Summary of Contents for Siemens SIMATIC IPC RW-545A
Page 1
Workstation SIMATIC IPC RW-545A Preface Product description SIMATIC Safety instructions Unpacking and installing the device Industrial PC Workstation SIMATIC IPC RW-545A Connecting the device Commissioning the device Operating Instructions Operating the device Expanding and assigning parameters to the device Device maintenance and...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
• Service and maintenance of industrial PCs General knowledge in the field automation control engineering is recommended. Range of validity of these operating instructions These operating instructions are valid for all order versions of the SIMATIC IPC RW-545A. History Currently released versions of these operating instructions:...
Page 4
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
Safety instructions on transport and storage............... 40 Safety instructions for assembly ..................42 Safety instructions on ambient and environmental conditions ..........44 Safety instructions for I/O devices ..................46 Safety instructions on device and system extensions ............47 Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 6
Setting up the onboard RAID system in the firmware (Create Volume) ........ 79 6.4.3.2 Monitoring the onboard RAID system with "Intel® Optane™ Memory and Storage Management" ........................81 6.4.3.3 Integrating a new drive into an onboard RAID system ............82 Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 7
Install the internal drive on the side panel of the device ............ 121 7.6.5 Install M.2 NVMe SSD....................... 123 Device maintenance and repair ......................125 Safety instructions for repairs ................... 125 Maintenance intervals ...................... 125 Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 8
Technical specifications of the plug connectors for the power supply of graphics cards ..157 9.10 Technical specifications of the telescopic rails ..............157 9.11 Technical specifications of the operating systems ............. 158 Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 9
Troubleshooting ......................176 B.2.1 Problems with device functions ..................176 B.2.2 Problems when booting the device .................. 177 B.2.3 Problems with RAID systems .................... 178 B.2.4 Problems when using expansion cards ................178 Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 10
Markings and symbols ........................181 Overview ......................... 181 Symbols for safe use and disposal ..................181 Symbols for operator controls ..................181 Symbols of certificates and approvals ................182 Interface icons ......................... 183 Index ..............................185 Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
• Supplied in printed form with the device • Link and QR code to the online form for the quality control notification in the SIEMENS After Sales Information System (ASIS) • Operating Instructions of the device • Installation of the device •...
(http://w3.siemens.com/mcms/au tomation/en/industrielle- kommunikation/Seiten/Default.as Product highlights The SIMATIC IPC RW-545A is a high-performance industrial PC as workstation in 19" rack format (4 U). It is perfectly suited for high-performance industrial PC applications. Device view Note Depending on the configuration ordered the features and illustrations described in this manual may differ from the features of your device.
Page 13
RAID configurations and unique numbering • Status display (front LEDs) for Ethernet; alarm display for fan, temperature, watchdog and drives in RAID configurations • Remote control and remote maintenance through iAMT (Intel® Active Management Technology) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 14
• Can be used in different positions with telescopic rails or as an industrial tower PC (tower kit optional) • Pre-installed and activated operating systems: – Windows 10 IoT Enterprise 2021 LTSC (64-bit) • Fast restoration of the delivery state by restoring from USB stick Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
1.3 Scope of application Scope of application The SIMATIC IPC RW-545A offers system integrators, electrical panel builders, plant builders and machine builders a 19" rack PC platform for high-performance applications and IT applications on the control and cell level for: •...
