Page 1
Introduction Safety notices Security recommendations SIMATIC NET Description of the device Industrial Remote Communication Remote Networks Installation and removal SCALANCE MUM853-1 Operating Instructions Connection Troubleshooting Maintenance and cleaning Technical specifications Dimension drawings Approvals 03/2023 C79000-G8976-C650-05...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Industrial Ethernet ......................24 4.5.4 Flexible connecting cables, antennas and accessories ............26 Terminals........................... 27 LED display ........................28 Reset button ........................30 Configuration License PLUG....................31 Installation and removal........................33 Safety notices for installation ..................... 33 SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 4
Protection of health and safety ................... 80 11.2.2.2 EMC........................... 80 11.2.2.3 Efficient use of the radio spectrum ..................81 11.2.3 Other technical standards ....................82 11.3 Supplier’s declaration of conformity ................... 82 11.4 General approvals ......................83 Index ..............................87 SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
These operating instructions apply to the following firmware version: • SCALANCE M-800/S615 version 7.2 or later You will find the article numbers for the Siemens products of relevance here in the following catalogs: • SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI •...
Page 6
(https:// support.industry.siemens.com/cs/ww/en/view/84922825) SIMATIC NET manuals You will find SIMATIC NET manuals on the Internet pages of Siemens Industry Online Support: • using the search function: Link to Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/) Enter the entry ID of the relevant manual as the search item.
Check regularly for new firmware/software versions or security updates and apply them. After the release of a new version, previous versions are no longer supported and are not maintained. Error/fault If a fault develops, send the device to your SIEMENS representative for repair. Repairs on-site are not permitted. Decommissioning Shut down the device properly to prevent unauthorized persons from accessing confidential data in the device memory.
You will find license conditions in the following documents on the supplied data medium: • OSS_SCALANCE_MuM856_86.pdf 1.10 SIMATIC NET glossary The SIMATIC NET glossary describes terms that may be used in this document. You will find the SIMATIC NET glossary in the Siemens Industry Online Support at the following address: 50305045 (https://support.industry.siemens.com/cs/ww/en/view/50305045) 1.11 Trademarks The following and possibly other names not identified by the registered trademark sign ®...
Electric devices have hot surfaces. Do not touch these surfaces. They could cause severe burns. • Allow the device to cool down before starting any work on it. WARNING EXPLOSION HAZARD Do not open the device when the supply voltage is turned on. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
• For data transmission via a non-secure network, use an encrypted VPN tunnel (IPsec, OpenVPN). • Check the user documentation of other Siemens products that are used together with the device for additional security recommendations. • Using remote logging, ensure that the system protocols are forwarded to a central logging server.
Page 14
• Verify certificates based on the fingerprint on the server and client side to prevent "man in the middle" attacks. Use a second, secure transmission path for this. • Before sending the device to Siemens for repair, replace the current certificates and keys with temporary disposable certificates and keys, which can be destroyed when the device is returned.
Page 15
Implementation Information Disclosure Vulnerability (for example, BEAST). • Ensure that the latest firmware version is installed, including all security-related patches. You can find the latest information on security patches for Siemens products at the Industrial Security (https://www.siemens.com/industrialsecurity) or ProductCERT Security Advisories (https://www.siemens.com/cert/en/cert-security-advisories.htm) website.
Page 16
– Non authenticated and unencrypted interfaces – ICMP (redirect) – LLDP – DHCP Options 66/67 – SNTP – NTP – TFTP – TIA Portal Cloud Connector (not available with SCALANCE MUM85x) – VRRPv3 – DNS – SNMPv1/V2c SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
• Authentication Specifies whether an authentication of the communication partner takes place or whether an authentication can be configured. • Encryption Specifies whether the transfer is encrypted or whether the encryption can be configured. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 19
"Ciphers used". Only open with SCALANCE M826 Only open with SCALANCE S615 Only closed with SCALANCE S615 Not available with SCALANCE MUM85x Only available with the SCALANCE M87x and MUM85x Only available with SCALANCE MUM85x SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 20
Layer 2 service Default status Configurable Open (when configured) ✓ LLDP Open (when configured) ✓ SIMATIC NET TIME Open (when configured) ✓ VLAN Open (when configured) ✓ VXLAN Open (when configured) ✓ Only with SCALANCE MUM85x SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
The type designation of the device is made up of several parts that have the following meaning: Product characteristics Interfaces Functionality SCALANCE MUM853-1 Connectors for external antennas 4 x SMA connectors female Ethernet interface 4 x RJ45 connectors with 10/100/1000 Mbps...
