hit counter script

Advertisement

Quick Links

OWNER'S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
TYPE : WALL MOUNTED
MODELS : ASNW096MMF0 - ASUW096MUF0 (AS-W096MMF0)
ASNW126MMF0 - ASUW126MUF0 (AS-W126MMF0)
P/NO : MFL67399704
www.lg.com

Advertisement

Table of Contents
loading

Summary of Contents for LG ASNW096MMF0

  • Page 1 OWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED MODELS : ASNW096MMF0 - ASUW096MUF0 (AS-W096MMF0) ASNW126MMF0 - ASUW126MUF0 (AS-W126MMF0) www.lg.com P/NO : MFL67399704...
  • Page 2 TIPS FOR SAVING ENERGY TIPS FOR SAVING ENERGY Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below: •...
  • Page 3: Important Safety Instructions

    SAFETY PRECAUTIONS IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE. Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product. WARNING It can result in serious injury or death when the directions are ignored. CAUTION It can result in minor injury or product damage when the directions are ignored.
  • Page 4 SAFETY PRECAUTIONS Operation • Do not let the air conditioner run for a long time when the humidity is very high or when a door or window has been left open. Failure to do so may result in product failure. •...
  • Page 5 SAFETY PRECAUTIONS CAUTION Installation • Make sure to check if there is a refrigerant leak after you install or repair the air conditioner. Failure to do so may result in product failure. • Install the drain hose properly for smooth drainage of condensed water. Failure to do so may result in product failure.
  • Page 6: Table Of Contents

    TABLE OF CONTENTS TABLE OF CONTENTS TIPS FOR SAVING ENERGY ADVANCED FUNCTIONS Changing room temperature quickly IMPORTANT SAFETY Indoor air purification INSTRUCTIONS - Auto clean operation Plasma purification operation Auto operation BEFORE USE Auto changeover operation Components °C/°F Conversion Operation ranges Energy saving cooling mode Health care Display screen brightness...
  • Page 7: Before Use

    BEFORE USE BEFORE USE Components Indoor unit Plasmaster filter Front Panel On/Off button Signal receiver Operation lamp Honeycomb Filter Air Filter Plasmaster Ionizer Air deflector Air outlet (vertical louver & Horizontal vane) * The feature can be changed according to a type of model. NOTE •...
  • Page 8: Health Care

    Common odor filter removes ordinary odors that cause migraine and chronic fatigue. LG Virus & Allergy Safe Filter blocks neu- <Plasmaster Ionizer> ramidase and hemagglutinin, which is acti- vated when the virus breaks up from host cell to proliferate.
  • Page 9: Using The Remote Control

    BEFORE USE Using the remote control You can operate the air conditioner more conveniently with the remote control. You will find the buttons for the additional functions bellow the down of the display screen. Wireless remote control Control Display Description panel screen Plasma button*:Plasmaster filter purifies...
  • Page 10: Inserting Batteries

    BEFORE USE Inserting batteries Fix the holder by fastening the 2 screws firmly with a screwdriver or using adhered Insert batteries before using the remote double-sided adhesive tape. control. The battery type used is AAA (1.5 V). Remove the battery cover. Slide the remote control into the holder.
  • Page 11: Basic Functions

    BASIC FUNCTIONS BASIC FUNCTIONS Cooling your room Removing humidity (Dehumidifying operation) (Cooling operation) Press to turn on the power. This mode removes excess moisture from an environment with high humidity or in the rainy Press repeatedly to select the cooling season, in order to prevent mold from setting operation.
  • Page 12: Airing Your Room

    BASIC FUNCTIONS Airing your room Adjusting the air flow direc- (Air Circulation operation) tion This mode only circulates the indoor air To adjust the direction of the air flow hori- zontally, press i repeatedly and select without changing the room temperature. The the desired direction.
  • Page 13: Turning On The Air Conditioner Automatically At A Set Time

    BASIC FUNCTIONS Canceling the timer setting Press to select the minutes. Press to finish. Press m. Press m or n to select the timer setting to cancel. Press Turning on the air conditioner auto- - To cancel all timer settings, press matically at a set time Press - The icon below flickers at the bottom of...
  • Page 14: Advanced Functions

    ADVANCED FUNCTIONS ADVANCED FUNCTIONS Indoor air purification The air conditioner offers some additional ad- vanced functions. Plasmaster Auto Cleaning Changing room temperature In the cooling and dehumidifying operations, moisture is generated inside the indoor unit. quickly Use the auto cleaning function to remove such moisture.
  • Page 15: Plasma Purification Operation

    In this mode, the fan speed and the tempera- Ion particles from Plasmaster Ionizer devel- ture adjust automatically, based on the room oped by LG sterilize the aerial bacteria and temperature. other harmful substances. Press to turn on the power.
  • Page 16: Auto Changeover Operation

    ADVANCED FUNCTIONS Auto Changeover operation Energy saving cooling mode This mode changes the operation mode auto- This mode minimizes power consumption dur- matically to maintain the set temperature ing cooling and increases the set temperature at ±2°C. to the optimal level for a more comfortable en- vironment.
  • Page 17: Operating The Air Conditioner Without The Remote Control

    ADVANCED FUNCTIONS Operating the air conditioner - For cooling and heating models, the oper- ation mode changes, depending on the without the remote control room temperature. You can use the On/Off button of the indoor Operation unit to operate the air conditioner when the Room temp.
  • Page 18: Restarting The Air Conditioner Automatically

    ADVANCED FUNCTIONS Restarting the air conditioner In case of turning Off automatically Close the front panel. - Lift down both sides of the panel slightly. When the air conditioner is turned on again after a power failure, this function restores the previous settings.
  • Page 19: Maintenance

    MAINTENANCE MAINTENANCE Clean the product regularly to maintain optimal performance and to prevent possible breakdown. * This may not be provided, depending on the model. Honeycomb filter Plasmaster filter Air filter * The feature can be changed according to a type of model. Item Cleaning interval Cleaning method...
  • Page 20: Cleaning The Air Filter

    MAINTENANCE Cleaning the air filter Dry the filter in direct sunlight for 2 hours. Clean the air filter once every 2 weeks or NOTE more if necessary. Turn off the power and unplug the power • The location and shape of the filters may cord.
  • Page 21: Troubleshooting

    TROUBLESHOOTING TROUBLESHOOTING Self-diagnosis function This product has a built-in self-diagnosis function. If an error occurs, the lamp of the indoor unit will blink in 2 second intervals. If this occurs, contact your local dealer or service center. Before requesting service Please check the following before you contact the service center.
  • Page 22 TROUBLESHOOTING Problem Possible causes Corrective action • Make sure that there are no curtains, • Air is not circulating- blinds or furniture blocking the front of properly. the air conditioner. • Clean the air filter once every 2 weeks. • The air filter is dirty. •...
  • Page 23 TROUBLESHOOTING Problem Possible causes Corrective action • The timer function could be oper- ated. If the timer function would op- • The air conditioner is suddenly erate, the air-conditioner can be turn turn off. off. • Check the timer setting is correct. The air-condi- •...
  • Page 25 İTHALATÇI FİRMA ÜRETİCİ FİRMA Bosch Termoteknik Isıtma ve Klima Ticaret LG Electronics Inc. A.Ş. 76, Seongsan-dong, Changwon City, Ankara Asfaltı Üzeri, Acıbadem Mah. Gyeongnam 641-713, Republic of Korea Onur Sokak No:18/A www.lg.com Koşuyolu-Kadıköy / İstanbul / TÜRKİYE Tel: (0 216) 544 11 00...

Table of Contents