hit counter script

Pcs Rx - Samsung SGH-X630 Service Manual

Gsm telephone
Hide thumbs Also See for SGH-X630:
Table of Contents

Advertisement

Flow Chart of Troubleshooting

10-2-3. PCS RX

Continuous RX ON
RF Input : 62 CH
AMP : -50dBm
NORMAL CONDITION
Catch the channel ?
YES
F100 Check
Pin #6 ≥ -65dBm ?
YES
F100 Check
Pin #8, 9 ≥ -65dBm ?
YES
UCD100 Check
Pin#10, 11 ≥ -65dBm ?
YES
UCD100 Check
Pin#27 =1.8V ?
YES
UCD100 Check
Pin#34 =Clean 2.8V?
YES
UCD100 Check
Pin#35,36,37,38=100mV?
YES
Check U102
This Document can not be used without Samsung's authorization
NO
NO
NO
NO
NO
NO
NO
UCD100 Check
Pin #21 : 13MHz ?
Vpp : 1.1V?
YES
UCD100
Change or resolder
SAMSUNG Proprietary-Contents may change without notice
Check soldered status of
R700, C703, C701, L703
RFS701, C700
Resolder or Change
F100 Resolder or Change
Check soldered status of
L708, L709, C721
CHECK U102
C706, U102
Check or resolder
OSC700 Check
NO
Pn#1 : Freq =13MHz,
Vpp=1.2V?
YES
UCD100
Check & resolder
10-30
NO
OSC700
Check & resolder

Advertisement