53-1001963-01 October 1, 2010 Dell 8/4Gbps FC SAN Module Getting Started Guide 使用入门指南 入門指南 Guide de mise en route Handbuch zum Einstieg Panduan Pengaktifan はじめに 시작 안내서 Guia de Noções Básicas Guía de introducción Başlangıç Kılavuzu 53-1001963-01 *53-1001963-01*...
Page 3
53-1001963-01 October 1, 2010 Dell 8/4Gbps FC SAN Module Getting Started Guide 53-1001963-01 *53-1001963-01*...
Page 4
Trademarks used in this text: Dell, the DELL logo, Inspiron, Dell Precision, Dimension, OptiPlex, Latitude, PowerEdge, PowerVault, PowerApp, PowerConnect, and Dell OpenManage are trademarks of Dell Inc.; Intel, Pentium, and Celeron are registered trademarks of Intel Corporation in the U.S. and other countries; Microsoft, Windows, Windows Server, MS-DOS and Windows Vista are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries.
FC SAN Module. NOTE The FC SAN Module is designed to work only in I/O bays B1/B2 and C1/C2 of the Dell M1000e Blade Server Enclosure. Make sure to comply with installation requirements in the Blade Server Enclosure Hardware Owner’s Manual.
This publication provides procedures that use FC SAN Module Command Line Interface (CLI). For details, refer to the Dell 8/4Gbps FC SAN Module Administrator’s Guide. If the same operation can be performed using the Blade Server chassis management application, use that application instead.
Page 7
From the Hyperterminal window, click the Connect drop-down menu and select an available COM port. d. Click OK. e. From the COM Port Properties window, select the following configuration values: • Bits per second: 9600 • Databits: 8 • Parity: None • Stop bits: 1 Dell 8/4Gbps FC SAN Module Getting Started Guide 53-1001963-01...
Page 8
3. At the login prompt, enter the default user name as “admin” and password as “password”. 4. Use the appropriate CLI commands to change the IP address of the selected FC SAN module. Refer to your Blade Server Enclosure CLI documentation. Dell 8/4Gbps FC SAN Module Getting Started Guide 53-1001963-01...
Page 9
The management workstation must be on the same Ethernet subnet as the CMC. NOTE Ensure that the FC SAN Module is not being modified from any other connection until configuration is complete. Dell 8/4Gbps FC SAN Module Getting Started Guide 53-1001963-01...
Page 10
Repeat for the remaining transceivers as required. 3. Check the LEDs to verify that all components are functional. For information about LED patterns, see the “Operating the FC SAN Module” chapter in the Dell 8/4Gbps FC SAN Module Hardware Reference Manual.
Page 11
For specific instructions about how to back up the configuration, see the Dell 8/4Gbps FC SAN Module Administrator’s Guide. Activating Additional Ports Port upgrade licensing allows you to enable up to 24 ports from the initial 12 ports. Add port upgrade using a Telnet connection;...
Appendix A Regulatory Notices For additional regulatory information, see the Regulatory Compliance Homepage on www.dell.com at the following location: www.dell.com/regulatory_compliance. Información de la NOM (sólo para México) La información que se proporciona a continuación aparece en el dispositivo descrito en este documento, en cumplimiento de los requisitos de la...
Page 13
53-1001963-01 2010 年 10 月 1 日 Dell 8/4Gbps FC SAN 模块 使用入门指南 53-1001963-01 *53-1001963-01*...
Page 15
FC SAN 注 FC SAN B1/B2 Dell M1000e C1/C2 《硬件用户手册》 FC SAN FC SAN FC SAN FC SAN FC SAN FC SAN FC SAN FC SAN 注 FC SAN 《硬件用户手册》 FC SAN FC SAN Dell 8/4Gbps FC SAN 模块入门指南 53-1001963-01...
Page 16
程 程 FC SAN • FC SAN • (KVM) 程 FC SAN • DHCP • FC SAN 程 FC SAN • 注 Dell • FC SAN • • • • Dell 8/4Gbps FC SAN Dell 8/4Gbps FC SAN 模块入门指南 53-1001963-01...
Page 17
FC SAN 程 程 TERM 程 LINUX UNIX FC SAN Windows 95 2000 开始 程 Programs -> Accessories -> Communications 超级终端 连接 COM 端口属性 • 每秒位数:9600 • 数据位数:8 • 奇偶校验:无 • 停止位:1 • 流控制:无 Dell 8/4Gbps FC SAN 模块入门指南 53-1001963-01...
Page 18
利用 CMC CLI 设置 IP 地址 CMC CLI FC SAN 程 CMC CLI connect switch-x FC SAN switch-x • Switch-3 FC SAN • Switch-3 FC SAN • Switch-3 FC SAN • Switch-3 FC SAN admin password FC SAN Dell 8/4Gbps FC SAN 模块入门指南 53-1001963-01...
Page 19
利用 CMC GUI 设置 IP 地址 程 Setup IP Address Subnet Mask Gateway Apply DHCP DHCP Enabled DHCP Apply 图 1 注 程 FC SAN 程 FC SAN (CMC) 注 FC SAN Dell 8/4Gbps FC SAN 模块入门指南 53-1001963-01...
Page 20
该收发机采用锁定式设计,以确保正确定位。如安装收发机过程中遇到困难,确保其方向正确且已移除端盖。 注意 5.08 3.048 / 1.2 Dell 8/4Gbps FC SAN FC SAN switchShow FC SAN FC SAN fabricShow CLI FC SAN configUpload FC SAN FC SAN FC SAN FC SAN Dell 8/4Gbps FC SAN Dell 8/4Gbps FC SAN 模块入门指南 53-1001963-01...
