hit counter script
Kenmore 41798076701 Installation Instructions Manual
Kenmore 41798076701 Installation Instructions Manual

Kenmore 41798076701 Installation Instructions Manual

Electric & gas dryer
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

®
Installation
instructions
I
[]
|
[]
CC|
tal ci
f
para la
PIN 134941300B
(0804)
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
www.sears.com

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Kenmore 41798076701

  • Page 1 ® Installation instructions para la tal ci PIN 134941300B (0804) Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com...
  • Page 2: Table Of Contents

    CONTENTS Pre-lnstallation Requirements ............................Electrical Requirements ..............................Exhaust System Requirements ............................Gas Supply Requirements ............................Location of Your Dryer ..............................Rough-In Dimensions ..............................Mobile Home Installation ............................... Unpacking ................................... Reversing Door Swing ..............................Electrical Installation ..............................Grounding Requirements .............................. Electrical Connections--3-wire ............................
  • Page 3: Electrical Requirements

    EXHAUST SYSTEM REQUIREMENTS ELECTRICAL REQUIREMENTS Use only 4 inch (10.2 cm) diameter (minimum) rigid or flexible ELECTRICDryer metal duct and approved vent hood which has a swing-out damper(s) that open when the dryer is in operation. When the CIRCUIT- individual 30 amp. branch circuit fused with 30 dryer stops, the dampers automatically close to prevent drafts amp.
  • Page 4: Gas Supply Requirements

    Do not allow combustible materials (for Connect an inclined or digital manometer between the example: clothing, draperies/curtains, paper) to come in dryer and the point the exhaust connects to the dryer. contact with exhaust system. The dryer MUST NOT be Set the dryer timer and temperature to air fluff (cool exhausted into a chimney, a wall, a ceiling, or any concealed down) and start the dryer.
  • Page 5: Location Of Your Dryer

    5. A 1/8inch(0.32 cm)N.RT. plugged t apping, a ccessible fortestgauge connection, MUSTbe installed immediately upstream of the gas supply connection to the dryer. 6. The dryer MUSTbe disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1/2 psig (3.45 kPa).
  • Page 6: Rough-In Dimensions

    Dryer Installation Dimensions Free-Standing & Under Counter Electrical supply 48.5" To clear open door on rear of unit (123.19cm) 0 o,_ i ..Gas supply pipe 36" on rear of unit (91.44cm) s.T', (5. 72cm) __!__,.___ 2.25 _ 5.0" (12.7cm) Center line height rear, right, left (34.29cm)
  • Page 7: Mobile Home Installation

    UNPACKING MOBILE HOME INSTALLATION Using the four shipping carton corner posts (two on each side), carefully lay the dryer on its left side and remove the foam 1. Dryer MUSTbe exhausted outside (outdoors, not beneath the shipping base. mobile home) using metal ducting that will not support combustion.
  • Page 8 Door Reversal Instructions Figure 1 Figure 4 1. Open door and remove four (4) plugs in the door opening 5. Remove two (2) door handle screws and two (2) plastic hole opposite the hinges. Retain all parts for use later unless plugs from door, again taking care not to scratch paint on otherwise noted (Figure 1).
  • Page 9 11. Reassemble lens to transition ring with holes to install handle on right-hand side of door assembly. For proper fit, insure the retention tabs on transition ring are on top of lens and lens handle holes are aligned with holes in transition ring. Figure 7 8.
  • Page 10: Electrical Installation

    ELECTRICAL INSTALLATION Canadian ELECTR/CDryer Improper connection of the equipment grounding ELECTR/CDryer conductor can result in a risk of electrical shock. Check with a The following are specific requirements licensed electrician if you are in doubt asto whether the appliance proper and safe electrical installation of your dryer.
  • Page 11: Electrical Connections--3-Wire

    ELECTRICALCONNECTIONS ELECTRICAL CONNECTIONS FOR 4-WIRE SYSTEM FOR 3- WIRE SYSTEM USA ELECTRICDryer USA ELECTRICDryer 1. Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of 1. Remove the screws securing the terminal block access the dryer upper corner.
  • Page 12: Gas Connection

    GAS CONNECTION 7. Place these instructions in a location near the dryer for future reference. Remove the shipping cap from gas pipe at the rear of the dryer. 8. To stack your dryer on a compatible washer call your local dealer or call the Toll Free number 1-800-4-MY-Home 800-469-4663) to find your local distributor to purchase...
  • Page 13: Espahol

