• The voltage and pulse width used are as measured at
pin 10 of the 12-pin multi-connector on the rear
panel.

VD Input Specifications

7 H – 33 H
• Input impedance: 75 Ω or 10 kΩ or more.
• Input amplitude 2.5 to 5.0 Vp-p (for both 75 Ω
termination ON and OFF).
• The voltage and pulse width used are as measured at
pin 7 of the 12-pin multi-connector on the rear panel.

HD Input Specifications

2.0µs – 5.0µs
• Input impedance: 75 Ω or 10 kΩ or more.
• Input amplitude 2.5 to 5.0 Vp-p (for both 75 Ω
termination ON and OFF)
• The voltage and pulse width used are as measured at
pin 6 of the 12-pin multi-connector on the rear panel.

Trigger Pulse Specifications

2µs – 1/4s
• Input impedance: 10 kΩ or more.
• The voltage and pulse width used are measured at pin
11 of the 12-pin multi-connector on the rear panel.
2.5 – 5.0 Vp-p
0 – 0.6V
2.5 – 5.0Vp-p
0 – 0.6V
2.5 – 5.0V
0 – 0.6V