Page 21
程 FC SAN Dell FC SAN FC SAN FC SAN FC SAN 注 FC SAN SAN 之前 FC SAN 注意 FC SAN FC SAN FC SAN FC SAN Dell 8/4Gbps FC SAN 模块入门指南 53-1001963-01...
Page 22
La información que se proporciona a continuación aparece en el dispositivo descrito en este documento, en cumplimiento de los requisitos de la Norma Oficial Mexican (NOM): Importador: Dell Inc. de Mexico, S.A. de C.V. Paseo de la Reforma 2620-11 Piso Col.
Page 23
53-1001963-01 2010 年 10 月 1 日 Dell 8/4Gbps FC SAN 53-1001963-01 *53-1001963-01*...
Page 25
FC SAN FC SAN 註 FC SAN Dell M1000e B1/B2 C1/C2 FC SAN FC SAN FC SAN FC SAN FC SAN FC SAN FC SAN FC SAN 註 FC SAN FC SAN FC SAN Dell 8/4Gbps FC SAN 模組入門指南 53-1001963-01...
Page 26
FC SAN • 註 Dell • FC SAN • • • • 管 Dell 8/4Gbps FC SAN FC SAN FC SAN 10.77.77.77 255.255.255.0 FC SAN • FC SAN (CLI) • CMC CLI • (GUI) Dell 8/4Gbps FC SAN 模組入門指南 53-1001963-01...
Page 27
) -> Communications Hyperterminal ( Connect ( OK ( COM Port Properties (COM • 每秒傳輸位元:9600 • Databit:8 • 同位檢查:無 • 停止位元:1 • 流量控制:無 LINUX UNIX tip /dev/ttyb -9600 Enter 管 admin password 管 Ctrl-C Dell 8/4Gbps FC SAN 模組入門指南 53-1001963-01...
Page 28
使用 CMC CLI 設定 IP 位址 CMC CLI FC SAN CMC CLIE Telnet connect switch-x switch-x FC SAN • Switch-3 FC SAN • Switch-4 FC SAN • Switch-5 FC SAN • Switch-6 FC SAN admin password FC SAN Dell 8/4Gbps FC SAN 模組入門指南 53-1001963-01...
Page 29
Setup ( IP Address (IP ) Subnet Mask ( Gateway ( Apply ( DHCP DHCP Enabled (DHCP Apply ( 圖 1 CMC 設定標籤 註 FC SAN 管 管 FC SAN (CMC) 管 註 FC SAN Dell 8/4Gbps FC SAN 模組入門指南 53-1001963-01...
Page 30
Dell 注意 5.08 3.048 (1.2 Dell 8/4Gbps FC SAN FC SAN switchShow FC SAN FC SAN fabricShow CLI FC SAN configUpload FC SAN FC SAN FC SAN FC SAN 管 Dell 8/4Gbps FC SAN Dell 8/4Gbps FC SAN 模組入門指南 53-1001963-01...
Page 31
Telnet FC SAN Dell FC SAN FC SAN FC SAN FC SAN 註 FC SAN FC SAN 注意 FC SAN FC SAN FC SAN FC SAN Dell 8/4Gbps FC SAN 模組入門指南 53-1001963-01...
Page 32
法規聲明 若欲獲得其他管制資訊,請參閱 www.dell.com 的 Regulatory Compliance 「法規遵循」首頁:www.dell.com/regulatory_compliance。 Información de la NOM (sólo para México) La información que se proporciona a continuacón aparece en el dispositivo descrito en este documento, en cumplimiento de los requisitos de la Norma Oficial Mexican (NOM): Importador: Dell Inc.
Page 33
53-1001963-01 1 Oktober 2010 Modul FC SAN Dell 8/4Gbps Panduan Pengaktifan 53-1001963-01 *53-1001963-01*...
Page 34
Merek dagang dan nama dagang lain mungkin digunakan dalam dokumen ini untuk merujuk ke pihak lain yang memiliki hak kekayaan intelektual atas merek dan nama produk mereka. Dell Inc. menyangkal kepentingan kepemilikan apa pun atas merek dagang dan nama dagang selain miliknya sendiri.
Page 35
Bagian ini berlaku ketika memasang modul baru di dalam tempat kosong atau mengganti Modul FC SAN yang telah ada. CATATAN Modul FC SAN didesain untuk dapat berfungsi hanya pada ruang I/O B1/B2 dan C1/C2 Dell M1000e Blade Server Enclosure. Pastikan Anda sudah memenuhi persyaratan pemasangan pada Manual Perangkat Keras untuk Pemilik Blade Server Enclosure.
Page 36
Modul FC SAN Module via CLI. Publikasi ini menjelaskan prosedur yang menggunakan Modul FC SAN Command Line Interface (CLI). Untuk rincian, bacalah Panduan Administrator Modul FC SAN Dell 8/4Gbps. Jika operasi yang sama dapat dilakukan dengan menggunakan aplikasi manajemen sasis Blade Server, gunakanlah aplikasi itu.
Page 37
Dari jendela COM Port Properties (Properti Port COM), pilih nilai konfigurasi berikut ini: • Bits per second (Bit per detik): 9600 • Databits: 8 • Parity (Paritas): None (Tidak ada) • Stop bits: 1 • Flow Control (Kontrol Aliran): None (Tidak ada) Panduan Pengaktifan Modul Dell 8/4Gbps FC SAN 53-1001963-01...
