Mounting the device
Before mounting and commissioning
IMPORTANT: observe all documents enclosed with the device and the operating instructions manual
before mounting and connecting the device. You can find the complete documentation of the device
on the enclosed USB stick and on the internet.
(http://www.siemens.com/simatic-ipc-doku-portal)
The manual symbol refers to detailed information in the operating instructions.
CAUTION
!
With a safety alert symbol, indicates that minor personal injury can result if proper precauions are
not taken.
Valid Mounting positions
At least 50 mm space has to be left free around the ventilation slot.
Installing the device
CAUTION
!
Risk of physical injury
The device is too heavy to be mounted exclusively with the 19 inch brackets of the front panel.
The device may fall down, injure people and get damaged.
Secure the device using additional measures. The mounting screws of the telescopic rails may not
protrude more than 5 mm into the device.
Mounting on angle brackets
nnecting the power
1
1
2
Mounting on telescopic rails
3 3
1
2
40 °C
5 °C
Mounting on device bases
1
1
2
1
Connecting the device
Connecting the function earth
2
1
M4
Connecting the power supply
CAUTION
!
The device is intended for operation on grounded power supply systems (TN systems according to IEC
60364-3). It is not designed for opertion on undergrounded or impedance-grounded power networks
(IT networks).
In case of connect the device to ungrounded or impedance-grounded power networks (IT networks),
there is a risk of electric shock, fire and burst.
Ensure the power supply system the device operating on is correctly grounded.
WARNING
!
Risk of electric shock when using a power connection without earth connection.
Using a mains cable without proper earth connection can result in personal injury or even death by
electric shock.
A mains cable is not included with IPC347G.
Make sure the cable you use provides a proper earth connection.
It is highly recommended that you use a mains cable from SIEMENS.
2
2
PH2
²
2.5mm
1