Installing a Replacement MIC
Caution: Before proceeding, make sure you are properly grounded using,
To install a replacement MIC:
Step
Action
1
Carefully remove the replacement MIC
from its anti-static packaging.
2
Install the replacement MIC into the
correct slot.
3
Replace the cover.
4
Attach the MIC fiber connections by
clipping them into the cable receptacles.
5
Power up the system.
6
Make a flash diskette with which you
will flash the MICs.
7
Flash the MICs.
8
Compare the revision levels to other
MICs in your system.
9
On the MIC, make sure that the local
and remote connection fiber status
lights are green.
10
Using Endurance Manager:
• Make sure that any components
affected by this procedure are active
or online. Reenable any faulted or
disabled components
• Make sure that the system rejoins
the Endurance server.
Endurance Server Maintenance
for instance, a wrist strap with an attached alligator clip that is
connected to an appropriate ground.
(page
9-31).
Notes
Ensure that local and remote connections are
cabled correctly. For information about cabling
the MICs, refer to
Table 2-1
Netserver AA Solution Installation
Prepare this from an Endurance distribution
diskette or a subsequent hotfix if applicable.
Refer to
Making an MTC Diskette
for detailed information about creating the flash
diskette.
results in the correct
Mtcflash - f
configuration. If all flash components are up to
date, MTCFLASH does not reprogram the MIC.
Verify that the revision level of the new MIC
matches those of the other three MICS in the
server.
If the connection fiber status lights are not
green, correct the condition and continue.
For a description of the status lights, refer to
MIC LEDs
in
Appendix
in
Chapter 2
of
HP
Guide.
in
Chapter 7
A.
9-17