You can install drives in removable trays, in which the drives are easily accessible from the outside without opening the device. The removable trays can be locked, thus protecting the drives from unauthorized access. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 17
Components of the removable tray Status display (Page 30) Status display (Page 30) Number of the mounting location (here: Mounting location 0) Lock See also Installation options for drives with drive cage type A (Page 104) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
3.5" drive in the assembly kit • 5.25" drive or 5.25" component Cover (if no drive is installed) or drive cover Cover See also Installation options for drives with drive cage type B (Page 114) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
• "Connection of power supply unit 550 W (Page 22)" • "Connection of power supply unit 850 W (Page 23)" • "Connection of power supply unit 700 W (2 modules, each 700 W, redundant) (Page 23)") Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
SuperSpeed backwards compatible to USB 3.0 / 2.0 / 1.1; each 900 mA / high current Sum of the currents on the USB interfaces of the device (including the internal USB interfaces) ≤ 3 A Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
USB 3.0 / 2.0 / 1.1; each 1500 mA / high current • (X63) ⑩ USB 3.2 Gen2 Type A (10 Gbps) Backwards compatible to USB 3.0 / 2.0 / 1.1; each 900 mA / high current • (X60) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
"Connecting several monitors (multi-monitoring) (Page 63)". You can find information on the graphics cards under "Technical specifications of graphic (Page 152)". 1.4.4.3 Connection of power supply unit 550 W Socket for power plug Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
1.4 External design of the device 1.4.4.4 Connection of power supply unit 850 W Socket for power plug 1.4.4.5 Connection of power supply unit 700 W (2 modules, each 700 W, redundant) Sockets for power plug Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Reset button ② The reset button is for the emergency when the device can no longer be operated. You can find information on the hardware reset under "Switching off the device (Page 74)" Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Risk of electric shock The on-off switch does not fully disconnect the device from the line voltage. You also need to observe the notes and information under "Switching off the device (Page 74)". On-off switch Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
The redundant power supply unit 700 W does not have an on-off switch. To completely disconnect the device from the mains voltage, follow the instructions under "Switching off the device (Page 74)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Data traffic ⑥ WATCHDOG Watchdog status Not activated (function GREEN Activated currently not Expired available) ⑦ TEMP Temperature status No error Possible causes: • CPU temperature is critical • Device temperature is critical Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 28
Memory and Storage You can find information under "RAID1 Management" software system (Page 78)" differs from this numbering. See important note under "Display of a defective drive of an onboard RAID system (Page 78)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
• Data transfer active GREEN (Blinking then steady) • Ready to wake up from S5 mode LED 2 Data transmission rate • 10/100 Mbps ORANGE • 1000 Mbps GREEN • 2500 Mbps Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Device is switched on and a drive is installed ② Activity Status of the drive ORANGE • Drive is active • Drive is not active See also Drive cage type A (Page 16) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Drive cage (here in the example: Drive cage type A or type B) ⑥ Guide rail for long expansion cards ⑦ Motherboard ⑧ Expansion card slots ⑨ Slot brackets (numbering of the slots for expansion cards on the enclosure) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Accessories and replacement parts 1.6.1 Hardware accessories Accessories from Siemens are available for your device. These are not included in the scope of delivery. Obtaining accessories from the SIEMENS Industry Mall You can find additional information in the online ordering system Industry Mall (https://mall.industry.siemens.com).
Page 33
DP adapter 3 adapters 6ES7648-3AJ00-1XA0* Mini DisplayPort to DisplayPort Available as single-pack or 3- pack* * Included in scope of delivery of NVIDIA T400 and NVIDIA RTX A2000 graphics cards. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 34
5.25" mounting frame for 5.25" mounting frame for removable tray. A5E35804114 HDD / SSD removable tray You can use a 2.5 "or a 3.5" drive in the removable tray. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
• Catalog and ordering system for Automation and Drives: Industry Mall (https://mall.industry.siemens.com). First select your region here and then navigate to the desired topic area. • Industrial automation technology portfolio: Products & Services (https://www.siemens.com/global/en/products/automation/pc-based.html) Area: "SIMATIC IPC software and accessories". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Touching these areas or components can cause death or serious physical injury. • Disconnect the control cabinet from the power supply before opening it. • Ensure that the power to the control cabinet cannot be turned on accidentally. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 38
"Switching off the device (Page 74)". • Do not touch power cables and data transmission cables during a thunderstorm. • Keep sufficient distance from electric cables, distributors, systems, etc. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 39
• Do not short-circuit the battery. • Do not reverse the polarity of the battery. • Do not heat the battery over 100 °C. • Protect the battery from direct sunlight, moisture and condensation. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Risk of physical injury The device is heavy and may injure persons and be damaged if it falls. • Use the handles on the front panel of the device to carry and lift the device. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 41
• Do not expose the device to direct heat radiation from a heating device. • If condensation develops, wait approximately 12 hours or until the device is completely dry before switching it on. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
There is a risk of overheating and personal injury. Note the following instructions and information under: • "Climatic and mechanical environmental conditions (Page 148)" • "Safety instructions on ambient and environmental conditions (Page 44)" Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 43
Touching these areas or components can cause death or serious physical injury. • Disconnect the control cabinet from the power supply before opening it. • Ensure that the power to the control cabinet cannot be turned on accidentally. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
• When the device is operated in severe environments which are subject to caustic vapors or gases, ensure sufficient clean air is provided. • Clean the enclosure surface with a damp cloth. • Make sure that no water gets inside the device. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 45
• Remove radiation sources from the environment of the device. • Switch off radiating devices. • Reduce the radio output of radiating devices. • Read the information on electromagnetic compatibility. • Read the information in the technical specifications. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
• Switch off the affected device and then insert the power plug. • Connect all cables from the system to the device and switch all components of the system to active before starting the measurement. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Contact your technical support team (Page 175) or the point of sale to find out which device and system expansions are suitable for installation. • Note the Information on electromagnetic compatibility (Page 165). Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 48
If you install or exchange system expansions and damage your device, the warranty becomes void. It is therefore essential that you observe the information under "Open the device (Page 93)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 49
• UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". • We are not liable for functional limitations caused by the use of third-party devices or components. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 50
Safety instructions 2.6 Safety instructions on device and system extensions Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
You can find information on ordered Microsoft® Windows® operating systems under: Important instructions and manuals for operating the device (Page 11) or Technical specifications of the operating systems (Page 158). Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Printed documents • Quick Install Guide for the device with link and QR code to the online form for quality control (quality control notification) in the SIEMENS After Sales Information System (ASIS) • Product Information "Important notes on your device"...