Page 38
3. Pada perintah login, masukkan nama pengguna dengan “admin” dan sandi dengan “password”. 4. Gunakan perintah CLI yang tepat untuk mengubah alamat IP Modul FC SAN yang dipilih. Lihat dokumentasi Blade Server Enclosure CLI Anda. Panduan Pengaktifan Modul Dell 8/4Gbps FC SAN 53-1001963-01...
Page 39
Chassis Management Controller (CMC) pada workstation manajemen jarak jauh untuk segala konfigurasi tambahan. Workstation manajemen harus berada pada subnet Ethernet yang sama dengan CMC. CATATAN Pastikan bahwa Modul FC SAN tidak sedang dimodifikasi dari koneksi mana pun yang lain hingga konfigurasi diselesaikan. Panduan Pengaktifan Modul Dell 8/4Gbps FC SAN 53-1001963-01...
Page 40
3. Periksa LED untuk memastikan bahwa semua komponen telah berfungsi. Untuk informasi tentang pola LED, bacalah bab “Mengoperasikan Modul FC SAN” pada Manual Referensi Perangkat Keras Modul FC SAN Dell 8/4Gbps. 4. Pastikan operasi Modul FC SAN sudah benar dengan mengetikkan perintah switchShow dari workstation.
Page 41
Jangan gunakan metode ini jika Modul FC SAN beroperasi pada SAN yang sudah ada karena lalu lintas akan diputus. 1. Nonaktifkan Modul FC SAN. 2. Tambahkan lisensi pembaruan port menggunakan CLI. 3. Aktifkan Modul FC SAN menggunakan CLI. Saat Modul FC SAN diaktifkan, port yang baru ditambahkan juga diaktifkan. Panduan Pengaktifan Modul Dell 8/4Gbps FC SAN 53-1001963-01...
Lampiran A Pemberitahuan Peraturan Untuk informasi peraturan tambahan, lihat Laman Utama Pemenuhan Peraturan pada www.dell.com di alamat berikut: www.dell.com/regulatory_compliance. Información de la NOM (sólo para México) La información que se proporciona a continuación aparece en el dispositivo descrito en este documento, en cumplimiento de los requisitos de la...
Page 43
53-1001963-01 Oktober 1, 2010 Dell 8/4Gbps FC SAN-Modul Handbuch zum Einstieg 53-1001963-01 *53-1001963-01*...
Page 44
In diesem Text verwendete Marken: Dell, das DELL-Logo, Inspiron, Dell Precision, Dimension, OptiPlex, Latitude, PowerEdge, PowerVault, PowerApp, PowerConnect und Dell OpenManage sind Marken von Dell Inc.; Intel, Pentium und Celeron sind eingetragene Marken der Intel Corporation in den USA und anderen Ländern; Microsoft, Windows, Windows Server, MS-DOS und Windows Vista sind entweder Marken oder eingetragene Marken der Microsoft Corporation in den USA und/oder anderen Ländern.
Abschnitt. Dieser Abschnitt betrifft die Installation eines neuen Moduls in einem leeren Schacht bzw. das Aus- tauschen eines vorhandenen FC SAN-Moduls. ANMERKUNG Das FC SAN-Modul wurde nur für den Einsatz in den E/A-Schächten B1/B2 und C1/C2 des Dell M1000e Blade Server-Gehäuses konzipiert. Stellen Sie sicher, dass Sie die Installationsanforderungen des Blade Server-Gehäuse Hardware-Benutzerhandbuchs erfüllen.
Page 46
Diese Veröffentlichung enthält Vorgehensweisen, die die CLI (Command Line Interface) des FC SAN-Moduls verwen- den. Beziehen Sie sich für Einzelheiten auf das Dell 8/4Gbps FC SAN-Modul Administratorhandbuch. Wenn die sel- be Operation unter Verwendung der Blade Server-Gehäuseverwaltung durchgeführt werden kann, dann verwenden Sie stattdessen diese Anwendung.
Page 47
Terminalemulationsanwendung (wie z.B. HyperTerminal auf einem PC oder TERM in einer LINUX- bzw. UNIX- Umgebung) verwenden. Diese Verbindung wird verwendet, wenn Sie die IP-Adresse des Moduls unter Verwen- dung von CLI-Befehlen zurücksetzen wollen und wenn Sie andere Konfigurationsaufgaben durchführen wollen. Dell 8/4Gbps FC SAN-Modul Handbuch zum Einstieg 53-1001963-01...
Page 48
Fibre Channel Subnetmask [none]: Gateway IP Address [0.0.0.0]:10.32.48.1 DHCP [Off]: IP address is being changed...Done (IP-Adresse wird geändert...Fertig). 3. Geben Sie in der Eingabeaufforderung ipAddrShow ein, um zu überprüfen, dass die Adresse richtig eingestellt wurde. Dell 8/4Gbps FC SAN-Modul Handbuch zum Einstieg 53-1001963-01...
Page 49
3. Geben Sie in der Eingabeaufforderung „admin“ als Standardbenutzernamen und „password“ als Kennwort ein. 4. Verwenden Sie die entsprechenden CLI-Befehle, um die IP-Adresse des gewählten FC SAN-Moduls zu ändern. Lesen Sie in der CLI-Dokumentation des Blade Server-Gehäuses nach. Dell 8/4Gbps FC SAN-Modul Handbuch zum Einstieg 53-1001963-01...
