PW-6000
Intelligent Controller
Installation and Configuration Guide
Part Number: PW6K1IC
July 2007
© 2007 Honeywell. All rights reserved.
800-00005
Get other manuals https://www.bkmanuals.com

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell PW-6000

  • Page 1 PW-6000 Intelligent Controller Installation and Configuration Guide Part Number: PW6K1IC July 2007 © 2007 Honeywell. All rights reserved. 800-00005 Get other manuals https://www.bkmanuals.com...
  • Page 2 Please contact your local Honeywell representative or visit us on the web at www.honeywellaccess.com for information about ordering. Feedback Honeywell appreciates your comments about this manual. Please visit us on the web at www.honeywellintegrated.com to post your comments. Get other manuals https://www.bkmanuals.com...
  • Page 3 Get other manuals https://www.bkmanuals.com...
  • Page 4: Table Of Contents

    Host Port ....................... 18 Device Information..................22 User Configuration ..................23 Restore Default Screen ................. 24 Apply Setting Screen ..................25 Log Out......................25 Appendix A ......................27 PW-6000 Installation and Configuration Guide, Document 800-00005, Revision A Get other manuals https://www.bkmanuals.com...
  • Page 5 Figure 9: PW-6000 Host Port Configuration Screen with IP Client Connection ..................... 20 Figure 10: PW-6000 Host Port Configuration with Serial RS-232 Connection 21 Figure 11: PW-6000 Web Server Device HW Info Screen ........ 22 Figure 12: PW-6000 Web Server User Info Screen ........... 23 Figure 13: PW-6000 Web Server Restore Default Screen .........
  • Page 6 Table 3 PW-6000 Technical Specifications ........... 11 Table 4 PW-6000 Status LED Combinations During Initialization ....12 Table 5 PW-6000 Status LED Combinations During Run Time ....13 PW-6000 Installation and Configuration Guide, Document 800-00005, Revision A Get other manuals https://www.bkmanuals.com...
  • Page 7 Get other manuals https://www.bkmanuals.com...
  • Page 8: Notices

    Always make certain that any required approvals are obtained in writing. DO NOT ACCEPT VERBAL APPROVALS SINCE THEY ARE NOT VALID. Honeywell Integrated Security never recommends using the PW-6000 or related products for use as a primary warning or monitoring system. Primary warning or monitoring systems should always meet the local fire and safety code requirements.
  • Page 9: Damage During Shipment

    Honeywell Integrated Security, Inc. Copyright laws of the United States protect all information in this document or in the software product itself. Any use of this product is subject to the terms and acceptance of the Honeywell Note: Integrated Security, Inc. Software Agreement. Please request a copy from Honeywell Integrated Security, Inc.
  • Page 10: Disclaimer - Product Liability; Mutual Indemnification

    If a Customer receives a claim that a Product or any component thereof has caused personal injury or damage to the property of others, Customer shall immediately notify Honeywell Integrated Security in writing of all such claims. Honeywell Integrated Security shall defend or settle such claims and shall indemnify and hold Customer harmless for any costs or damages including reasonable attorneys’...
  • Page 11: Limited Warranty

    All Products sold or licensed by Honeywell Integrated Security include a warranty registration card which must be completed and returned to Honeywell Integrated Security by or on behalf of the end user for Honeywell Integrated Security to provide warranty service, repair, credit or exchange. All warranty work shall be handled...
  • Page 12: Product Overview

    The Intelligent Controller is the heart of the PW-6000 and provides the real time processing for the connected I/O interfaces. The PW-6000 is designed to operate without the need for a PC. It can be connected to a Pro-Watch host computer using direct serial communication, dial-up modem, or TCP/IP network connection.
  • Page 13: Other

    PW-6000 Installation Product Overview 2.3 Other • An on-board real time clock maintains the date and time, taking into account leap year and accounting for global time zones and daylight savings time changes. • The database for the system configuration and card holders are stored in FLASH memory.
  • Page 14: Figure 1: Pw-6000 Connections, Leds, And Dip Switches

    PW-6000 Installation Product Overview Figure 1: PW-6000 Connections, LEDs, and DIP Switches PW-6000 Installation Guide, Document 800-00005, Revision A Get other manuals https://www.bkmanuals.com...
  • Page 15: Setting Up The Pw-6000 Hardware

    Setting Up the PW-6000 Hardware 3 Setting Up the PW-6000 Hardware The PW-6000 processor is configured with 12 jumpers and a set of 4 DIP switches. These jumpers/switches set up the port interface, end of line termination, and operating mode configuration. Refer to the tables below to set the jumpers as required.
  • Page 16: Setting The Dip Switches

    LEDs 1 and 4. The panel then reboots by itself. All data in memory is erased except the serial number, MAC address, hardware revision, and OEM code. PW-6000 Installation Guide, Document 800-00005, Revision A Get other manuals https://www.bkmanuals.com...
  • Page 17 PW-6000 Installation Setting Up the PW-6000 Hardware The PW-6000 DIP switches need to be set twice: 1. Configure the S4-S3-S2-S1 DIP switches to off-off-on-off to set the default TCP/IP address to 192.168.0.251. 2. Apply power to the panel to set the IP address.
  • Page 18: Technical Specifications

    Setting Up the PW-6000 Hardware 3.3 Technical Specifications Table 3 PW-6000 Technical Specifications Category Description WARNING: PW-6000 is manufactured for use in low-voltage, Class 2 circuits only. Primary Power 12Vdc ± 10%, 300mA maximum. 12Vdc @ 240mA (325mA with CoBox-Micro) nominal.
  • Page 19: Status Leds