The following illustrations are examples. The data of your device may differ from the data in these examples. Nameplate The nameplate is located inside the front door. Example: SIMATIC IPC RW-545A nameplate (the information on the nameplate is device- specific) Identification data of the device ①...
The device can be installed horizontally in control cabinets and 19" rack systems. When telescopic rails are used for mounting, the device can be withdrawn fully from the cabinet or rack. Note the information in "Technical specifications of the telescopic rails (Page 157)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
It is essential that you follow the installation and mounting instructions under: • Safety instructions for assembly (Page 42) • Safety instructions on ambient and environmental conditions (Page 44) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 56
You can find the dimensions for the drill holes under "Dimension drawing for drill holes for telescopic rails (Page 162)". You can find detailed information on the telescopic rails under: "Technical specifications of the telescopic rails (Page 157)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
The power supply cable and the device plug must bear the prescribed markings. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
• The permissible rated voltage of the device must match the local mains voltage. • Operate the device only in grounded electricity grids (TN networks in accordance with VDE 0100 Part 100 or IEC 60364-1). • Operation via non-grounded or impedance-grounded grids is prohibited. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 59
5. To prevent unintentional removal of the power plug, secure the power plug on the device. 6. Remove the retaining screw ①. 7. Screw on the power plug latch ② with the fixing screw ①. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
3. Insert the power cable in the electrical socket. 4. Switch on the device at the on-off switch (position |). 5. To prevent unintentional removal of the power plug, secure the power plug on the device. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
• For control cabinet mounting: Use a central, easily accessible AC circuit breaker close to the device, if possible. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
1. Connect the I/O devices to the respective interfaces. Information on the position of the interfaces is available in "Device ports (Page 20)". 2. Secure the cables (Page 72) with a strain relief. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
You will find 3 additional connection sockets on the rear of the device for connecting monitors to the optional NVIDIA T400 graphics card. • 3 x mDP (Mini DisplayPort) At these connection sockets, you can use adapters to connect monitors to other graphics ports. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 64
Monitor 6 (DisplayPort) Monitor 7 (DisplayPort) Labeling on the device via adapter, see "Hardware accessories (Page 32)" Requirement • You have observed the information in the following sections: "Connecting external devices (Page 62)" Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
You can find information on the connection sockets on the rear of the device under: "Device ports (Page 20)". You can find information on the adapters under "Hardware accessories (Page 32)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 66
Monitor 7 (DisplayPort) Monitor 8 (DisplayPort) Labeling on the device via adapter, see "Hardware accessories (Page 32)" Requirement • You have observed the information in the following sections: "Connecting external devices (Page 62)" Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
• 4 x DisplayPort You can find information on the connection sockets on the rear of the device under: "Device ports (Page 20)". You can find information on the adapters under "Hardware accessories (Page 32)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 68
Monitor 7 (DisplayPort) Monitor 8 (DisplayPort) Labeling on the device via adapter, see "Hardware accessories (Page 32)" Requirement • You have observed the information in the following sections: "Connecting external devices (Page 62)" Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
• 4 x DisplayPort You can find information on the connection sockets on the rear of the device under: "Device ports (Page 20)". You can find information on the adapters under "Hardware accessories (Page 32)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 70
Monitor 7 (DisplayPort) Monitor 8 (DisplayPort) Labeling on the device via adapter, see "Hardware accessories (Page 32)" Requirement • You have observed the information in the following sections: "Connecting external devices (Page 62)" Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Control level. Additional information is available under SIMATIC NET (http://w3.siemens.com/mcms/automation/en/industrielle- kommunikation/Seiten/Default.aspx). The software package and the documentation are not included in the scope of delivery Additional information You can find additional information on the Internet at: Technical support (https://support.industry.siemens.com) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
4. Fasten the cables to the corresponding openings in the strain relief ④ using simple cable ties. Example: Cable fastened to strain relief with cable ties Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
1. Select: "Advanced > Power Management > Restore AC after Power Loss". 2. Assign the "Always on" value to the firmware setting "Restore AC after Power Loss". See also Important instructions and manuals for operating the device (Page 11) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