Page 50
Konfigurationen vorzunehmen. Die Verwaltungs-Workstation muss sich auf demselben Ethernet- Subnetz befinden wie der CMC. ANMERKUNG Stellen Sie sicher, dass das FC SAN-Modul nicht durch irgendwelche anderen Verbindungen geändert wird, bis die Konfiguration abgeschlossen ist. Dell 8/4Gbps FC SAN-Modul Handbuch zum Einstieg 53-1001963-01...
Page 51
Wiederholen Sie dies für die verbleibenden Sender-Empfänger, wie erforderlich. 3. Überprüfen Sie die LEDs, um die Funktionstüchtigkeit aller Komponenten zu bestätigen. Lesen Sie für Informationen über die LED-Muster das Kapitel „Bedienung des FC SAN-Moduls“ im Dell 8/4Gbps FC SAN-Modul Hardware-Referenzhandbuch.
Page 52
Ersatz-FC SAN-Modul zur Verfügung steht, falls benötigt. Wir empfehlen das regelmäßige Sichern der Konfiguration, um sicherzustellen, dass für das Herunterladen auf ein Ersatz-FC SAN-Modul eine vollständige Konfiguration zur Verfügung steht. Lesen Sie für spezifische Anweisungen zum Sichern der Konfiguration im Dell 8/4Gbps FC SAN-Modul Administratorhandbuch nach. Aktivieren zusätzlicher Ports Portaktualisierungslizenzierung ermöglicht es Ihnen, ausgehend von den anfänglichen 12 Ports bis zu 24 Ports zu...
Page 53
Anhang A Betriebsbestimmungen Weitere Informationen zu Bestimmungen finden Sie auf unserer Website www.dell.com unter www.dell.com/regulatory_compliance Información de la NOM (sólo para México) La información que se proporciona a continuación aparece en el dispositivo descrito en este documento, en cumplimiento de los requisitos de la...
Page 54
Dell 8/4Gbps FC SAN-Modul Handbuch zum Einstieg 53-1001963-01...
Page 55
53-1001963-01 1 Oktober 2010 Modul FC SAN Dell 8/4Gbps Panduan Pengaktifan 53-1001963-01 *53-1001963-01*...
Page 56
Merek dagang dan nama dagang lain mungkin digunakan dalam dokumen ini untuk merujuk ke pihak lain yang memiliki hak kekayaan intelektual atas merek dan nama produk mereka. Dell Inc. menyangkal kepentingan kepemilikan apa pun atas merek dagang dan nama dagang selain miliknya sendiri.
Page 57
Bagian ini berlaku ketika memasang modul baru di dalam tempat kosong atau mengganti Modul FC SAN yang telah ada. CATATAN Modul FC SAN didesain untuk dapat berfungsi hanya pada ruang I/O B1/B2 dan C1/C2 Dell M1000e Blade Server Enclosure. Pastikan Anda sudah memenuhi persyaratan pemasangan pada Manual Perangkat Keras untuk Pemilik Blade Server Enclosure.
Page 58
Modul FC SAN Module via CLI. Publikasi ini menjelaskan prosedur yang menggunakan Modul FC SAN Command Line Interface (CLI). Untuk rincian, bacalah Panduan Administrator Modul FC SAN Dell 8/4Gbps. Jika operasi yang sama dapat dilakukan dengan menggunakan aplikasi manajemen sasis Blade Server, gunakanlah aplikasi itu.
Page 59
Dari jendela COM Port Properties (Properti Port COM), pilih nilai konfigurasi berikut ini: • Bits per second (Bit per detik): 9600 • Databits: 8 • Parity (Paritas): None (Tidak ada) • Stop bits: 1 • Flow Control (Kontrol Aliran): None (Tidak ada) Panduan Pengaktifan Modul Dell 8/4Gbps FC SAN 53-1001963-01...
Page 60
3. Pada perintah login, masukkan nama pengguna dengan “admin” dan sandi dengan “password”. 4. Gunakan perintah CLI yang tepat untuk mengubah alamat IP Modul FC SAN yang dipilih. Lihat dokumentasi Blade Server Enclosure CLI Anda. Panduan Pengaktifan Modul Dell 8/4Gbps FC SAN 53-1001963-01...
Page 61
Chassis Management Controller (CMC) pada workstation manajemen jarak jauh untuk segala konfigurasi tambahan. Workstation manajemen harus berada pada subnet Ethernet yang sama dengan CMC. CATATAN Pastikan bahwa Modul FC SAN tidak sedang dimodifikasi dari koneksi mana pun yang lain hingga konfigurasi diselesaikan. Panduan Pengaktifan Modul Dell 8/4Gbps FC SAN 53-1001963-01...
Page 62
3. Periksa LED untuk memastikan bahwa semua komponen telah berfungsi. Untuk informasi tentang pola LED, bacalah bab “Mengoperasikan Modul FC SAN” pada Manual Referensi Perangkat Keras Modul FC SAN Dell 8/4Gbps. 4. Pastikan operasi Modul FC SAN sudah benar dengan mengetikkan perintah switchShow dari workstation.
Page 63
Jangan gunakan metode ini jika Modul FC SAN beroperasi pada SAN yang sudah ada karena lalu lintas akan diputus. 1. Nonaktifkan Modul FC SAN. 2. Tambahkan lisensi pembaruan port menggunakan CLI. 3. Aktifkan Modul FC SAN menggunakan CLI. Saat Modul FC SAN diaktifkan, port yang baru ditambahkan juga diaktifkan. Panduan Pengaktifan Modul Dell 8/4Gbps FC SAN 53-1001963-01...