On the bottom of the device behind the screw-on cover: • Reset button • PLUG slot (CLP) For the position, see "Reset button (Page 30)". ⑨ Antenna connector A2, type SMA female ⑩ Power supply connection ⑪ LED display SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
• One 2-pin plug-in terminal block for the digital output • A product DVD Please check that the consignment you have received is complete. If the consignment is incomplete, contact your supplier or your local Siemens office. Note Not included with the product The following components do not ship with the product: •...
4.5 Accessories Accessories Technical data subject to change. You will find further information on the range of accessories in the Industry Mall (https:// mall.industry.siemens.com/mall/en/WW/Catalog/Products/10022025) Use the TIA Selection Tool (https://mall.industry.siemens.com/tst/) for configuring the device. 4.5.1 Installation Component Description Article number DIN rail mounting adapter...
Page 25
Mbps) with rugged metal housing and FC connector technology, for IE FC Cable 4x 2 (24 AWG); 180° cable outlet 1 connector per package 6GK1901-1BB11-2AA0 10 connectors per package 6GK1901-1BB11-2AB0 50 connectors per package 6GK1901-1BB11-2AE0 SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Panel feedthrough for wall thicknesses up to a 6GK5798-0PT00-2AA0 Female Panel Feedthrough maximum of 5.5 mm, two N-Connect/SMA fe‐ male connectors N-Connect Female/Female Cabinet feedthrough for wall thicknesses up 6GK5798-2PP00-2AA6 Panel Feedthrough to 4.5 mm, two N-Connect female-female connectors SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Terminal block with two terminal con‐ nectors Terminals and wiring Connectors +DI, -DI /+D0, -DO L1, M1, L2, M2 28 AWG 16 AWG Wire end ferrule without plas‐ 0.2 mm 1.5 mm tic collar to DIN 46228/1 SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Possible errors/faults: • Wrong PIN number • The inserted CLP has an invalid or incompatible configuration Flashing red Firmware on CLP The device is performing a firmware update or downgrade. Interval: 2000 ms on / 200 ms SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 29
No reception or mobile wireless disabled Wrong PIN number or SIM card error Flashing red Signal strength very poor Flashing yel‐ Signal strength poor Signal strength medium Flashing Signal strength good green Green Signal strength very good SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
When the cover is not mounted correctly, the device loses its degree of protection IP30. The Reset button is located behind the screw-on cover on the underside of the housing. ① PLUG slot (CLP) ② Reset button SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
• PLUG License: In addition to the configuration data, the exchangeable storage medium contains a license with which special functions are enabled, e.g. iFeatures. NOTICE Loss of the degree of protection When the cover is not mounted correctly, the device loses its degree of protection IP30. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 32
– The configuration data of the device is stored in a secured memory area of the CLP. This secured memory area can only be accessed via the authentication of the Siemens device. – The device checks whether a CLP is inserted at one second intervals. If the device detects that the CLP has been removed, it restarts automatically.
50 °C. WARNING The device is intended for indoor use only. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 34
To comply with EU Directive 2014/34 EU (ATEX 114), UK-Regulation SI 2016/1107 or the conditions of IECEx or CCC-Ex, the housing or cabinet must meet the requirements of at least IP54 (according to EN/IEC 60529, GB/T 4208) in compliance with EN IEC/IEC 60079‑7, GB 3836.3. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 35
• Installation in a suitable cabinet. • Installation in a suitable enclosure. • Installation in a suitably equipped, enclosed control room. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
• Vertical mounting position (ventilation openings at the top and bottom) • Horizontal mounting position (ventilation openings to the right and left) You can find information about the ambient temperature under Permitted ambient conditions. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
The wall mounting must be capable of supporting at least four times the weight of the device. Use suitable fittings depending on the mounting surface. Requirement The SIM card is inserted. You can find more information on this in the section "SIM card (Page 59)". SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 38
Installation and removal 5.3 Wall mounting Drilling template The figure shows the location of the holes for wall mounting of the device: SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
The type and length of the screws depend on the type of wall. 3. Connect the device; see section "Connecting (Page 45)". Installing on the DIN rail Requirement The SIM card is inserted. You can find more information on this in the section "SIM card (Page 59)". SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 40
3. If necessary, loosen the knurled screw with your hand or a screwdriver. 4. Using a screwdriver, pull down the catch on the rear of the device. 5. Pull lower part of the device away from the DIN rail. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
4. With the securing bar pulled, swivel the device to the mounting rail and press it against the mounting rail until the spring-mounted securing bar locks into place. 5. Tighten the knurled screw to secure the device additionally (torque 0.5 Nm). 6. Connect the device; see section "Connecting (Page 45)". SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