• Then pull out the power plug or operate the central AC circuit breaker if installed in a control cabinet. Therefore, when installing the device in a control cabinet, ensure that the AC circuit breaker is easily accessible. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 75
Hardware reset with reset button: • Press the reset button. – The device switches off and on again. Information on the position of the buttons is available under "On-off button and reset button (Page 24)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 76
Commissioning the device 5.3 Switching off the device Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
To connect several monitors to the device at the same time (multi-monitoring), you can install a graphics card. You can find information on this here: • Connecting several monitors (multi-monitoring) (Page 63) • Installing a graphics card (Page 102) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Numbering of the drives for "Intel® Optane™ Memory and Storage Management" and the device Note Different numbering of the drives Note the different numbering of the drives for "Intel® Optane™ Memory and Storage Management" and the device. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Memory and Storage Management" software. Requirement • The drives required for the onboard RAID system are built into the device, see information under: – Onboard RAID1 system: Installation options for SATA drives (Page 79) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 80
– In the list, the mounted drive is marked with an "X" ②. – You can find the assignment of the drive to the mounting location in the device ③ in front of the drive model designation. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
RAID system (Page 78)". 2. Right-click on a drive from the list or on "Volume". Status displays are shown for functions and components of the drives or the onboard RAID system. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Configure the mounted drive under "Create Raid Volume". Mount new drive during operation in the onboard RAID system (after an error has occurred) Requirement The system is configured to mount new drives manually (not automatically), see above. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 83
4. From the drive information, select the function "Mark as spare" ③. The drive is mounted to the onboard RAID system and appears in the mounted drives area. See also Data synchronization in the RAID system (Page 84) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Monitoring of the device 6.5.1 Monitoring functions Note No support of monitoring functions by SIMATIC DiagBase or SIMATIC DiagMonitor The SIMATIC DiagBase and SIMATIC DiagMonitor software do not support the monitoring functions of this device. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 85
The power supply units do not report a fan error. If the fan of the power supply unit fails or is defective, no fan alarm is output. The device switches off automatically to protect against overheating. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Device requirements for remote maintenance with Intel® AMT The following device requirements must be met for using Intel® Active Management Technology (iAMT): • Processor that supports iAMT technology • Connection to the network Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
4. Assign the "Enabled" value to the firmware setting "AMT BIOS Features". 5. Press the button <F4> (Save & Exit) and confirm the subsequent dialog with <Y>. 6. Switch off the device or restart it. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
– A special character . ! @ # $ % ^ & * Note The underscore and blank space are valid password characters but do not increase password complexity. 7. Now configure the Intel® AMT functions in the Options of the MEBx (Page 89). Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
4. Assign the "Enabled" value to the firmware setting "Unconfigure ME". 5. Press the button <F4> (Save & Exit Setup) and confirm the subsequent dialog with <Y>. 6. Switch off the device or restart the device. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Use of the Trusted Platform Module is subject to legal restrictions in some countries and is not permitted there. • Always observe the respective import restrictions of the country in which the device will be used. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 91
6.7 Trusted Platform Module (TPM) Activating the Trusted Platform Module You can find information on activating the Trusted Platform Module in the detailed firmware/BIOS description in "Important instructions and manuals for operating the device (Page 11)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
2. Unplug all connecting cables. 3. Open the front panel. (Page 77) 4. Unscrew the locking screw of the enclosure cover ①. 5. Push the enclosure cover back. 6. Lift up and remove the enclosure cover. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
⑤ from the card retainer and install it in the opposite hole. If you are installing a low-profile expansion card, use one of the longer card holders that are shipped with the device for mounting. 10.Close the device. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
The memory transaction rate depends on the combination of memory modules used. Depending on the combination of memory modules used, the actual memory transaction rate can take the following values due to the system: – 4400 MT/Sec. – 4000 MT/Sec. – 3600 MT/Sec. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 96
• In case of operating errors, it may be sufficient to remove one or two memory modules or to use a memory module with lower capacity so that the physical memory expansion on the motherboard and the reserved memory of the expansion card do not overlap. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
