • Page 46 Off: Open collector (>10 MΩ to GND) Stored messages Uploadable Via web-GUI Capacity 300 MB Supported file formats WAV, channels: mono, stereo; sampling rates: 44.1 kHz, 48 kHz MP3, channels: mono, stereo; sampling rates: 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 47 Power transfer Power over Ethernet PoE IEEE 802.3af Class 3 PoE+ IEEE 802.3at Class 4 Power consumption <5 W in Idle <7 W at 1/8 of rated power <13 W at rated power Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 48 User PEQ (3 bands), Speaker PEQ (6 bands), Compressor, Autogain, Noisegate, Dynamic EQ, RMS-limiter, Peak limiter, Level, Mute, Delay GPIO Type Terminal block with screw terminals Connector 3-pin screw terminals 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 49 Weight (lb) 0.474 lb Ingress Protection (IP) IP30 Color Black DIN rail adapter Material Aluminum Environmental Climatic conditions Operating temperature (°C) -40 °C — 55 °C Operating temperature (°F) -40 °F — 131 °F Bosch Security Systems B.V. 2023.02 | V01 | F.01U.389.835 User manual...
  • Page 50 | Technical data LHN‑UC15L‑SIP | LHN‑UC15W‑SIP | AMN‑P15‑SIP Climatic conditions Storage temperature (°C) -40 °C — 70 °C Storage temperature (°F) -40 °F — 158 °F Operating relative humidity, non-condensing 5% — 95% 2023.02 | V01 | F.01U.389.835 Bosch Security Systems B.V. User manual...
  • Page 52 Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven Netherlands www.boschsecurity.com © Bosch Security Systems B.V., 2023 Building solutions for a better life. 202302171237...

Table of Contents