Page 64
Lampiran A Pemberitahuan Peraturan Untuk informasi peraturan tambahan, lihat Laman Utama Pemenuhan Peraturan pada www.dell.com di alamat berikut: www.dell.com/regulatory_compliance. Información de la NOM (sólo para México) La información que se proporciona a continuación aparece en el dispositivo descrito en este documento, en cumplimiento de los requisitos de la...
Page 65
53-1001963-01 2010 Dell 8/4Gbps FC SAN 53-1001963-01 *53-1001963-01*...
Page 67
A ............. . . 72 Dell 8/4Gbps FC SAN Dell 8/4Gbps FC SAN Module Hardware User's Manual Dell 8/4Gbps FC SAN Module Administrator's Guide FC SAN Module FC SAN FC SAN Module メモ...
Page 68
FC SAN FC SAN FC SAN 17 18 19 20 21 22 23 FC SAN FC SAN FC SAN FC SAN Dell 8/4Gbps FC SAN Module Administrator's Guide FC SAN Module • FC SAN Module FC SAN • パ FC SAN •...
Page 69
FC SAN Module FC SAN FC SAN FC SAN パ LINUX/UNIX TERM FC SAN Module Windows 95 98 2000 XP NT -> -> パ • ビット / 秒:9600 • データビット:8 • パリティ:なし • ストップビット:1 • フロー制御:なし Dell 8/4Gbps FC SAN 53-1001963-01...
Page 70
CMC CLI を使用した IP アドレスの設定 CMC CLI FC SAN CMC CLI Telnet connect switch-x FC SAN Module switch-x • FC SAN Switch-3 • FC SAN Switch-4 • FC SAN Switch-5 • FC SAN Switch-6 パ admin password FC SAN Dell 8/4Gbps FC SAN 53-1001963-01...
Page 71
CMC GUI を使用した IP アドレスの設定 DHCP 図 1 メモ FC SAN FC SAN Module Chassis Management Controller CMC メモ FC SAN Module Dell 8/4Gbps FC SAN 53-1001963-01...
Page 72
FC SAN メモ FC SAN Module a b c メモ Dell 注目 5.08 cm 3.048 cm パ Dell 8/4Gbps FC SAN FC SAN switchShow FC SAN Module FC SAN Module fabricShow FC SAN Module configUpload FC SAN Module FC SAN Module...
Page 73
Telnet FC SAN FC SAN Module FC SAN Module FC SAN FC SAN Module メモ FC SAN Module FC SAN Module 注目 FC SAN Module FC SAN Module FC SAN Module FC SAN Module Dell 8/4Gbps FC SAN 53-1001963-01...
Page 74
La información que se proporciona a continuación aparece en el dispositivo descrito en este documento, en cumplimiento de los requisitos de la Norma Oficial Mexican (NOM): Importador: Dell Inc. de Mexico, S.A. de C.V. Paseo de la Reforma 2620-11º Piso Col. Lomas Altas 11950 Mexico, D.F.
Page 75
53-1001963-01 2010 Dell 8/4Gbps FC SAN 53-1001963-01 *53-1001963-01*...
Page 77
A ............82 Dell 8/4Gbps FC SAN , Dell 8/4Gbps FC SAN Module Hardware User’s Manual (Dell 8/4Gbps FC SAN Dell 8/4Gbps FC SAN Module Administrator’s Guide...
Page 78
FC SAN • (HyperTerminal (KVM) FC SAN • DHCP • , FC SAN FC SAN • , SFP 주 Dell SFPs • FC SAN • • • • Dell 8/4Gbps FC SAN Dell 8/4Gbps FC SAN 모듈 시작 안내서 53-1001963-01...
Page 79
Windows 95, 98, 2000, XP -> -> e. COM • 초당 비트 : 9600 • 데이터비트 : 8 • 패리티 : 없음 • 중지 비트 : 1 • 흐름 제어 : 없음 Dell 8/4Gbps FC SAN 모듈 시작 안내서 53-1001963-01...
Page 80
FC SAN 1. CMC CLI Telnet FC SAN connect switch-x , switch-x 될 • FC SAN Switch-3. • FC SAN Switch-4. • Switch-5. FC SAN • FC SAN Switch-6. “admin” “password” FC SAN Dell 8/4Gbps FC SAN 모듈 시작 안내서 53-1001963-01...
Page 81
CMC GUI 를 이용하여 IP 주소 설정하기 1. CMC Setup( 2. IP Apply( 3. DHCP , DHCP Enabled(DHCP Apply( 그림 3 주 FC SAN FC SAN (CMC) 주 될 FC SAN Dell 8/4Gbps FC SAN 모듈 시작 안내서 53-1001963-01...
Page 82
3. LEDs Dell 8/4Gbps FC SAN “FC SAN ” switchShow FC SAN FC SAN fabricShow CLI FC SAN 6. configUpload FC SAN FC SAN FC SAN FC SAN , Dell 8/4Gbps FC SAN Dell 8/4Gbps FC SAN 모듈 시작 안내서 53-1001963-01...
Page 83
FC SAN FC SAN FC SAN SANs FC SAN 1. CLI 2. CLI 주 FC SAN FC SAN 주의 FC SAN 1. FC SAN 2. CLI 3. CLI FC SAN . FC SAN Dell 8/4Gbps FC SAN 모듈 시작 안내서 53-1001963-01...
Page 84
규정사항 자세한 규정 정보는 www.dell.com 에서 규정준수 홈페이지 : 를 참조하십시오 . www.dell.com/regulatory_compliance Información de la NOM (sólo para México) La información que se proporciona a continuación aparece en el dispositivo descrito en este documento, en cumplimiento de los requisitos de la...
