Preparing the Installation Site

Warning
Warning

Choosing a Site for Installation

Ensuring Overcurrent Protection

Warning
Cisco VG248 Analog Phone Gateway Hardware Installation Guide
2-2
Read the installation instructions before you connect the system to its power
source.
This unit is intended for installation in restricted access areas. A restricted
access area is where access can only be gained by service personnel
through the use of a special tool, lock and key, or other means of security,
and is controlled by the authority responsible for the location.
Install the system in a restricted access area, where access can be gained only
by service personnel through the use of a special tool, lock and key, or other
means of security.
Choose a site with a dry, clean, well-ventilated and air-conditioned area.
Choose a site that maintains an ambient temperature of 32 to 104 ° F (0 to
40° C).
The system relies on the protective devices in the building installation for
protection against short-circuit, overcurrent, and earth (grounding) fault. Ensure
that the protective devices in the building installation are properly rated to protect
the system, and that they comply with national and local codes.
This product relies on the building's installation for short-circuit
(overcurrent) protection. Ensure that a fuse or circuit breaker no larger than
120 VAC, 15A U.S. (240 VAC, 10A international) is used on the phase
conductors (all current-carrying conductors).
Chapter 2
Preparing to Install the VG248
78-13154-01