    Note: terminal labeled +12V and the return is connected to the terminal labeled GND. 3.4 Status LEDs The PW-6000 uses six on-board LEDs to provide status information during its initialization sequence and normal run-time operation. Initialization Table 4 PW-6000 Status LED Combinations During Initialization...
  • Page 20: Supplying Power To The Pw-6000 Interface

    PW-6000 Installation Setting Up the PW-6000 Hardware Run TimeSupplying Power to the PW-6000 Interface Table 5 PW-6000 Status LED Combinations During Run Time Description Off-Line / On-Line and Battery Status Off-Line = 20% On, ON-Line = 80% On Double Flash means the Battery is Low...
  • Page 21: Communications Wiring

    Setting Up the PW-6000 Hardware 3.6 Communications Wiring The PW-6000 processor communicates to the host via on-board Ethernet 10Base-T/100Base-TX port or on port 1. Port 1 may be configured as RS-232, two-wire RS-485 or optional Lantronix Ethernet 10Base-T/ 100Base-TX CoBox-Micro interface. The RS-232 interface is for direct one to one connection to a host computer, or a modem.
  • Page 22: System Configuration Via Web Interface

    PW-6000 Installation System Configuration via Web Interface 4 System Configuration via Web Interface The PW-6000 comes with Access Control Device Server Manager (ACDSM). The ACDSM is a built-in web server, through which you can configure network and other system settings. Notes: •...
  • Page 23: Home Page

    System Configuration via Web Interface 4.3 Home Page The first screen after the login is the home page which displays all the available configuration links on the left navigation bar: Figure 6: PW-6000 Web Server Home Page www.honeywell.com Get other manuals https://www.bkmanuals.com...
  • Page 24: Network Settings

    Dynamic IP option because of your network policies or configuration, you must reserve an IP address at the DHCP server for the MAC (Media Access Control) address in the PW-6000 panel. The MAC address is a unique identifier attached to network adapters. Each time the PW-6000 panel requests an IP address, the DHCP server will assign the address that was reserved for it.
  • Page 25: Host Port

    Primary Host Port and Alternate Host Port: Some of the fields change dynamically depending on the Connection Type selected. Note: IP Server Connection Type Figure 8: PW-6000 Host Port Configuration Screen with IP Server Connection www.honeywell.com Get other manuals https://www.bkmanuals.com...
  • Page 26 Connection Type. Select IP Server (the standard connection type), so that the Pro-Watch Host will poll the PW-6000 panel. The panel does not currently support the IP Client option, which would cause the PW-6000 panel to poll the Pro-Watch Host and the Host to reply to the panel.
  • Page 27: Figure 9: Pw-6000 Host Port Configuration Screen With Ip Client

    PW-6000 Installation System Configuration via Web Interface IP Client Connection Type Figure 9: PW-6000 Host Port Configuration Screen with IP Client Connection The PW-6000 panel does not currently support an IP Client connection. Note: www.honeywell.com Get other manuals https://www.bkmanuals.com...
  • Page 28: Figure 10: Pw-6000 Host Port Configuration With Serial Rs-232 Connection

    System Configuration via Web Interface Serial-RS232, Serial-RS485, Serial-Modem, or Serial-CoBox Connection Types Figure 10: PW-6000 Host Port Configuration with Serial RS-232 Connection 1. From the PW6000 Communication Address drop-down list, select one of the eight (0 to 7) available communication addresses for the PW-6000 board.
  • Page 29: Device Information

    Select a Flow Control from the drop-down list. 4. Click OK. 4.6 Device Information Click the Device Info link on the navigation bar to display the read-only Access Control Device Hardware Information screen: Figure 11: PW-6000 Web Server Device HW Info Screen www.honeywell.com Get other manuals https://www.bkmanuals.com...
  • Page 30: User Configuration

    4.7 User Configuration Click the Users link on the navigation bar to display the User screen where you can add, edit, and delete user records: Figure 12: PW-6000 Web Server User Info Screen Adding a User Follow these steps: 1. Click New Account to display the new user account screen.
  • Page 31: Restore Default Screen

    Click the Restore Default link on the navigation bar to restore the default configuration values for the PW-6000: Figure 13: PW-6000 Web Server Restore Default Screen 1. Click Restore Default to reload the default factory settings for all the configuration variables.
  • Page 32: Apply Setting Screen

    Figure 14: PW-6000 Web Server Apply Setting Screen Click Apply, Reboot to apply all the configured values and reboot the PW-6000. 4.10 Log Out Click the Log Out link on the navigation bar to log out of the web server.
  • Page 33 PW-6000 Installation System Configuration via Web Interface www.honeywell.com Get other manuals https://www.bkmanuals.com...
  • Page 34: Connection

    PW-6000 Web Server and Pro-Watch Channels The PW-6000 web server’s host port configuration requires corresponding changes in the way the Pro-Watch’s channels are configured. The PW-6000 web server host ports and the Pro-Watch channel ports must have the correct values to communicate with each other.
  • Page 35 • IP Address • Port Number If you are using a modem, and the modem uses a procedure that Note: calls Pro-Watch, then the modem must be the primary port. www.honeywell.com Get other manuals https://www.bkmanuals.com...
  • Page 36 135 W. Forest Hill Avenue Oak Creek, WI 53154 414-766-1700 414-766-1798 Fax European Office Boblingerstrasse 17 Specifications subject to change D-71101 Schonaich without notice. Germany 49-7031-637-782 © Honeywell. All rights reserved. 49-7031-637-769 Fax www.honeywell.com 800-00005, Revision A Get other manuals https://www.bkmanuals.com...