hit counter script

Advertisement

Quick Links

OWNER'S MANUAL
AIR
CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
TYPE : WALL MOUNTED INVERTER
MODELS : ASNW096NRR0 - ASUW096NRR0 (AS-W096NRR0)
ASNW126NRR0 - ASUW126NRR0 (AS-W126NRR0)
P/NO : MFL68124607
www.lg.com

Advertisement

Table of Contents
loading

Summary of Contents for LG ASNW096NRR0

  • Page 1 OWNER’S MANUAL CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED INVERTER MODELS : ASNW096NRR0 - ASUW096NRR0 (AS-W096NRR0) ASNW126NRR0 - ASUW126NRR0 (AS-W126NRR0) www.lg.com P/NO : MFL68124607...
  • Page 2 TIPS FOR SAVING ENERGY TIPS FOR SAVING ENERGY Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below: •...
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE. Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product WARNING It can result in serious injury or death when the directions are ignored CAUTION It can result in minor injury or product damage when the directions are ignored WARNING...
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS Operation • Do not let the air conditioner run for a long time when the humidity is very high or when a door or window has been left open. Failure to do so may result in product failure. •...
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS CAUTION Installation • Make sure to check if there is a refrigerant leak after you install or repair the air conditioner. Failure to do so may result in product failure. • Install the drain hose properly for smooth drainage of condensed water. Failure to do so may result in product failure.
  • Page 6: Table Of Contents

    TABLE OF CONTENTS TABLE OF CONTENTS TIPS FOR SAVING ENERGY ADVANCED FUNCTIONS Changing room temperature quickly IMPORTANT SAFETY Auto indoor cleaning INSTRUCTIONS - Auto Clean operation Display the current energy usage Plasmaster Purification operation BEFORE USE Auto operation Components Auto Changeover operation Using the remote control Silent mode - Inserting batteries...
  • Page 7: Before Use

    BEFORE USE BEFORE USE Components Indoor unit Air inlet Front panel On/ Off button Display 3M filter Air filter Signal Ionizer receiver Air outlet Air deflector (Vertical louver & Horizontal vane) * The feature can be changed according to a type of model. NOTE •...
  • Page 8: Using The Remote Control

    BEFORE USE Using the remote control You can operate the air conditioner more conveniently with the remote control. Wireless remote control Control Display Description panel screen IONIZER button* : Plasmaster Ionizer sterilize the aerial bacteria and other harmful substances. Sleep mode auto button*: Sets the sleep mode auto operation.
  • Page 9: Inserting Batteries

    BEFORE USE Inserting batteries Fix the holder by fastening the 2 screws firmly with a screwdriver. Insert batteries before using the remote control. The battery type used is AAA (1.5 V) Remove the battery cover. Slide the remote control into the holder. Insert the new batteries and make sure that the + and - terminals of the batteries are installed correctly.
  • Page 10: Basic Functions

    BASIC FUNCTIONS BASIC FUNCTIONS Cooling your room Removing humidity (Cooling operation) (Dehumidifying operation) Press to turn on the power. This mode removes excess moisture from an environment with high humidity or in the rainy Press repeatedly to select the cooling season, in order to prevent mold from setting operation.
  • Page 11: Airing Your Room

    BASIC FUNCTIONS Airing your room Adjusting the air flow direc- (Air Circulation operation) tion This mode only circulates the indoor air To adjust the direction of the air flow hori- without changing the room temperature. zontally(vertically), press ) repeat- edly and select the desired direction. Press to turn on the power.
  • Page 12: Turning On The Air Conditioner Automatically At A Set Time

    BASIC FUNCTIONS Turning on the air conditioner auto- Setting sleep mode matically at a set time Use the sleep mode to turn off the air condi- tioner automatically when you go to sleep. Press Press to turn on the power. - The icon below flickers at the bottom of Press the display screen.
  • Page 13: Advanced Functions

    ADVANCED FUNCTIONS ADVANCED FUNCTIONS Auto indoor cleaning The air conditioner offers some additional ad- vanced functions. Auto Clean operation Changing room temperature In the cooling and dehumidifying operations, moisture is generated inside the indoor unit. quickly Use the auto cleaning function to remove such moisture.
  • Page 14: Plasmaster Purification Operation

    ADVANCED FUNCTIONS Plasmaster Purification operation Code Description Ion particles from Plasmaster Ionizer devel- Cool oped by LG sterilize the aerial bacteria and other harmful substances. Cool slightly Maintain Press to turn on the power. room Press temperature is displayed on the display screen.
  • Page 15: Silent Mode

    ADVANCED FUNCTIONS Silent mode Press to turn the power on. Press It is to prevent potential claims by neighbors, is displayed on the display screen. reducing noise from outdoor units. The outdoor unit sound pressure in cooling and heating mode is decreased by 3dB com- pared to the rated sound pressure Press to turn the power on.
  • Page 16: Operating The Air Conditioner Without The Remote Control

    ADVANCED FUNCTIONS Operating the air conditioner In case of turning Off without the remote control Open the front panel. - Lift up both sides of the panel slightly. You can use the On/Off button of the indoor unit to operate the air conditioner when the Press the On/Off button.
  • Page 17: Restarting The Air Conditioner

    ADVANCED FUNCTIONS Restarting air conditioner au- tomatically When the air conditioner is turned on again after a power failure, this function restores the previ- ous settings. This function is a factory default set- ting. Disabling auto restart Open the front panel. - Lift up both sides of the panel slightly.
  • Page 18: Maintenance

    MAINTENANCE MAINTENANCE If the air conditioner will not be used for an extended of time, dry the air conditioner to maintain it in best condition. Dry the air conditioner in Fan mode for 3 to 4 hours and disconnect the power plug. There may be internal damage if moisture is left in components.
  • Page 19 MAINTENANCE Cleaning the Ionizer • Turn off the power and unplug the power cord. • Use dry cotton bud to remove any dust. Note : The Ionizer may not be included in some models. CAUTION • Turn off the power and unplug the power cord before you perform any maintenance; other- wise it may cause electric shock.
  • Page 20: Cleaning The Air Filter

    • If not sounding clicking at both sides, push both sides of the front panel. • We suggest changing the 3M filter every 6 months. • If you need more filters, please contact the LG service center (Refer to the war- ranty card)
  • Page 21: Troubleshooting

    TROUBLESHOOTING TROUBLESHOOTING Self-diagnosis function This product has a built-in self-diagnosis function. If an error occurs, the lamp of the indoor unit will blink in 2 second intervals. If this occurs, contact your local dealer or service center. Before requesting service Please check the following before you contact the service center.
  • Page 22 TROUBLESHOOTING Problem Possible causes Corrective action • Make sure that there are no curtains, • Air is not blinds or furniture blocking the front of circulatingproperly. the air conditioner. • Clean the air filter once every 2 weeks. • The air filter is dirty. •...
  • Page 23 TROUBLESHOOTING Problem Possible causes Corrective action • The timer function could be operated. If the timer function • The air conditioner is suddenly would operate, the air-conditioner turn off. can be turn off. • Check the timer setting is correct. air-conditioner •...
  • Page 25 İTHALATÇI FİRMA ÜRETİCİ FİRMA Bosch Termoteknik Isıtma ve Klima Sanayi LG Electronics Inc. Ticaret A.Ş. 76, Seongsan-Gu Changwon City Gyeong Nam Merkez Adresi : Organize Sanayi Bölgesi İkinci 642-713 R.O.K, South Korea Kısım Gaziler Caddesi No.2 45030 Manisa İrtibat Adresi : Ankara Asfaltı Üzeri, Acıbadem Mah.