1.12/2.25 gb - 1.0" high 4.51 gb - 1.6" high 3.5 form factor disk drive version 5.0 (88 pages)
Summary of Contents for IBM FlashSystem 720
Page 1
IBM FlashSystem Installing the IBM FlashSystem 720 GI11-9895-03...
Page 3
IBM FlashSystem Installing the IBM FlashSystem 720 GI11-9895-03...
Page 4
Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 15, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. This edition applies to IBM FlashSystem and to all subsequent releases and modifications until otherwise indicated in new editions.
Safety notices ... . v Connecting to the web management interface . Acquiring the system IP address. Accessing the web interface . Installing the IBM FlashSystem 720 . . . 1 Configuring the controllers . . 10 Unpacking the system .
Page 6
IBM FlashSystem: Installing the IBM FlashSystem 720...
You should also refer to the safety information documentation any time you do not clearly understand any safety information in the U.S. English publications. Replacement or additional copies of safety information documentation can be obtained by calling the IBM Hotline at 1-800-300-8751.
Page 8
Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v Connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
Page 9
Observe the following precautions when working on or around your IT rack system: v Heavy equipment–personal injury or equipment damage might result if mishandled. v Always lower the leveling pads on the rack cabinet. v Always install stabilizer brackets on the rack cabinet. v To avoid hazardous conditions due to uneven mechanical loading, always install the heaviest devices in the bottom of the rack cabinet.
Page 10
Pack the rack cabinet in the original packaging material, or equivalent. Also lower the leveling pads to raise the casters off of the pallet and bolt the rack cabinet to the pallet. (R002) (L001) (L002) viii IBM FlashSystem: Installing the IBM FlashSystem 720...
Page 11
(L003) All lasers are certified in the U.S. to conform to the requirements of DHHS 21 CFR Subchapter J for class 1 laser products. Outside the U.S., they are certified to be in compliance with IEC 60825 as a class 1 laser product.
Page 12
Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call. (C003)
Installing the IBM FlashSystem 720 ™ Learn about initial setup and configuration of your IBM FlashSystem 720. Unpacking the system Your system is supplied with a packing list. Ensure that you received all of the components listed. 1. Examine the external chassis for any damage that might have occurred during shipping.
(R001) Determining the location This procedure assumes that you have installed the rack, and now you must install the system into the rack. IBM FlashSystem: Installing the IBM FlashSystem 720...
Do not install mismatched hardware by using washers or spacers. If you do not have the correct rails and fittings for your rack, contact your IBM reseller. Procedure 1.
MCP failover occurs, these logs will not be available to assist in troubleshooting. Connecting power to the system A fully configured IBM FlashSystem 720 requires approximately 400 watts of power. Note: Although the system will operate when only one power supply is connected, this method is not recommended.
Page 17
When ac power is connected, the storage system powers up and the front panel display shows the power-on sequence. When the system is fully ready, the front panel displays Status: OK and the system performance statistics, including the system bandwidth and total input/output operations per second. Installing the IBM FlashSystem 720...
Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v Connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
Displays the current IP configuration, host name, IP Config address, subnet mask, gateway address (if applicable), and hardware MAC address for the management controller port. Eth0 Config Configures the Eth0 Ethernet MCP. Eth1 Config Configures the Eth1 Ethernet MCP. Installing the IBM FlashSystem 720...
DNS server. To enter your network's DNS server information, you can use the web management interface. The DNS settings are configured using the Network node in the system tree. IBM FlashSystem: Installing the IBM FlashSystem 720...
2. Use the ↓ button to scroll until you see the Eth0 P line and the lines below it. 3. Take note of the IP address. Accessing the web interface Learn to how to access the storage system web interface. About this task To open the web interface, complete the following steps: Installing the IBM FlashSystem 720...
Configuring access policies for the LUNs Learn how to configure access policies for the logical unit numbers (LUNs). About this task To add an access policy to a new LUN, complete the following steps: IBM FlashSystem: Installing the IBM FlashSystem 720...
IBM Service Center cannot contact the storage system by using call home. When certain events occur in the system, call home sends a notification to the IBM Service Center. After you receive the notification, IBM service personnel analyze the problem promptly and take appropriate action.
System to the IBM support team closest to your geographical location. About this task The contact information is also used by IBM representatives to notify you when a system requires service. To update the support contact information, complete the following steps:...
4. Add a contact name, email address, and phone number. Verifying and updating the firmware and software After the initial configuration of the system is complete, IBM strongly recommends that you confirm whether a later level of firmware and software is available. and update to that level.
Page 26
# is the slot number of the new flashcard. 8. Enter q to exit diagnostic mode and return to the command prompt. 9. Enter #storage to confirm that all the flashcards are formatted. IBM FlashSystem: Installing the IBM FlashSystem 720...
IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the web at Copyright and trademark information at www.ibm.com/legal/copytrade.shtml.
Page 29
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
Page 30
Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user will be required to take adequate measures. IBM Taiwan Contact Information: IBM FlashSystem: Installing the IBM FlashSystem 720...
Page 31
Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
Consult an IBM-authorized dealer or service representative for help. Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for IBM FlashSystem: Installing the IBM FlashSystem 720...
Page 33
This product is in conformity with the protection requirements of EU Council Directive 2004/108/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility. IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product, including the fitting of non-IBM option cards.
Page 34
Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
Permissions for the use of these publications are granted subject to the following terms and conditions. Applicability: These terms and conditions are in addition to any terms of use for the IBM website. Personal Use: You may reproduce these publications for your personal, noncommercial use provided that all proprietary notices are preserved.
Page 36
IBM FlashSystem: Installing the IBM FlashSystem 720...
Page 38
Part Number: 00DH782 Printed in USA GI11-9895-03...