ProBridge Gateway

User Manual

Advertisement

Table of Contents
loading

Summary of Contents for GE ProBridge

  • Page 1: User Manual

    ProBridge Gateway User Manual...
  • Page 2 Any similarity to names and addresses of actual businesses or persons is entirely coincidental. Trademarks GE and the GE monogram are registered trademarks of General Electric. and patents Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products.
  • Page 3: Table Of Contents

    ProBridge Gateway Table of Contents ABLE OF ONTENTS ................4 REFACE ................5 VERVIEW 1.1 P :......5 RIDGE ATEWAY OMPONENTS 1.1.1 Installation Environment ..........6 1.2 P ..............6 OWER 1.3 P ....7 RIDGE ATEWAY RODUCT IAGRAM 1.3.1 Dipswitch Position Legend ...........8 ............8 ROGRAMMING .............9...
  • Page 4: Preface

    GE Security ProBridge Gateway REFACE This document includes an overview of the product and detailed instructions explaining how to install and operate the unit. There is also information describing how to contact technical support if you have questions or concerns.
  • Page 5: Overview

    DVMRe 5, camera input 14 can be mapped to dome address number 983. In the Operating mode the ProBridge Gateway will translate messages to ensure that telemetry messages originating from DVMRe products will correctly address the intended dome.
  • Page 6: Installation Environment

    OWER The ProBridge is furnished with a power supply (110 or 240 VAC). Do not use any other power supply with this product. The manufacturer accepts no responsibility for damage caused by the use of any other power supply.
  • Page 7: Pro Bridge Gateway Product Diagram

    ProBridge Gateway GE Security 4310-0008: 220VAC Power Supply Power Supply Input Voltage: 220 Volt AC Tolerance: ±10% Frequency: 50 Hz Power Supply Output Voltage: 12 Volt DC Current: 110mA Power: 1.3 Watts Connector: 2.1mm female barrel. Center Positive RIDGE ATEWAY...
  • Page 8: Dipswitch Position Legend

    (File/Properties, “Connect to” tab, “Configure” button) Set local echo on (File/Properties, “Settings” tab, “ASCII Setup” button) • Cycle power on the ProBridge Gateway box and follow the instructions in HyperTerminal. Connection Diagram for programming mode is shown below 0150-0265C / April 2006...
  • Page 9: Operating Mode

    • Connect the devices and cables as shown below. • Cycle power on the ProBridge Gateway box and the other devices. Connection Diagram for Operating mode is shown below. KB3 Protocol menu item must be set to YES. 0150-0265C / April 2006...
  • Page 10: Operation

    Pin 3: Green/White Pin 2: Orange Pin 2: Orange Cable Required: 5 Foot, RJ-45-to-RJ-45 Pin 1: Orange/White Pin 1: Orange/White RJ-45 RJ-45 Triplex RS485 Cable (Supplied). Connector Connector Connects ProBridge to DVMRe-CT. RJ-45 Connector RJ-45 Connector 0150-0265C / April 2006...
  • Page 11: Pro Bridge To Pc Cable

    Cable Required: 6 Foot RJ-45 to DB9F Pin 4 Pin 4 Pin 3 Pin 3 RS232 Cable (Supplied). Connects Pin 2 Pin 2 ProBridge to the serial port of a PC. Pin 1 Pin 1 RJ-45 DB-9F NOTE: This cable is used for Programming Connector Connector...
  • Page 12: Specifications

    DC jack, positive center. Power Supply Voltage: 12 VDC Current: 110 mA Power: 1.5 W Note: All specifications are subject to change without notice. GE believes that all specifications are correct, however no liability is assumed for omissions or errors.
  • Page 13: Contacting Technical Support

    Note: Be ready at the equipment before calling for technical support. Online publication library Another great resource for assistance with your GE product is our online publication library. To access the library, go to our website at the following location: http://www.gesecurity.com...