Page 85
53-1001963-01 1 de outubro de 2010 Módulo SAN de Canal de Fibra de 8/4Gbps da Dell Guia de Noções Básicas 53-1001963-01 *53-1001963-01*...
Page 86
Outras marcas e nomes comerciais podem ser usados neste documento como referência às entidades que reivindicam essas marcas e nomes ou a seus produtos. A Dell Inc. renuncia ao direito de qualquer participação em nomes e marcas comerciais que não sejam de sua propriedade.
Dell 8/4Gbps FC SAN Module Hardware User’s Manual (Manual do usuário de hardware do módulo SAN de Canal de Fibra de 8/4 Gbps da Dell) e Dell 8/4Gbps FC SAN Module Administrator’s Guide (Guia do administrador do módulo SAN de Canal de Fibra de 8/4 Gbps da Dell).
Page 88
Dell 8/4Gbps FC SAN Module Administrator’s Guide (guia do administrador do módulo SAN de canal de fibra de 8/4 Gbps da Dell). Se a mesma operação puder ser executada usando o aplicativo de gerenciamento de chassi do servidor blade, use este aplicativo.
Page 89
Blade Server Enclosure Configuration Guide (Guia de configuração do gabinete do servidor blade) • Dell 8/4Gbps FC SAN Module Administrator’s Guide (Guia do administrador do módulo SAN de Canal de Fibra de 8/4Gbps da Dell) Modificar o endereço IP do módulo SAN de Canal de Fibra Por padrão, o endereço IP do Módulo SAN é...
Page 90
Use o seguinte procedimento para conectar e modificar o endereço IP do Módulo SAN de Canal de Fibra através da interface CLI do CMC. Guia de Noções Básicas do Módulo SAN de Canal de Fibra de 8/4Gbps da Dell 53-1001963-01...
Page 91
4. Use os comandos adequados de linha de comando para mudar o endereço IP do Módulo SAN de Canal de Fibra selecionado. Consulte a documentação da interface CLI do gabinete do servidor blade. Guia de Noções Básicas do Módulo SAN de Canal de Fibra de 8/4Gbps da Dell 53-1001963-01...
Page 92
Ethernet do CMC. NOTA Certifique-se de que o Módulo SAN não esteja sendo modificado a partir de nenhuma outra conexão até que a configuração seja concluída. Guia de Noções Básicas do Módulo SAN de Canal de Fibra de 8/4Gbps da Dell 53-1001963-01...
Page 93
Para obter informações sobre os padrões de LEDs, consulte o capítulo “Operating the FC SAN Module” (Operação do módulo SAN de Canal de Fibra) no manual Dell 8/4Gbps FC SAN Module Hardware Reference Manual (Manual de referência de hardware do módulo SAN de Canal de Fibra 8/4 Gbps da Dell).
Page 94
Módulo SAN de reposição. Para obter instruções específicas sobre como fazer o backup da configuração, consulte o Dell 8/4Gbps FC SAN Module Administrator’s Guide (Guia do administrador do módulo SAN de Canal de Fibra 8/4 Gbps da Dell).
Page 95
Apêndice A Avisos de normalização Para obter informações adicionais de normalização, visite a página inicial de conformidade normativa em www.dell.com no seguinte local: www.dell.com/regulatory_compliance. Información de la NOM (sólo para México) La información que se proporciona a continuación aparece en el dispositivo descrito en este documento, en cumplimiento de los requisitos de la...
Page 96
Guia de Noções Básicas do Módulo SAN de Canal de Fibra de 8/4Gbps da Dell 53-1001963-01...
53-1001963-01 1 de octubre de 2010 Módulo SAN FC de 8/4 Gbps de Dell Guía de introducción 53-1001963-01 *53-1001963-01*...
Page 98
Otras marcas y otros nombres comerciales pueden utilizarse en este documento para hacer referencia a las entidades que los poseen o a sus productos. Dell Inc. renuncia a cualquier interés sobre la propiedad de marcas y nombres comerciales que no sean los suyos.
Dell 8/4Gbps FC SAN Module Hardware User’s Manual (Manual del usuario de hardware del módulo SAN FC de 8/4 Gbps de Dell) y Dell 8/4Gbps FC SAN Module Administrator’s Guide (Guía del administrador del módulo SAN FC de 8/4 Gbps de Dell).
Page 100
Dell 8/4Gbps FC SAN Module Administrator’s Guide (Guía del administrador del módulo SAN FC de 8/4 Gbps de Dell). Si se puede realizar la misma operación utilizando la aplicación de administración del chasis del servidor Blade, utilice mejor dicha aplicación.
Page 101
• Guía de configuración del gabinete del servidor Blade • Dell 8/4Gbps FC SAN Module Administrator’s Guide (Guía del administrador del módulo SAN FC de 8/4 Gbps de Dell) Modificación de la dirección IP del módulo SAN FC De manera predeterminada, la dirección IP del Módulos SAN FC está configurada como 10.77.77.77, con una máscara de subred Ethernet predeterminada de 255.255.255.0.
Page 102
Utilice los siguientes pasos para conectarse y modificar la dirección IP del módulo SAN FC a través de la CLI de la CMC. 1. Establezca una sesión de Telnet a la CLI de la CMC. Guía de introducción del módulo SAN FC de 8/4 Gbps de Dell 53-1001963-01...
Page 103
3. Para habilitar DHCP, seleccione DHCP Enabled (DHCP habilitado) y presione Apply (Aplicar). FIGURA 1 Ficha Setup (Configuración) de la CMC NOTA Consulte la aplicación para obtener más detalles. Guía de introducción del módulo SAN FC de 8/4 Gbps de Dell 53-1001963-01...
