SAFETY INSTRUCTIONS Please read the instructions carefully before using the equipment. To use the equipment correctly, do not attempt to install, operate, maintain, or inspect the equipment until you have read through this manual, installation guide, and appended documents carefully. Do not use the equipment until you have a full knowledge of the equipment, safety information and instructions.
Page 4
[Installation/wiring] WARNING ● To prevent an electric shock, turn off the power and wait for 15 minutes or more before starting wiring and/or inspection. ● To prevent an electric shock, ground the servo amplifier. ● To prevent an electric shock, any person who is involved in wiring should be fully competent to do the work.
ABOUT THE MANUAL e-Manuals are Mitsubishi Electric FA electronic book manuals that can be browsed with a dedicated tool. e-Manuals enable the following: • Searching for desired information in multiple manuals at the same time (manual cross searching) • Jumping from a link in a manual to another manual for reference •...
Outline Motion mode Motion mode is used with a controller supported by a CANopen profile. Combining with Mitsubishi Electric manufactured Motion modules enables advanced motion control such as positioning of multiple axes, synchronous control by sequential command or interpolation control. The positioning function built-in servo amplifier can be used for positioning operation.
Function list Communication-related function list (Application) Category Subcategory Function Description Details Detailed explanation Page 7 Network Open network CC-Link IE TSN This servo amplifier supports CC-Link IE TSN. communication protocol Communication specifications Page 10 Startup CC-Link IE TSN Network configuration settings and station-specific mode selection communication setting are performed by using GX Works3.
*2 There are restrictions on the communication cycle depending on the function used. For details, refer to "Function restrictions" in the following manual. MR-J5-G/MR-J5W-G User's Manual (Introduction) *3 The communication speed can be set to 1 Gbps or 100 Mbps. 100 Mbps can be used with servo amplifiers with firmware version B6 or later.
MR-J5-G/MR-J5W-G User's Manual (Object Dictionary) 2000h to 5FFFh Objects group defined by Mitsubishi Electric 6000h to 9FFFh CiA 402 drive profile The classification of the objects defined by Mitsubishi Electric is as follows. Index Description Reference MR-J5-G/MR-J5W-G User's Manual (Object 2000h to 27FFh...
For details about objects that can be stored in the non-volatile memory, refer to the following. MR-J5-G/MR-J5W-G User's Manual (Object Dictionary) ■Store parameters Writing "65766173h" (= reverse order of the ASCII code "save") to [Store parameters (Obj. 1010h: 01h)] enables the setting value of an object to be stored in the non-volatile memory of the servo amplifier.
Network connection procedure Page 11 Network connection procedure Settings when connecting to Mitsubishi Electric Motion Unit To control the stroke limit on the controller side, set [Pr. PD41]. For details, refer to the manual for the controller being used. Servo parameter Name PD41.2...
Page 13
Network connection procedure Follow the procedures below to set up the network. Connect the master station and the servo amplifier with a network cable. There is no difference between CN1A and CN1B. Turn on the power of the master station and the servo amplifier. Open the diagnostic screen of GX Works3 and make sure that there is no error in the network.
Application function CC-Link IE TSN Network diagnostics The servo amplifier supports the following CC-Link IE TSN Network diagnostic functions. Check the reference destination in the reference column for precautions specific to the servo amplifier. Refer to the GX Works3 manual for details of other functions.
IP address setting function IP addresses are delivered from the controller to servo amplifiers via CC-Link IE TSN. Set the IP address required for CC-Link IE TSN communication from the following items. The IP address range is between 0.0.0.1 and 223.255.255.254. Set the IP address within the range. [Pr.
Parameter automatic setting The parameters of the servo amplifier are held by the master station, and are compared with those of the replaced servo amplifier. When there is a difference in those parameters, the parameters held by the CPU module are automatically written to the replaced servo amplifier.
Hold/Clear of output at CPU STOP and at CPU stop error This function sets Hold/Clear of the auto refresh device output when CPU module operation of the cyclic master is at STOP or at CPU stop error. The following shows the servo amplifier status at CPU STOP and at stop error. Motion mode ■Motion control axis The servo amplifier stops the servo motor in the manner commanded by the controller.
APPENDIX CC-Link IE TSN CC-Link IE TSN communication protocol Communication management The communication state of the slave unit in CC-Link IE TSN is broadly classified as being either an "initialization phase" or an "under control communication phase" and then managed. ■Communication state management of the motion mode The motion mode of the servo amplifier support CANopen profile.
Page 19
The controller and the servo amplifier perform the following procedure to establish communication (transition to "Operational"). Transition No. Operation Power-on During the transition from the initialization phase to the control communication phase of CC-Link IE TSN, the servo amplifier transitions from "Init"...