• Memory module 1: DIMM_A1 slot • Memory module 2: DIMM_A2 slot • Memory module 3: DIMM_B1 slot • Memory module 4: DIMM_B2 slot The slots of the memory modules are labeled on the motherboard. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 98
7. To prevent tilting, press evenly on both sides of the memory module ② until the lock audibly engages. 8. Close the device. Display of a changed memory configuration A changed memory allocation is automatically recognized when the device is switched on. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
2. Open the device. Be sure to follow the important instructions under "Open the device (Page 93)". 3. To obtain better access to the memory modules, remove expansion cards (Page 95) if required. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
2. Open the device. Be sure to follow the important instructions under "Open the device (Page 93)". 3. Insert the USB stick into the socket of the internal USB interface on the motherboard (Page 167). Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 101
(Page 19)". 6. Slide the bar of the retainer ③ onto the USB stick. 7. Fix the retainer by turning the screw ② on the guide rail. 8. Close the device. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
You can find information on this in the firmware description of the device, see "Important instructions and manuals for operating the device (Page 11)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 103
2. To open the firmware settings, press the <Del> or <Esc> button during the boot phase, when a boot message appears. 3. Select "Advanced" > "Graphics Configuration". 4. Assign the "Auto" value to the firmware setting "Primary Display". See also Service and support (Page 175) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
You can install up to six drives at the following bays in the drive cage type A and on the side panel of the device. Note The 4 SATA connectors on the motherboard of the device support the use of 4 drives. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 105
2 x internal in the device • 2 x HDD inside on the side panel of the device (Page 121) 1 If more than 4 drives are used, an additional controller is required Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Fully disconnect the device from the line voltage, see "Switching off the device (Page 74)". 2. Open the front panel (Page 77). 3. Open the lock of the removable tray with the appropriate key. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 107
Ensure that the removable tray fits tightly in the drive cage. 11.Close the tray bracket. 12.Lock the removable tray with the key. Note The removable tray must always be locked to ensure reliable operation of the devices with removable trays. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
– Press on the surfaces ① on the two side mounting bars ② of the 5.25" component. – Press and hold surface ① to push the 5.25" component forward out of the drive holder ④. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 109
9. Make sure that the removable tray is firmly seated in the 5.25" mounting frame. 10.Close the tray bracket. 11.Lock the removable tray with the key. 12.Close the device. 13.Connect the power supply. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
1. Fully disconnect the device from the line voltage, see "Switching off the device (Page 74)". 2. Open the device. Be sure to follow the important instructions under "Open the device (Page 93)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 111
5. On the front of the drive cage, remove the cover ③, which may be located to the right of the cover ②. 6. Remove all existing removable trays until the drive cage is freely accessible. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
A and is equipped with interfaces for data cables to the motherboard. This enables the convenient connection of the data cables from the motherboard to the drive in the removable tray at these interfaces. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 113
3. Unlatch the backplane by firmly pressing on the latches ② in the direction of the arrow and simultaneously pressing on the ejector ③. 4. Remove the unlatched backplane board ④ by turning it upwards from the brackets and removing it from the drive cage. 5. Close the device. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
2 x internal in the device • 2 x HDD inside on the side panel of the device (Page 121) If more than 4 drives are used, an additional controller is required Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 115
You can implement the following drive configurations in the drive cage type B and on the side panel of the device. • Non-RAID system • RAID1 system • RAID5 system • RAID1 system with hot spare drive • RAID5 system with hot spare drive Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
1. Fully disconnect the device from the line voltage, see "Switching off the device (Page 74)". 2. Open the device. Be sure to follow the important instructions under "Open the device (Page 93)". 3. Remove all power supply and data cables from the drive. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 117
6. Remove the left and right drive mounting bars ② and the drive cover③ from the drive. Note: The drive cover is labeled "L" ④ and "TOP" ⑤. The drive mounting bars are labeled "L" and "R" respectively. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 118
10.Attach the left and right drive mounting bars ② on the drive bay ⑥. 11.Slide the drive bay evenly and without tilting 3/4 (not completely) into the guide rail of the drive cage. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