Page 104
Repita los subpasos a, b y c con los puertos restantes, según sea necesario. NOTA Utilice sólo SFP aprobados por Dell en los puertos externos de este módulo. 2. Conecte los cables a los transceptores. Los transceptores se adaptan para garantizar una orientación correcta. Si un transceptor no se instala fácilmente, asegúrese de que esté...
Page 105
Módulos SAN FC de recambio. Para obtener instrucciones específicas sobre cómo realizar copias de seguridad de la configuración, consulte la Dell 8/4Gbps FC SAN Module Administrator’s Guide (Guía del administrador del módulo SAN FC de 8/4 Gbps de Dell).
Page 106
2. Agregue la licencia de actualización de puerto utilizando la CLI. 3. Habilite el Módulos SAN FC utilizando la CLI. Cuando esté habilitado el Módulos SAN FC, también se habilitarán los puertos recién agregados. Guía de introducción del módulo SAN FC de 8/4 Gbps de Dell 53-1001963-01...
Apéndice A Notificaciones reglamentarias Para información reglamentaria adicional, consulte la página de inicio sobre el Cumplimiento de normativas reglamentarias de www.dell.com en la siguiente ubicación: www.dell.com/regulatory_compliance. Información de la NOM (sólo para México) La información que se proporciona a continuación aparece en el dispositivo descrito en este documento, en cumplimiento de los requisitos de la...
Page 108
Guía de introducción del módulo SAN FC de 8/4 Gbps de Dell 53-1001963-01...
Page 109
53-1001963-01 1 Ekim 2010 Dell 8/4Gbps FC SAN Module Başlangıç Kılavuzu 53-1001963-01 *53-1001963-01*...
Page 110
Bu belgede kullanılmış olabilecek diğer ticari markalar ve ticari adlar ilgili marka ve adların sahibi olan tüzel kişiliklere veya ürünlerine işaret eder. Dell Inc. kendisine ait olanlar dışında hiçbir ticari marka ve ticari ada ilişkin sahiplik iddiasında bulunmaz. Düzenleme Model Kodları: M5424-n Dell 8/4Gbps FC SAN Module Başlangıç...
Ek A ..........116 Genel Bakış Bu kılavuz deneyimli yükleyicilere bir Dell 8/4Gbps FC SAN Module’ü hızlı şekilde ambalajdan çıkarma, yükleme ve yapılandırmada yardımcı olmak üzere genel bakış sağlamak için tasarlanmıştır. Ayrıntılı yükleme ve yapılandırma yönergeleri için bkz.
Page 112
Ayrıca ek bağlantı noktaları etkinleştirmek ve FC SAN Module’e CLI ile bağlamak için de adımlar sağlanmıştır. Bu yayında, FC SAN Module Komut Satırı Arayüzü’nün (CLI) kullanıldığı yordamlar verilmektedir. Ayrıntılar için Dell 8/4Gbps FC SAN Module Yönetici Kılavuzu’na bakın. Blade Server kasa yönetimi uygulaması kullanılarak aynı işlem yapılabiliyorsa, o uygulamayı kullanın. Gerekli öğeler FC SAN Module’ü...
Page 113
COM Bağlantı Noktası Özellikleri penceresinden, aşağıdaki yapılandırma değerlerini seçin: • Bits per second: 9600 (Bit/saniye: 9600) • Databits: 8 (Databit: 8) • Parity: None (Eşlik: Yok) • Stop bits: 1 (Durak bitleri: 1) • Flow Control: None (Akış Denetimi: Yok) Dell 8/4Gbps FC SAN Module Başlangıç Kılavuzu 53-1001963-01...
Page 114
3. Oturum isteminde, varsayılan kullanıcı adını olarak “admin”, parola olarak “password” sözcüğünü girin. 4. Seçili FC SAN modülünün IP adresini değiştirmek için ilgili CLI komutlarını kullanın. Blade Server Enclosure CLI belgelerinize bakın. Dell 8/4Gbps FC SAN Module Başlangıç Kılavuzu 53-1001963-01...
Page 115
Denetleyicisi (CMC) ile uzaktaki bir yönetim iş istasyonuna bir Ethernet bağlantısı oluşturabilirsiniz. Yönetim iş istasyonu CMC ile aynı Ethernet alt ağında olmalıdır. Yapılandırma tamamlanana kadar FC SAN Module’ün başka bir bağlantıdan değiştirilmediğinden emin olun. Dell 8/4Gbps FC SAN Module Başlangıç Kılavuzu 53-1001963-01...
Page 116
Geri kalan alıcı vericiler için adımları gerektiği gibi tekrarlayın. 3. Tüm bileşenlerin işlediğini doğrulamak için LED’leri kontrol edin. LED düzenleri hakkında bilgi için bkz. “FC SAN Module’ü Çalıştırma” bölümü, Dell 8/4Gbps FC SAN Module Donanım Referans Kılavuzu. 4. İş istasyonundan switchShow komutunu yazarak FC SAN Module’ün doğru çalıştığını doğrulayın.
Page 117
1. FC SAN Module’ü devre dışı bırakın. 2. CLI’yi kullanarak bağlantı noktası yükseltme lisansını ekleyin. 3. CLI’yi kullanarak FC SAN Module’ü devre etkinleştirin. FC SAN Module etkinleştirildiğinde, yeni eklenen bağlantı noktaları da etkinleştirilir. Dell 8/4Gbps FC SAN Module Başlangıç Kılavuzu 53-1001963-01...
