Summary of Contents for Siemens SIMATIC IPC BX-32A
Page 1
07102005SIMATIC IPC BX-32A Preface Product description SIMATIC Safety instructions Installing and connecting the device Industrial PC SIMATIC IPC BX-32A Commissioning the device Operating the device Operating Instructions Expanding and assigning parameters to the device Device maintenance and repair Technical specifications...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
General knowledge in the field automation control engineering is recommended. Scope of the operating instructions These operating instructions are valid for all order variants of the SIMATIC IPC BX-32A. History The following editions of these operating instructions have already been published:...
Page 4
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply latest updates may increase customers' exposure to cyber threats.
• Boot modes Windows® operating Information on: • Online at: system • Commissioning the operating Microsoft® Windows® 10 system (https://support.industry.siemens. • Restoring the operating system com/cs/ww/en/view/109749498) • Configuration of the operating system SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 10
SIMATIC IPC Creating a bootable • Creating a bootable USB flash drive USB flash drive drive for recovery of operating (https://support.industry.siemens. system, software and drivers com/cs/ww/en/view/109811224) See also SIMATIC IPC DiagBase (https://support.industry.siemens.com/cs/ww/en/view/109749690) SIMATIC IPC DiagMonitor (https://support.industry.siemens.com/cs/ww/en/view/39129913) SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Product description 1.2 Product highlights Product highlights The SIMATIC IPC BX-32A with innovative Intel processor architecture is a cost-optimized industrial box PC that complements the embedded series. It is a cost- and function-reduced alternative to SIMATIC IPC BX-39A. Device view...
The SIMATIC IPC has CE certification for use in the industrial sector as well as in residential and commercial areas and small businesses. In addition to the industrial applications, therefore, it can also be used in building automation or in public facilities. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Status Meaning of the status LED 1 10 Mbps Lit green 100 Mbps Lit orange 1000 Mbps LED 2 No connection Lit orange Connection exists Flashes orange Activity See also Technical support (https://support.industry.siemens.com) SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Power supply 9-36 V DC ② Slot for memory module ③ Motherboard ④ Backup battery ⑤ Slot for M.2 expansion module ⑥ Slot for drive (SSD) under the heat sink ⑦ Heat sink for drive (SSD) SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Accessories and spare parts 1.6.1 Hardware accessories Accessories from Siemens are available for your device that are not included in the scope of delivery. Obtaining accessories from the SIEMENS Industry Mall 1. On the Internet, go to Industry Mall (https://mall.industry.siemens.com).
• For control cabinet mounting: Use a central, easily accessible AC circuit breaker close to the device, if possible. • When you install the device, make sure that the power supply connector is easily accessible. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 18
Validate the correct functioning of the plant to avoid functional restrictions. Use in industrial environments Note Use in an industrial environment without additional protective measures This device was designed for use in a normal industrial environment according to IEC 60721-3-3. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 19
The device contains electronic components which may be destroyed by electrostatic charge. This can result in malfunctions and damage to the machine or plant. Take corresponding precautionary measures before you open the device. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
• Do not expose the device to direct heat radiation from a heating device. • If condensation develops, wait approximately 12 hours or until the device is completely dry before switching it on. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
When you plan your project, you should make allowances for: • The climatic and mechanical environmental conditions specified in the operating instructions. • Do not operate the device in severe operating conditions which are subject to caustic vapors or gases. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 22
• Switch off radiating devices. • Reduce the radio output of radiating devices. • Read the information on electromagnetic compatibility. • Read the information in the technical specifications. See also Ambient conditions (Page 72) SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
• The IPC in question must be turned off and the power supply connector must be plugged • During the measurement, all cables from the plant to the IPC should be connected. • All other components in the plant must be active. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
• UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". • We are not liable for functional limitations caused by the use of third-party devices or components. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
You will find the latest information on additional software for your device under: Accessories and spare parts (Page 16) Printed documents • Quick Install Guide SIMATIC IPC BX-32A • Product Information "Important notes on your device" SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
If the contents of the package are incomplete, damaged or do not correspond to your order, you can use the After Sales Information System (ASIS) (http://siemens.com/asis) to provide feedback on product deliveries and repairs. Complete the online form for product delivery (quality control notification) under the heading "Product delivery: Feedback on quality control and repairs".
The following illustrations are examples. The data of your device may differ from the data in these examples. Nameplate The following image shows the nameplate on the SIMATIC IPC BX-32A as an example. COA label The COA label (Certificate of Authenticity) is located on the rear of the device.