1. Fully disconnect the device from the line voltage, see "Switching off the device (Page 74)". 2. Open the device. Be sure to follow the important instructions under "Open the device (Page 93)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 120
6. Slide the new drive with the drive mounting bars evenly backwards into the guide rails of the drive cage and without tilting, until it clicks into place. 7. Close the device. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
2. Screw from outside the drive bay plate on the inside to the side panel of the enclosure, at position ① or position ②. The SATA connections each lie in the middle ③. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 122
7.6 Installing and removing drives 3. Connect the SATA cables to the required SATA connectors of the motherboard (Page 167) and to the drive (position ③). 4. Close the device. 5. Connect the power supply unit. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
4. Insert the M.2 NVMe SSD ③ slightly inclined from above into the slot parallel to the motherboard. 5. Carefully press down M.2 NVMe SSD. 6. Fix the end of the M.2 NVMe SSD to the motherboard with a screw. 7. Close the device. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 124
Expanding and assigning parameters to the device 7.6 Installing and removing drives Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Component Replacement interval Drives 3 years Backup battery 5 years 3 years Filter mat of the fan (front fan) Depending on the degree of soiling Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
1. Remove the filter mat from the fan cover. 2. Insert the new filter mat loosely into the fan cover. Place the filter mat evenly in the fan cover. 3. Replace the fan cover. See also Maintenance intervals (Page 125) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
6. Press on the clip on the small fan cable plug connector ② and remove the connector from the larger adapter plug, 7. Press on the side of the clips ③ and loosen the adapter plug from the cable holder. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 128
14.Insert the small fan cable connector ② in the larger adapter connector again. 15.Place the fan support with the new fan on the front of the device. See also Maintenance intervals (Page 125) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
The fan holder is labeled as follows: – At the top with "Top" – At the bottom with arrows which indicate the direction of rotation and air flow of the fan. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Replace spent batteries promptly, see information under "Maintenance intervals (Page 125)". WARNING Risk of explosion and release of harmful substances Before replacing the backup battery, take note of the important safety instructions regarding battery replacement under "General safety instructions (Page 37)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 131
The battery is unlocked and disengages from the socket. 5. Remove the battery from socket. 6. Insert the new battery into the socket with slight pressure and lock it into place. 7. Close the device. 8. Check the firmware settings. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
9. Connect the cables to the drives and the motherboard. 10.Secure the power supply unit cables in the device again using cable ties. 11.Close the device. 12.Check the safe state of the device. 13.Switch on the power supply unit. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
9. Connect the cables to the drives and the motherboard. 10.Secure the power supply unit cables in the device again using cable ties. 11.Close the device. 12.Check the safe state of the device. 13.Switch on the power supply unit. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
4. Insert the new module and push it to the rear edge of the enclosure until it clicks into place there. 5. Re-insert the power plug into the socket ① of the newly inserted module. 6. Check the safe state of the device. Check the correct function on the status display. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
11.Replace the two modules of the redundant power supply unit and push them to the rear edge of the enclosure until they click into place. 12.Insert the power plugs into the sockets of the inserted modules. 13.Check the safe state of the device. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
4. Lift the release lever ④ and release the processor bracket ①. 5. Carefully lift the release lever ④ upwards. When doing so, ensure that you do not let go of the release lever. Illustration of processor socket without processor Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
For information on the firmware settings in the user manual (UM) for the motherboard, see "Important instructions and manuals for operating the device (Page 11)". • Screwdriver TORX T10 Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
For information on restoring the operating system you ordered with the device in the detailed description of the operating system, see "Important instructions and manuals for operating the device (Page 11)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
1. On the Internet, go to "Online Service Delivery Portal (https://www.automation.siemens.com/swdl/register/ipc)". 2. Log in with your credentials or register. 3. Enter the serial number and article number of the device for which you want to install software or drivers. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Note If your device no longer boots, for example, after operating system crash during a firmware update, contact your local SIEMENS contact person. Recycling and disposal The devices described in these operating instructions can be recycled thanks to their low level of pollutants.