Page 118
Ek A Düzenleme Bildirimleri Ek düzenleme bilgileri için on www.dell.com adresinde aşağıdaki konumdaki Düzenleme Uyumluluğu Ana Sayfası’na bakın: www.dell.com/regulatory_compliance. Información de la NOM (sólo para México) La información que se proporciona a continuación aparece en el dispositivo descrito en este documento, en cumplimiento de los requisitos...
Page 119
A נספח הודעות תקינה : בכתובת הבאהwww.dell.com לקבלת מידע תקינה נוסף, עיין בדף הבית של תאימות התקינה באתר www.dell.com/regulatory_compliance Información de la NOM (sólo para México) La información que se proporciona a continuación aparece en el dispositivo descrito en este documento, en cumplimiento...
Page 120
חלופי במידת הצורך. אנו ממליצים לגבות את התצורה באופן קבוע, כדי להבטיח שהתצורה המלאה תהיה זמינה . חלופיFC SAN Module להורדה עבור . Dell 8/4Gbps FC SAN Module לקבלת הוראות ספציפיות לגיבוי התצורה, עיין ב מדריך למנהל של הפעלת יציאות נוספות...
Page 121
- וb , a חזור על שלבים הערה . Dell המאושרים על-ידיSFPs -ביציאות החיצוניות של מודול זה השתמש רק ב .חבר את הכבלים למקמ"שים המקמ"שים מסומנים כדי להבטיח כיוון כהלכה. אם מקמ"ש אינו מותקן בקלות, ודא שהוא מכוון כהלכה ושכיסויי...
Page 122
.( )החלApply )שער( כנדרש ולאחר מכן לחץ על .()החל Apply )מאופשר( ולחץ עלDHCP Enabled , בחרDHCP כדי לאפשר CMC - )הגדרה( של הSetup איור 1 הכרטיסייה הערה .לפרטים נוספים, עיין ביישום מדריך תחילת עבודה Dell 8/4Gbps FC SAN Module 53-1001963-01...
Page 123
B1 שמותקן בתאFC SAN Module עבורSwitch-3 • B2 שמותקן בתאFC SAN Module עבורSwitch-4 C1 שמותקן בתאFC SAN Module עבורSwitch-5 • C2 שמותקן בתאFC SAN Module עבורSwitch-6 • מדריך תחילת עבודה Dell 8/4Gbps FC SAN Module 53-1001963-01...
Page 124
Communications <- ( )עזריםAccessories <- ( )תוכניותPrograms )התחל( ובחרStart לחץ על .()תקשורת .)היפר-מסוף( והזן שם עבור החיבור Hyperterminal בחר COM )התחבר( ובחר יציאתConnect )היפר-מסוף(, לחץ על התפריט הנפתחHyperterminal בחלון .זמינה .()אישור OK לחץ על מדריך תחילת עבודה Dell 8/4Gbps FC SAN Module 53-1001963-01...
Page 125
. לפרטים, עיין ב מדריךFC SAN Module ( שלCLI) פרסום זה מספק הליכים המשתמשים בממשק שורת פקודה . אם ניתן לבצע את אותה פעולה באמצעות יישום ניהולDell 8/4Gbps FC SAN Module למנהל מערכת של ., השתמש ביישום זה במקום זאתBlade Server -התושבת של ה...
Page 126
. קייםFC SAN Module של מודול חדש בתא ריק או החלפה של הערה Dell M1000e של מארזC1/C2 - וB1/B2 ( מסוגI/O) מתוכנן לעבוד רק בתאי קלט/פלטFC SAN Module -ה . Blade Server - . הקפד לבצע את דרישות ההתקנה שב מדריך המשתמש לחומרה של מארז הBlade Server ....
Page 127
. Dell Inc -חל איסור מוחלט על העתקה מכל סוג של חומרים אלה ללא הרשאה בכתב מ , PowerEdge , Latitude , OptiPlex , Dimension , Dell Precision , Inspiron , DELL , הלוגוDell :סימנים מסחריים שבשימוש בטקסט זה...
Page 128
53-1001963-01 אוקטובר 2010 ,1 Dell 8/4Gbps FC SAN Module מדריך תחילת עבודה 53-1001963-01 *53-1001963-01*...
Page 130
Printed in the U.S.A. Imprimé aux U.S.A. Gedruckt in den USA. Dicetak di A.S. Impresso nos EUA. Impreso en los EE.UU. A.B.D.'de basılmıştır. w w w. d e l l . c o m | s u p p o r t . d e l l . c o m...
Page 132
Printed in China Imprimé en Chine Gedruckt in China Dicetak di China Impresso na China Impreso en China Çin'de basılmıştır Printed on Recycled Paper w w w. d e l l . c o m | s u p p o r t . d e l l . c o m...
Page 134
Printed in Malaysia Imprimé en Malaisie Gedruckt in Malaysia Dicetak di Malaysia Impresso na Malásia Impreso en Malasia Malezya'da basılmıştır w w w. d e l l . c o m | s u p p o r t . d e l l . c o m...
Page 136
Printed in Brazil Imprimé au Brésil Gedruckt in Brasilien Dicetak di Brasil Impresso no Brasil Impreso en Brasil Brezilya'da basılmıştır w w w. d e l l . c o m | s u p p o r t . d e l l . c o m...
Page 138
Printed in Poland Imprimé en Pologne Gedruckt in Polen Dicetak di Polandia Impresso na Polônia Impreso en Polonia Polonya’da basılmıştır w w w. d e l l . c o m | s u p p o r t . d e l l . c o m...