• Above at least 50 mm • At least 50 mm at the side Note Observe the permitted temperature range for operation of the device in the respective mounting position as defined in section "Technical specifications (Page 68)". SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 29
The interfaces are at the bottom. Vertical mounting position The vertical installation position is permissible for vertical mounting: Vertical mounting The interfaces are at the front. The con- nection for the power supply is located at the bottom. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
The device may not be securely fitted if you use anchors and screws other than those specified below for mounting. The device can fall and may be damaged. • Use only the specified anchors and screws. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 31
8 mm, 40 mm deep • Dowel, ∅ 8 mm, 40 mm length • Screw, ∅ 5 mm, 40 mm length Plasterboard, 14 mm Toggle bolt, ∅ 4 mm, 50 mm length min. 13 mm thickness SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
(as specified in order number). Requirements • 1 DIN rail clip • 4 screws • 1 T20 screwdriver Procedure 1. Secure the DIN rail bracket with four screws with a tightening torque of 2.5 Nm. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
You will hear the device click into place. Removal 1. Push down the device until it is released by the rail clips. 2. Swing the device out of the DIN rail. 3. Lift the device up and off. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
(as specified in order number). Requirements • 2 wall mounting brackets • 6 screws • 1 T20 screwdriver Procedure 1. Secure the wall mounting brackets with three screws each and a tightening torque of 2.5 Nm. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
(as specified in order number). Requirements • 2 vertical mounting brackets • 6 screws • 1 T20 screwdriver Procedure 1. Secure the portrait mounting brackets with three screws each and a tightening torque of 2.5 Nm. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
2. Screw the cable lug onto the protective conductor connection as shown. 3. Wire the protective conductor to the protective conductor connection of the control cabi- net in which the device is installed. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Utilisez des câbles en cuivre (Cu) pour tous les câbles d'alimentation qui sont raccordés à l'appareil par des bornes, par exemple les câbles d'alimentation 24 V CC sur le connecteur d'alimentation 24 V CC. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 38
Installing and connecting the device 3.3 Connecting the device 1. Connect the cables as shown with a tightening torque of 0.6 Nm. Make sure the connection terminal is in the correct position as shown. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
The 9-36 V DC power supply is protected against polarity reversal. If you mix up the 9-36 V DC connecting cables and ground, the device is not damaged but does not switch on. After the power supply has been connected correctly, the device will again be ready to operate. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
1. Connect the I/O devices to the respective interfaces. Information on the position of the interfaces is available in "Interfaces and operating elements (Page 13)". 2. Secure the cables with the strain relief. See: Securing the lines (Page 44) SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 41
The following table shows the various connection options for the monitors on the device interfaces. Motherboard DPP1 DPP2 Monitor 1 Monitor 2 1) - via DP to DVI-D adapter 2) - via DP-VGA adapter SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
• Observe the max. permissible power consumption values for the device. Requirements • The device is switched off. Procedure The procedure is described based on the example of a USB expansion card. 1. Connect the cable to the marked slot. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Control level. You can find information on this under SIMATIC NET (http://w3.siemens.com/mcms/automation/en/industrial- communications/Pages/Default.aspx). The software package and the documentation are not included in the scope of delivery. Additional information You can find additional information on the Internet at: Technical Support (https://support.industry.siemens.com). SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
2. Pass the cable tie around the strain relief bar and secure the cables as shown. 3. Cut off the protruding ends of the cable ties. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
You can find information on first startup of the device and commissioning the installed Windows® operating system in the operating system documentation. See also "Important instructions and manuals for operating the device (Page 9)" for more on this. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Perform a hardware reset only in the case of an emergency. • Operate the on/off switch to initiate a hardware reset, see "Interfaces and operating elements (Page 13)". See also General safety instructions (Page 17) SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
A USB keyboard and mouse and a monitor can be connected later for diagnostics. A digital DVI monitor or DisplayPort monitor is only activated retrospectively when the Windows operating system has booted completed. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Take corresponding precautionary measures before you open the device. Requirements • The device is fully disconnected from the line voltage, see "Switching off the device (Page 46)". • All connecting cables are unplugged. • Screwdriver of type Torx T10 SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 49
6.1 Opening the Device Procedure 1. Remove the marked screws. 2. Swivel the front panel away to the rear, as shown in the image. 3. Put down the front panel. Close the device in reverse order. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Take corresponding precautionary measures before you open the device. Requirements • The device is fully disconnected from the line voltage, see "Switching off the device (Page 46)". • All connecting cables are unplugged. • Screwdriver of type Torx T10 SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 51