Power supply unit 550 W: • Continuous current at 100 V: ≤ 8 A • Continuous current at 230 V: ≤ 4 A • At startup ≤ 80 A for 3.6 ms Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 142
300 W secondary: • ≤ 270 W with 85% efficiency Power loss, heat emission Power supply unit 550 W: • 300 W = 300 J/s = 0.28 BTU/s Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 143
Protection class I compliant with IEC 61140 Safety regulations • IEC 61010-2-201 • EN 61010-2-201 • UL 61010-2-201 • CAN/CSA C22.2 No 61010-2-201 See also Safety instructions on ambient and environmental conditions (Page 44) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
The requirements of the expansion card for the temperature of the intake air (inside the device) must be observed. Operation only permissible in conjunction with power supply unit 850 W Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
± 5% +5 V +5%, -3% The total output of the +5 V and +3.3 V voltage must be ≤ 150 W. The total output of all voltages is max. 550 W. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
+5 V 3.0 A +5%, -3% The total output of the +5 V and +3.3 V voltage must be ≤ 130 W. The total output of all voltages is max. 700 W. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
80% AM to IEC 61000-4-3 • 10 V; 10 kHz up to 80 MHz 80% AM to IEC 61000-4-6 Immunity to magnetic fields 30 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
The device must be free of any mechanical faults when disk drives are installed in the removable trays. See also Installation options for drives with drive cage type A (Page 104) Installation options for drives with drive cage type B (Page 114) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Slots for memory modules 4 x DIMM sockets for DDR5 4400 MHz, expandable to 128 GB Main memory 8 to 128 GB, DDR5 See also Technical specifications of the expansion card slots (Page 150) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
• 3.3 V; 3 A • Gen. 4 • 12 V; 5.5 A • Active lanes: 8 • 3.3 V ; 0.4 A Power loss of the slot, permitted: ≤ 75 W Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 151
In sum, the current for 3.3 V must not exceed 1.2 A. Mounting position for graphics card ① Slot 1 (slot 2 cannot be used for graphics card NVIDIA RTX A2000 and RTX A5000) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
5120 × 2880 at 60 Hz; 32-bit color depth • up to 3x DVI: 1920 × 1200 at 60 Hz; 32-bit color depth • up to 3x VGA: 2048 × 1536 at 60 Hz; 32-bit color depth Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 153
Maximum resolution • Up to 4x DVI: with adapter: 1920 × 1200 at 60 Hz; 32-bit color depth • Up to 4x VGA: 2048 × 1536 at 60 Hz; 32-bit color depth Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 154
The NVIDIA RTX A4000 and NVIDIA RTX A5000 graphics cards can only be connected, operated and configured for SIMATIC IPC RW-545A for devices with power supply unit 850 W. The NVIDIA RTX A4000 and NVIDIA RTX A5000 graphics card is then supplied with a voltage of 12 V via the slot on the motherboard and via an 6-pin or 8-pin plug-in connector.
24-pin (5 V; 500 mA) USB Type A USB Type A: • High-current USB Type C USB Type C: • High-current 5 V; 1.5 A; up to 10 Gbps Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 156
Realtek ALC887, 8-channel DAC support Line IN (light blue) – Headphone OUT (pastel green) – 1: Ground (max. 2 W at 4 Ω) 2: Audio links Microphone IN (pink) – 3: Audio right Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
M5 x 6 mm The mounting screws of the telescopic rails may not protrude by more than 5 mm into the enclosure. See also Dimension drawing for drill holes for telescopic rails (Page 162) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
10.1 Dimension drawing of the device Note IEC60297_3_100 The system meets the requirements for 4 U according to IEC60297_3_100. All dimensions in mm. ① Upper side of the device when installed vertically Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Dimension drawings 10.2 Dimension drawing of the Tower Kit 10.2 Dimension drawing of the Tower Kit Front view and top view All dimensions in mm. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
• Device with extender: 339 mm ② Height of the expansion card PCI: 106.7 mm (free space via expansion card: 38.3 mm) PCIe: 111.2 mm (free space via expansion card: 33.8 mm) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
800 mm cabinet; TS 3659.191 Dimensions of Heitec telescopic rails • for 600 mm cabinet; RP 3659.181 • for 800 mm cabinet; RP 3659.191 ② Dimensions of Schroff telescopic rails; Type 20110-072 Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Certificates and approvals 11.1.1 ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001. This has been certified by DQS (the German society for the certification of quality management systems).
