Installing and removing
5.7 Changing the position of the securing bar
5.7

Changing the position of the securing bar

Rail mounting position - wall mounting position
To change the securing bar from the rail mounting position to the wall mounting position
follow the steps below:
1. If necessary, loosen the knurled screw with your hand or a screwdriver.
2. Move the securing bar down as far as it will go.
– Use the levering aid and level the securing bar down using a screwdriver into this position.
– Push the securing bar down using your hand.
3. Hold the securing bar in this position.
– Hold the securing bar with the screwdriver.
– Use the gap on the rear of the device and fix the securing bar briefly with a pin.
4. Tighten the knurled screw (torque 0.5 Nm).
The securing bar is fixed in the wall mounting position.
5. Remove the pin.
Wall mounting position - rail mounting position
To move the securing bar from the wall mounting position to the rail mounting position,
loosen the knurled screw.