NAVIS WL11/WS Manual

NAVIS WL11/WS Manual

Wind logger

Advertisement

Quick Links

OPERATING
Sensors continuously measure and transmit data of wind speed, air temperature and wind direction (optionally).
Display unit receives data, calculates average values and stores them to the memory card. Current data, received
from sensor, as well as part of the wind speed history are presented on LCD display. All operating parameters can
be set using three keys on the receiver unit.
DISPLAYING OF DATA:
Shortly press key F to select between 4 pages
1. page - displays current wind speed, temperature, wind direction (optional), date and time
2. page - displays 7 days history of average and maximum wind speed
3. page - displays 24 h graph of hourly average wind speed
4. page - displays 24 h graph of hourly average temperature
SETTING OF PARAMETERS
Hold the F key pressed to enter the settings menu. Select the parameter you wish to change by using up and down
keys. Press the F key to enter in the selected parameter and change the value with up and down keys.
Press the F key to enter a new value into the permanent memory and move to the next parameter. When you have
set all the parameters, exit the settings menu by holding the F key pressed for 3 seconds.
DESCRIPTION OF PARAMETERS:
Time: 12:55
Date: 26/12/2015
Day: Sunday
WS Address: xx
WS units: m/s
0
Temperature unit:
C
Logging int: 1min
Display Auto Off: Yes
WS Cal. Factor: 0.0%
WD Cal. Factor: 0
0
0
Te. Cal. Factor: 0
Reset Data: No
Language: English
SENSOR UNIT
Sensor unit switches ON automatically when the anemometer cups revolve. It switches OFF 6 hours after the
anemometer cups stop revolving. In ON state position it sends new wind speed data every two seconds. In
sleep mode the sensor does not transmits any data.
SENSOR ADDRESS
Correspondent sensor address has already been preset at the factory.
Always set the address correspond to the address of the sensor from which the receiver will receive data. Address
of the sensor is indicated on the label and in the interior of battery compartment.
DISPLAY AUTO OFF
Activate this mode in the setting menu to prolong battery life. Using this mode, the display switches OFF after
2 minutes of inactivity. All other functions stay active. Display switches ON with each press of the key.
WIND LOGGER
MODELS: WL11/WS, WL11/WDS
time setting - 24 h time format
date setting - day/month/year
day setting
set the sensor address of your receiving sensor
wind speed unit (m/s, km/h, knots, mph)
0
temperature unit (
C or
logging interval (10 s, 1 min, 10 min or 60 min)
automatic display switching off (saving mode/ reducing power consumption)
Yes: display automatically switches off after 2 minutes
No: display is always ON
Calibration factor for wind speed (-15,0 ...+15,0%, in 0,5% steps)
Calibration factor for wind direction (-180
Calibration factor for temperature (-2.0
No/Yes
English/French
MANUAL
0
F)
0
...+180
0
0
...+2.0
0
, in 1
0
steps)
0
, in 0.5
steps)

Advertisement

loading

Summary of Contents for NAVIS WL11/WS

  • Page 1 WIND LOGGER MODELS: WL11/WS, WL11/WDS MANUAL OPERATING Sensors continuously measure and transmit data of wind speed, air temperature and wind direction (optionally). Display unit receives data, calculates average values and stores them to the memory card. Current data, received from sensor, as well as part of the wind speed history are presented on LCD display. All operating parameters can be set using three keys on the receiver unit.
  • Page 2 SIGNAL RECEPTION Reed LED blinks when the display unit receives a signal from the sensor (every 2 seconds if reception is good). Signal strength is numerically shown in dB: • -105 dB is approximately limit where display unit stops receiving •...
  • Page 3 Example of logged first 15 wind data from WSD sensor in 10s logging interval. Average wind speed [WS] and maximum wind speed [WSm] wind speed data are in units of m/s, temperature in degrees of celsius and wind direction [WD] in degrees. <---Wind Logger WL11 v.16032015---> <--------Navis Elektronika--------> <---------------------------------> <Logging Interval:10s-------------> <WS[m/s]--WSt[C]--WD[deg]--------->...
  • Page 4 Any liability for direct or indirect damage caused by product failure is excluded. The claimed product will be repaired or replaced only when returned to the store where it was purchased together with original invoice. 231116 __________________________________________________________________________________ NAVIS elektronika d.o.o., Poljska c.11, SI-1241 Kamnik, info@navis-elektronika.com, www.navis-anemometers.com...