5. Remove the device from the mounting rail with the bar pulled. Installing on an S7-1500 mounting rail Requirement The SIM card is inserted. You can find more information on this in the section "SIM card (Page 59)". Installation SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 43
3. If necessary, loosen the knurled screw with your hand or a screwdriver. 4. Using a screwdriver, pull the securing bar down as far as it will go. 5. Remove the device from the mounting rail with the bar pulled. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 44
Installation and removal 5.6 Installing on an S7-1500 mounting rail SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
If the device is connected to a redundant power supply (two separate power supplies), both must meet these requirements. WARNING Insulation of external power supplies Ext. circuits intended to be connected to this device shall be galv. separated from hazardous live voltage by reinforced or double insulation. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 46
Safety extra low voltage The device is designed for operation with a directly connectable safety extra-low voltage (SELV) according to UL/IEC 61010-1 and UL/IEC 61010-2-201 whose output power corresponds to "Limited Energy" according to UL/IEC 61010-1. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 47
Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Do not connect or disconnect cables to or from the device when a flammable or combustible atmosphere is present. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 48
There is a risk of explosion due to equalizing currents between the hazardous area and the non- hazardous area. • Ground shielded cables that cross hazardous areas at one end only. • Lay a potential equalization conductor when grounding at both ends. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 49
DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS. WARNING Restricted area of application This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous locations only. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
The device can be disconnected from the power supply by removing the terminal block. The power supply is connected using a 5-pin plug-in terminal block. The power supply is non-floating. Contact Assignment 24 VDC Ground Ground SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
24 VDC: BVT AVD 24 type no. 918 422 Vendor: DEHN+SÖHNE GmbH+Co.KG, Hans Dehn Str. 1, Postfach 1640, D - 92306 Neumarkt, Germany Ethernet The device has four Ethernet interfaces located on the front of the device. Connection to Industrial Ethernet uses RJ45 connection technology with MDI-X assignment. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 52
The following table shows the pin assignment of the RJ45 connectors. Pin number Pin assignment RJ45 connector 10/100/1000 Mbps Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Connection 6.4 Antennas Antennas The SCALANCE MUM853-1 has 4 antenna ports of the type SMA female. Note Use the antennas from the range of accessories for the device. You will find more detailed information in "Accessories (Page 26)". If you use a different antenna, there is no guarantee that the device will function according to the specification.
Page 54
An antenna must always be connected to the antenna connectors in order to use 3/4/5G connectivity. • A3+A4 Optional. The antenna connectors are required for additional MIMO download streams. If you want to use GNSS, connect an antenna with a clear view of the sky to A4. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 55
(Connect an antenna to the antenna connector A4 for use) Depending on the frequency bands used by your mobile wireless provider, antennas must be tuned to the suitable frequencies. Check with your mobile wireless provider for the frequency bands. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Damage due to voltage being too high or too low The voltage at the digital input/output must not exceed 30 VDC and not fall below -30 VDC, otherwise the digital input/output will be destroyed. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 57
The 2-pin terminal block has the following assignment: Contact Assignment Input Ground If there is an adequate switching voltage at the digital input, the digital input is active and the "DI" LED is lit. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 58
+13 to +30 V DC Digital output The 2-pin terminal block has the following assignment: Contact Assignment Switching signal Relay 24 V DC / 0.5 A Ground The output is a switch that switches the signal at +DO to ‑DO. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Do not open the SIM card tray during operation. This can damage the SIM card and the device. Position The tray for the micro SIM card is located on the back of the device. The tray is secured with an M3 screw. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 60
4. Then push the tray with the SIM card completely back into the housing. ③ 5. Place the cover on the opening as shown in the picture. ④ 6. Carefully tighten the M3 screw with a torque of max. 0.4 Nm. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
2. Loosen the screws M3 with a Torx screwdriver T10 and remove the slot cover ③ 3. To release the CLP , insert a screwdriver between the front edge of the CLP (A) and the slot. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 62
Note this orientation when inserting the CLP. ③ Insert the CLP in the correct orientation into the slot. 4. Close the slot cover (torque 0.8 Nm) to ensure that the device maintains the degree of protection IP30. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Downloading new firmware using TFTP without WBM and CLI Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. You can download new firmware to the device using TFTP. To do this, the device does not need to be reachable either using Web Based Management (WBM) or using the Command Line Interface (CLI).