    Tabla de Materias Requenmientos de instalaci6n preliminares ........................Requenmientos el_ctricos ............................... Requenmientos del sistema de escape ......................... 14-16 Requerimientos del suministro de gas..........................Ubicaci6n de su secadora .............................. Dimensiones para la instalaci6n ............................. Instalaci6n en casas m6viles ............................Desembalaje ................................Puerta reversible ................................
  • Page 14: Requenmientos Del Sistema De Escape

    REQUERIMIENTOS DE INSTALA CION 5ecadorasa GAS PRELIMINARES CiRCUITO- Circuito individual derivado de 15 amp, con fusibles Herramientas y materiales necesarios para la instalacion: de 15 amp. de retardo m_qximoo disyuntor. 1. Destornillador Phillips ALIMENTACION ELE-CTRICA- Corriente alterna, monof_isica, 2. Pinzas universales 60 Hz, 120 voltios, trifilar.
  • Page 15 _Riesgo de incendio- Lasecadora debe set ventilada al exterior Use una tapa de salida adecuada para el extreme del ducto que salga al exterior de la vivienda y selle todas las juntas con cinta de la vivienda. No ventile la secadora a una chimenea pared, techo, adhesiva para ductos.
  • Page 16: Requerimientos Del Suministro De Gas

    UBICACION DELESCAPE DESPEJES MJNIMOS DE INSTALA CION - Todaslassecadorasvienen de f_ibrica equipadas con escape trasero. Sin embargo, Pulgadas (cm) en las secadoras el_ctricas, el escape puede hacerse al lade derecho o izquierdo Parte Parte Parte del gabinete o en la parte inferior de la secadora. En lassecadoras a gas, el escape Delantera Lades Trasera...
  • Page 17: Dimensiones Para La Instalaci6N

    Dimensiones de la Insta/acion Fuente electrica en la parte 48.5" En el claro abra la puetra posterior de la unidad (123.19cm) =_,_ EJ tubo de la fuente gas en la parte 36" posterior de la unidad (91.44cm) (5.72cm) /" IT",..
  • Page 18: Instalaci6N En Casas M6Viles

    INSTALA CION EN CASAS MO VILES MODEL OS A UTONOMOS CON CONSOLA SUPERIOR DIMENSIONES PARA LA INSTALA CION El tubo de escape de la secadora DEBE ser instalado DESEMBALAJE hacia el exterior (El escape debe colocarse en la parte exterior y no debajo de la casa m6vil.) Debe usarse 1.
  • Page 19: Puerta Reversible

    Instrucciones para la inversion de la Figura 1 Figura 1. Abra la puerta y quite los cuatro (4) tapones situados en la 5. Quite los dos (2) tornillos de la manija de la puerta y los dos abertura de la puerta, en el lado opuesto a las bisagras. A (2) tapones pl_qsticosde la puerta, teniendo cuidado una vez menos que se indique Io contrario, conserve todas las piezas m_qs de no rasgunar la pintura de la puerta (figura 4).
  • Page 20 Figura 11 12. Vuelva a instalar el conjunto exterior de la puerta exterior en el conjunto interior de la puerta (figura 11). 13. Instale los cuatro (4) tornillos que sujetan la bisagra al Figura 8 conjunto de la puerta en la nueva ubicaciOn, teniendo en 9.
  • Page 21: Instalaci6N El@Ctrica

    INSTALA CION ELECTRICA Para una secadora conectada permanentemente: 1. La secadora DEBE ser conectada a un sistema de cableado S odo,o, EZfCrRICAS met_qlicopermanente, puesto a tierra; o se debe instalar un conductor de puesta atierra deequipojuntocon Iosconductores Los siguientes requerimientos del circuito y conectarse al borne de puesta a tierra del equipo especificos para el funcionamiento correcto y seguro de su...
  • Page 22: Conexi6Nes El@Ctricas- Trifilares

    CONEXIONES ELE-CTRICAS PARA CONEXIONES ELE-CTRICAS PARA UN SISTEMA TETRAFILAR UN SISTEMA TRIFILAR Secadoras ELECTR/CAS No Canadienses Secadoras ELECTR/CASNo Canadienses 1. Saque los tornillos que sujetan la cubierta de acceso al las Saque los tornillos que sujetan la cubierta de acceso del tablero terminales y el soporte de montaje del anclaje del cordon, de terminales y el soporte de montaje del anclaje de cablesituado situado en la esquina superior de la parte trasera de la...
  • Page 23: Instalaci6N

    CONEXION DEL GAS Si su secadora no funciona, consulte la secci0n "Lista de Control de Averias" que se encuentra en su Manual del 1. Saque la tapa de embarque de la tuberia de gas de la secadora Usuario, antes de llamar para obtener servicio. situada en la parte trasera.
  • Page 24 Notes...

Table of Contents