Emission standard for residential, commercial and light-industrial environments. 11.1.8 Eurasion Customs Union EAC Identification for Eurasion Customs Union • EAC (Eurasian Conformity) • Declaration of conformity according to Technical Regulations of the Customs Union (TR Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
• 2014/35/EU "Electrical equipment for use within specific voltage limits" (Low-Voltage Directive). Conformance with this standard has been verified according to EN 61010-2-201. • 2011/65/EU "Restriction of the use of certain hazardous substances in electrical and electronic equipment" (RoHS Directive) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 166
Standards and approvals 11.2 Directives and declarations Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Sum of the currents on the USB ports of the device (including the internal USB ports) ≤ 3 A Technical features of the motherboard Technical features of the motherboard can be found under "General technical specifications of the motherboard (Page 149)". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
PIRQ C PIRQ C INT D PIRQ D PIRQ A PIRQ D PIRQ D PIRQ D PIRQ D PIRQ D PIRQ D PIRQ D Organizationa l Pins Request REQ0 Grant GNT0 AD16 Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Windows®: 1. Press the "Windows® key" and "R" simultaneously. The "Run" dialog box opens. 2. Enter "msinfo32" in the "Open" field. 3. Confirm your entry with "OK". Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
TIA Portal. Slot Designation on the motherboard TIA Portal Number on the enclosure PCIE4X16_1 X100 PCIE3_X8_1 X101 PCIE4X16_2 X102 PCIE3_X4_1 X103 PCIE4_X4_1 X104 PCIE_X4_2 X105 PCI1 X106 Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 174
Hardware description A.4 Assignment of expansion interfaces to the software in the TIA Portal (CP assignment) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
You can find additional information and support for the products described on the Internet at the following addresses: • Technical support (https://support.industry.siemens.com) • Support request form (https://www.siemens.com/supportrequest) • After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) • SIMATIC Documentation Collection (https://www.siemens.com/simatic-tech-doku-portal) • Your local representative (https://www.automation.siemens.com/aspa_app) • Training center (https://siemens.com/sitrain) •...
Time and/or date of the PC is 1. Open the firmware configuration menu. To do not correct this, press the <F2> key during the boot operation. 2. Set the date and the time in the "Main" tab. Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
You can find the files and descriptions needed for GPT data storage medium is this on the supplied data storage medium. aborted with the following error message: "Status: 0xc0000225 Info: The boot selection failed because a required device is inaccessible" Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Different pin assignment expansion card and restart the device. If the error no longer occurs, the expansion card was the cause of the fault. Replace this with a Siemens expansion card or contact the supplier of the expansion card. If the device still crashes, contact your technical support team.
Page 179
Remove the installed expansion card and reinsert is integrated. connector Examples: • Clean the contact surface of the expansion card • The operating system does with pure ethanol. not boot. • The expansion card is not detected Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Attention ESD (Electrostatic sensitive Warning of hot surface device) Disposal information, observe the local regulations. Symbols for operator controls Symbol Meaning Symbol Meaning On-off switch, without electrical isolation On-off button, without electrical isolation Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters Approval for United Kingdom Laboratories Approval for India Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Connection for functional grounding Line Out (Equipotential-bonding cable) DisplayPort interface Microphone input DVI port LAN interface, not approved for connecting WAN or telephone Serial port USB 2.0 high-speed port USB 3.0 Gen 1 SuperSpeed port Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Fehler! Textmarke nicht definiert. Disposal, 140 Backup battery Documentation, 11 Changing, 131 Drive cage type A, 16 Maintenance interval, 125 Installation options for drives, 104 Battery, (Backup battery) possible drive configurations, 106 BIOS, (Firmware settings) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 186
Front fan, 15 Graphics memory, 152 Maintenance interval, 125 Fan cover Acceptance, 126 Front fan, 15 Fan monitoring, 85 Hardware interrupt Fan on the front of the device, (Front fan) Assigning, 169 Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 187
Index Hardware reset, 75 High frequency radiation KC Mark (Korea), 165 Immunity to interference, 45 Korea Holes KC Mark, 165 for telescopic rails, 56 Korean Certification, 165 hot swap Changing the drive in the removable tray, 106 LAN port Status displays, 29 I/O addresses LEDs, (Status displays) Assignment, 170...
Page 188
RCM (Australia/New Zealand), 164 Installing, 139 Recycling, 140 Restore, 138 Redundant 700 W power supply unit Shutdown, 74 Output voltage, 146 Redundant power supply unit Status displays, 30 Remote maintenance, (Intel® AMT) Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...
Page 189
Disconnecting the device from the line voltage, 74 Forced shutdown, (Hardware reset) Hardware reset, 75 Shutting down the operating system, 74 Switching on Configure automatic startup, 73 Switching on the device, 73 Workstation SIMATIC IPC RW-545A Operating Instructions, 08/2023, A5E52943278-AA...