Cyclic transmission Cyclic transmission is a function that cyclically exchanges data between stations. Cyclic transmission of motion mode Cyclic transmission of the motion mode is a function that uses PDOs to cyclically exchange data between stations. A PDO is an aggregate of objects such as [Modes of operation (Obj. 6060h)] and [Modes of operation display (Obj. 6061h)]. The placement of objects in a PDO is called PDO mapping, and the initial placement (default PDO mapping) is defined.
Page 21
■Default PDO mapping Default PDO mapping is the initial placement of objects included in a PDO. When there is no request from the controller or the engineering tool to change PDO mapping objects, the servo amplifier operates using default PDO mapping. •...
Page 22
• RPDO, TPDO 2nd mapping ([2nd Receive PDO Mapping (Obj. 1601h)] and [2nd Transmit PDO Mapping (Obj. 1A01h)]) PDO mapping for the motion mode (high-speed). RPDO (from the master station to the servo amplifier) Offset Address Index Device name 0000h 1D01h Watch dog counter DL 0002h...
Page 23
• RPDO, TPDO 3rd mapping ([3rd Receive PDO Mapping (Obj. 1602h)] and [3rd Transmit PDO Mapping (Obj. 1A02h)]) PDO mapping for profile mode operation (pp/pv/tq/hm). RPDO (from the master station to the servo amplifier) Offset Address Index Device name 0000h 6060h Modes of operation 0001h...
Page 24
• RPDO, TPDO 4th mapping ([4th Receive PDO Mapping (Obj. 1603h)] and [4th Transmit PDO Mapping (Obj. 1A03h)]) PDO mapping for positioning mode (pt/jg/hm). RPDO (from the master station to the servo amplifier) Offset Address Index Device name 0000h 6060h Modes of operation 0001h 0000h...
Page 25
■PDO mapping objects The placement of objects in a PDO can be changed with PDO mapping objects ([1st Receive PDO Mapping (Obj. 1600h)] to [4th Receive PDOMapping (Obj. 1603h)] and [1st Transmit PDO Mapping (Obj. 1A00h)] to [4th Transmit PDO Mapping (Obj. 1A03h)]).
Page 26
• PDO mapping objects between the master station and the servo amplifier When changing the PDO mapping between the master station and the servo amplifier, use [1st Receive PDO Mapping] to [4th Receive PDOMapping] for the RPDO and [1st Transmit PDO Mapping] to [4th Transmit PDO Mapping] for the TPDO. Index Object Name...
Page 27
• PDO mapping setting procedure When a motion module is used as the motion control axis, the mapping is automatically changed on the motion module side. Using [1st Receive PDO Mapping (Obj. 1600h)] and [1st Transmit PDO Mapping (Obj. 1A00h)] as examples, the following shows the procedure for setting objects one at a time.
Page 28
■Objects that require PDO mapping • Objects that require RPDO mapping, categorized by control mode and function : PDO mapping required : PDO mapping recommended : PDO mapping not required Object name (Index) Mode [Watch dog counter DL (Obj. 1D01h)] ...
Page 29
• Objects that require TPDO mapping, categorized by control mode and function : PDO mapping required : PDO mapping recommended : PDO mapping not required Object name (Index) Mode [Watch dog counter UL (Obj. 1D02h)] [Statusword (Obj.
Page 30
■Watchdog counter The watchdog counter can be used to detect application stop of the cyclic transmission station. When a watchdog counter object is mapped to the RPDO of the servo amplifier, [AL. 086.2 Network communication error 2] is detected on the servo amplifier side.
Page 31
• Initial value of PDO configuration object The initial values of PDO configuration objects ([1st PDO Config (Obj. 1C00h)] and [2nd PDO Config (Obj. 1C01h)]) are different for Motion mode and Motion mode (high-speed) as shown in the following table. Index Name Default...
Transient transmission The transient transmission is a function that communicates data only when there is a communication request. Data communication is performed between stations by using SLMP and other protocols, regardless of the communication cycles. For CC-Link IE TSN, transient transmission and cyclic transmission are performed using different communication bands in order to ensure the stability of the cyclic transmission.
Page 33
PDS state transitions The internal state of the servo amplifier is managed by the PDS state defined in the CiA 402 drive profile specification. The servo motor can be operated immediately after turning on the power supply by shifting from the "Not ready to switch on" state to the "Operation enabled"...
Page 34
Events and PDS state transitions Setting Controlword enables control of the state transitions. After the PDO communication is established (after the NMT state has reached "Operational"), the status is controlled by the master station transmitting commands (by setting Controlword) in accordance with the following table. Each axis of the multi-axis servo amplifier supports the PDS state.