6.2 Open device with expansion slots Procedure 1. Remove the marked screws. 2. Slide the front panel forwards in the di- rection of the arrow. 3. Put down the front panel. Close the device in reverse order. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
• You can find information on the type of expansion card you can install in specific slots under "Expansion card slots on the bus board (Page 89)". SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 53
2. Remove the retainer (2). 3. Insert the expansion card into the slot on the bus board (3). Secure the expansion card with the corre- sponding screw. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 54
Proceed in reverse order of installation. Configuring BIOS setup You may need to make settings in the BIOS Setup. For detailed information about installation, please refer to the documentation provided with the specific expansion card. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
• The connecting cable between M.2 modules and conditioner card should be at least 150 mm long. See also Position of the interfaces on the motherboard (Page 87) Dimension drawing of expansion modules (M.2) (Page 80) SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Torx T8. Insert the M.2 module into the relevant slot (X100). Take care not to touch the contacts of the M.2 module when you do this. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 57
You may need to make settings in the BIOS Setup. For detailed information about installation, please refer to the documentation provided with the specific expansion module. See also Replacing M.2 NVMe SSD (Page 60) SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
• Memory transaction rate 3200 MT/sec "unbuffered" • "without ECC" Note Use only the memory modules recommended by Siemens AG. Requirement • The device is open, see important information regarding this under "Opening the Device (Page 48)" or "Open device with expansion slots (Page 50)".
Page 59
After insertion and removal Close the device. The new memory capacity will be automatically detected and displayed in the BIOS setup when the device is switched on. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
• M.2 NVMe SSDs with a length of 30 or 80 mm • The device is fully disconnected from the line voltage, see "Switching off the device (Page 46)". • Screwdrivers of type Torx T10 and T8 SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 61
Torx T8. 4. Pull the M.2 NVMe SSD out of the slot. Procedure - Installation Follow the steps for removal in reverse order. See also Hardware accessories (Page 16) SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Replacement interval Backup battery 5 years Depending on the type of use The interval for replacement of the flash drives (SSD) depends greatly on the type of use. A specific interval cannot be given. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
100 °C and protect the battery from direct sunlight, moisture and condensation. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 64
– Courant de charge anormal max. : 5 mA • Pour toute demande concernant la maintenance du produit, contactez le support technique (Page 96) Siemens. • Ne jetez pas au feu des piles au lithium, n'effectuez pas de soudage sur la pile, ne la rechargez pas, ne l'ouvrez pas, ne la court-circuitez pas, n'intervertissez pas les pôles, ne...
Page 65
1. Remove the battery from socket as shown. 2. Place the new battery below the two con- tacts (1) and press it into the base (2) while applying slight pressure. 3. Close the device. 4. Check the firmware/BIOS settings. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Installing operating system, software and drivers You can restore the factory settings of the target system (i.e. the volume partitions, the operating system with installed device drivers, and the SIEMENS software products). This allows you to restore your device quickly if it has suffered damage.
Contact a certified disposal service company for electronic scrap for environmentally sound recycling and disposal of your old device, and dispose of it according to the relevant regulations in your country. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
78 W (at 24 V) 76 W (at 36 V) Noise emission < 40 dB(A) according to DIN 45635-1 Degree of protection IP 20 to IEC 60529 Quality assurance In accordance with ISO 9001 SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 69
• IEC 61010-2-201 • EN 61010-2-201 • DIN EN 61010-2-201 • UL 61010-2-201 • CSA C22.2 No 61010-2-201 not evaluated by UL See also Connecting the 9-36 V C power supply (Page 39) SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Device with BIOS setting "Power & 2.88 A 34.56 W 1.40 A 33.60 W Performance Scenario" = "Balanced" Device with BIOS setting "Power & 3.25 A 39.00 W 1.60 A 38.40 W Performance Scenario" = "Max Per- formance" SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
This information applies to the setting "Balanced" in the BIOS Setup, menu "Advanced" > "Power&Performance" > "CPU Power Management Control" > "Power & Performance Scenario"; the maximum ambient temperature must be reduced by 5 °C for the setting "Max Performance". SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
No teaming with AMT. When using AMT, the interface X1 P1 must be used for connection to remote maintenance. Only possible with ports X1 P1 and X2 P1 SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
The following table lists the partitioning for disks ≥ 200 GB in GPT mode: Partition Name Size File system First Boot 260 MB FAT32 Second 128 MB None Third System 160 GB NTFS Fourth WinRE 500 MB NTFS Fifth Data Remainder NTFS SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
• 2011/65/EU "Restriction of the use of certain hazardous substances in electrical and electronic equipment" (RoHS Directive) EU Declaration of Conformity The associated declaration of conformity is available on the Internet at the following address: Certificate Box PC (http://support.automation.siemens.com/WW/view/en/10805671/134200). SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
DIN ISO 9001 certificate and software license agreements ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001. This has been certified by DQS (the German society for the certification of quality management systems).