Follow the steps below to reset the device parameters to the factory settings with the SINEC PNI: 1. Select the device whose parameters you want to reset. 2. Click the "Reset device" button. 3. Select the "Reset to factory settings" option in the following dialog. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 65
Via the configuration You will find detailed information on resetting the device parameters using the WBM and CLI in the configuration manuals: • Web Based Management, section "Restart" • Command Line Interface, section "Reset and Defaults" SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Maintenance and cleaning WARNING Unauthorized repair of devices in explosion-proof design Risk of explosion in hazardous areas • Repair work may only be performed by personnel authorized by Siemens. WARNING Impermissible accessories and spare parts Risk of explosion in hazardous areas •...
Technical specifications The following technical specifications apply to the SCALANCE MUM853-1. Technical specifications Data transfer Ethernet transmission rate 10/100/1000 Mbps Wireless transmission rate • Downlink: up to 1000 Mbps • Uplink: up to 500 Mbps • Downlink: up to 1000 Mbps • Uplink: up to 200 Mbps UMTS •...
Page 70
< 30 m Cables should be routed in pairs Properties Output isolated from electronics Permitted ambient conditions Ambient temperature During operation -30 °C to +60 °C During storage -40 °C to +85 °C During transportation -40 °C to +85 °C SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 71
To establish a VPN (Virtual Private Network), the following functions are available: – Up to 20 connections – IPsec VPN, OpenVPN (as client) • SINEMA RC client • Proxy server • Siemens Remote Service (SRS) SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 72
Dynamic DNS client • DNS client and DNS proxy • SMTP client • Location determination via GPS • Geofencing • eSIM (as of hardware version 2) • Secure Boot (as of hardware version 2) SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
The Industry Image Database page is loaded. 2. Enter the name or article number of the product in the search filter. You can refine your search using the "Motif type" selection list. Note Dimensions are specified in mm. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
15982/cert) National approvals You can find an overview of the country-specific wireless approvals of SIMATIC NET devices on the Internet pages of Siemens Industry Online Support. You can find the link to the document on the following page ik-Info (https://www.siemens.com/mobilenetwork-approvals) Installation guidelines...
Process Automation DE-76187 Karlsruhe Germany You can find the current EU declaration of conformity for these products on the Internet pages under Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15982/cert). The products described in this document meet the requirements of the following EC directives: •...
- Part 1: Common technical requirements • ETSI EN 301 489‑52 Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 52: Specific conditions for cellular communication mobile and portable (UE) radio and ancillary equipment SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Radio (NR) User Equipment (UE) Release 15 • ETSI EN 303 413 Satellite Earth Stations and Systems (SES) - Global Navigation Satellite System - Radios for operation in the frequency bands from 1164 MHz to 1300 MHz and from 1559 MHz to 1610 MHz SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Manchester M20 2UR United Kingdom You can find the current UK Declaration of Conformity for these products on the Internet pages under Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15982/cert). The SIMATIC NET product described in these operating instructions meets the requirements of the following directives: •...
Industrial, scientific and medical (ISM) radio-frequency equipment – Electromagnetic dis‐ turbance characteristics – Limits and methods of measurement • ETSI EN 301 489‑1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic com‐ patibility for radio equipment and services - Part 1: Common technical requirements SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Radio (NR) User Equipment (UE) Release 15 • ETSI EN 303 413 Satellite Earth Stations and Systems (SES) - Global Navigation Satellite System - Radios for operation in the frequency bands from 1164 MHz to 1300 MHz and from 1559 MHz to 1610 MHz SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Process Automation DE-76187 Karlsruhe Germany You can find the current Supplier's declaration of conformity for these products on the Internet pages under Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15982/cert) As required by the following Notices: • Radiocommunications (Compliance Labelling - Devices) Notice 2014 made under section 182 of the Radiocommunications Act 1992;...
"SIMATIC NET Product Information Use of subassemblies/modules in a Zone 2 Hazardous Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages under Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/view/78381013).
Page 84
• UL 121201 (Non Incendive electrical equipment) approved for use in Class I, Division 2, Groups A, B, C, D, T4. • UL CSA C22.2 NO 213 (Non Incendive electrical equipment) approved for use in Class I, Zone 2, Group IIC, T4. SCALANCE MUM853-1 Operating Instructions, 03/2023, C79000-G8976-C650-05...
Page 85
• Telecommunications (Labelling Notice for Customer Equipment and Customer Cabling) Instrument 2015 made under section 407 of the Telecommunications Act 1997 You can find the current declaration of conformity for these products on the Internet pages under Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/ 15914/cert)
Page 86
Products Product name Standards Australia New Zealand SCALANCE MUM853-1 Marking for the customs union EAC (Eurasian Conformity) Eurasian Economic Union of Russia, Belarus, Armenia, Kazakhstan and Kyrgyzstan Declaration of conformity according to the technical regulations of the customs union (TR ZU) Brazil Para maiores informações, consulte o site da ANATEL –...