Page 35
The following shows the related correspondence between the command bit setting and the PDS state. In order to avoid missing the command at the time of communication error, maintain the state of Bit 7 = 1 on the Fault Reset command for at least 10 ms when the communication cycle is 4 ms or less, or at least 20 ms when the communication cycle is 8 ms.
Page 36
2D00h ARRAY Supported Control DI 10 Correspondence information for Control DI 10 2D01h Control DI 1 Objects defined by Mitsubishi Electric 2D0Ah Control DI 10 Objects defined by Mitsubishi Electric ■Bit definition of Controlword Symbol Description Reference Switch On Page 32 Events and PDS...
Page 37
■Bit definition of Control DI With the communication function, reading the following objects enables reading of the on/off state of the input device. In addition, the input device can be set to on/off by writing to the following objects. • Control DI 1 Symbol Description Reference...
Page 38
• Control DI 3 Symbol Description Reference The value at reading is undefined. Set "0" when writing. ...
Page 39
• Control DI 5 Symbol Description Reference The value at reading is undefined. Set "0" when writing. C_CDP2 Gain switching 2 Refer to "Signal (device) explanations" in the following manual. MR-J5 User's Manual (Hardware) ...
Page 40
• Control DI 7 Symbol Description Reference The value at reading is undefined. Set "0" when writing. ...
Page 41
• Control DI 9 Symbol Description Reference The value at reading is undefined. Set "0" when writing. ...
Page 42
The Statusword objects and the Status DO x objects notify the master station of the PDS state and other drive states. States defined by CiA 402 are notified by using [Statusword (Obj. 6041h)], and other states defined by Mitsubishi Electric are notified by using [Status DO 1 (Obj.
Page 43
• State coding Bit 0 to Bit 3, Bit 5, and Bit 6 are switched depending on the PDS state (servo amplifier internal state). Details are as follows: Statusword (bin) PDS state x0xx xxx0 x0xx 0000 Not ready to switch on x0xx xxx0 x1xx 0000 Switch on disabled x0xx xxx0 x01x 0001...
Page 44
• Status DO 2 Symbol Description Reference S_ZPASS Z-phase already passed After the Z-phase is passed, S_ZPASS turns on. The value at reading is undefined. S_ZSP Zero speed detection Refer to "Signal (device) explanations" in the following S_VLC Limiting speed manual.
Page 45
• Status DO 4 Symbol Description Reference The value at reading is undefined. ...
Page 46
• Status DO 6 Symbol Description Reference The value at reading is undefined. ...
Page 47
• Status DO 8 Symbol Description Reference The value at reading is undefined. ...
Page 48
(csp) or cyclic synchronous velocity mode (csv). • Related objects Index Object Name Data Access Default Description Index Type value 6060h Modes of operation MR-J5-G/MR-J5W-G User's Manual (Object Dictionary) 6061h Modes of operation display 6502h Supported drive mode 000003A0h 2 APPENDIX 2.1 CC-Link IE TSN...
Page 49
• Control switching between position/speed/torque modes Changes to the OMS Bit of [Controlword (Obj. 6040h)] are not accepted until control switching finishes. Before inputting commands, check that the control mode has been switched by referring to [Modes of operation display (Obj. 6061h)]. In addition, switch the control modes when the start command is turned off. (For example, when "Homing operation start"...
Page 50
• Control switching for continuous operation to torque control mode (ct) To switch to continuous operation to the torque control mode (ct), the switching must be performed from the cyclic synchronous position mode (csp) or cyclic synchronous velocity mode (csv). Only the "csp" and "csv" control modes switch to "ct".
Setting [Pr. PC76.1_ZSP disabled selection at control switching] to "1" (disabled (control switching is performed regardless of the range of ZSP)) enables switching of the control mode without checking for switching condition "Servo motor being stopped" on the servo amplifier. Set [Pr. PC76.1] to "1" only if switching the control mode without waiting for the servo motor to stop.
Section 1.1, Section 2.1 This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
WARRANTY Warranty 1. Warranty period and coverage We will repair any failure or defect hereinafter referred to as "failure" in our FA equipment hereinafter referred to as the "Product" arisen during warranty period at no charge due to causes for which we are responsible through the distributor from which you purchased the Product or our service provider.
TRADEMARKS MELSERVO is a trademark or registered trademark of Mitsubishi Electric Corporation in Japan and/or other countries. All other product names and company names are trademarks or registered trademarks of their respective companies. SH(NA)-030302ENG-E...
Page 56
SH(NA)-030302ENG-E(2103)MEE MODEL: MODEL CODE: HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14 , YADA-MINAMI 5-CHOME , HIGASHI-KU, NAGOYA , JAPAN When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission. Specifications are subject to change without notice.