10.6 Canada CANADA Canadian Notice This Class A digital apparatus complies with Canadian ICES-003. Avis Canadien Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Ca- nada. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
This product meets the requirements of Korean certification. This product satisfies the requirement of the Korean Certification (KC Mark). 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Slot for expansion modules (M.2) ④ Backup battery ⑤ Slot for the bus board Technical features of the motherboard Technical features of the motherboard can be found under "Technical specifications of the motherboard (Page 73)". SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
5 V voltage Output Ground + 3.3 V 3.3 V voltage Output max. permitted current: 1 A; with this power requirement, the total power requirement of the PCI slots must not be exceeded. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
The status of the user LEDs L1/L2/L3 can be read and written as follows. Note: Always use read-modify-write operations so that reserved bits are not overwritten. This can lead to impairment of the functionality of the device. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 92
LED L3 / Maint dark (default) LED L3 / Maint lit red LED L3 / Maint lights up green LED L3 / Maint lit yellow Reserved WDT system reset: On WDT system reset: Off SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Meaning of the bits Reserved Reserved Reserved CMOS battery capacity is still sufficient CMOS battery capacity is exhausted (remain- ing capacity is sufficient for approx. one month) CMOS battery is empty or missing Reserved Reserved Reserved SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
This step resets the "PC ON/WD" LED from pulsing red to its normal state (lit green). The WDT starts counting down. To prevent this behavior, stop the WDT before resetting the status to "Active". SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 95
WDT counter register (read/write, address 286h) Bits Meaning of the bits 00h-FFh Countdown time WDT status register (read/write, address 287h) Bits Meaning of the bits Reserved Reserved Reserved Reserved WDT status: Active WDT status: Expired Reserved Reserved Reserved SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
You can find additional information and support for the products described on the Internet at the following addresses: • Technical support (https://support.industry.siemens.com) • Support request form (https://www.siemens.com/supportrequest) • After-sales information system for SIMATIC PC / PG (https://www.siemens.com/asis) • SIMATIC Documentation Collection (https://www.siemens.com/simatic-tech-doku-portal) • Your local representative (https://www.automation.siemens.com/aspa_app) • Training center (https://siemens.com/sitrain) •...
If you use an adapter or expansion for the mouse cable, also check these connectors. If the cursor still does not appear on the screen after you have performed these checks and actions, con- tact your technical support team. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
"Boot > EFI": firmware/BIOS The boot data carrier is set up with Enable UEFI mode in the firmware/BIOS. GPT and UEFI boot is deactivated in the firmware/BIOS SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
• Signal frequencies or signal pansion card was the cause of the fault. Replace this with a levels are not adhered to Siemens expansion card or contact the supplier of the expan- • Different pin assignment sion card. If the device still crashes, contact your technical support team.
Disconnect the power plug before Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- On/off switch, without electrical isola- tion tion SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
EFUP (Environment Friendly Use Peri- Approved for Korea od) marking for China Test mark of the Underwriters Labora- UKCA marking for Great Britain tories Approval for India Disposal information, observe the local regulations. Approval for Taiwan SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port USB 3.1 SuperSpeedPlus interface SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Digital display interface with digital and VGA signals Error checking and correction Error correction code Extensible Firmware Interface Electrostatic-sensitive components European standard Ground Chassis ground Hard Disk Drive Hard disk drive Height unit SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...
Page 104
US organization for tests and certifications accord- ing to own or binational standards (with CSA / Canada) standards. Universal Serial Bus Video Graphics Array Video adapter which meets industrial standard Watchdog Program monitoring with error detection and alarming. SIMATIC IPC BX-32A Operating Instructions, 09/2023, A5E52798407-AB...