  • Page 1 Installation Instructions 42"Island Vent Hood Model: ZV1050 Monogram°...
  • Page 2 Design Information BEFORE YOU BEGIN WARNING: TO REDUCE THE RISK OF HRE, ELECTRICAL Read these instructions completely carefully. SHOCK OR INJURY TO PERSONS, OBSERVE THE " IMPORTANT - S.vethese instructions for FOLLOWING: local inspector's use. A. Use tiffs unit only in the manner intended by the •...
  • Page 3: Table Of Contents

    Design Information CONTENTS Design Information Step 3, Check Insudlation Hardware ......Product Dimensions ............Step 4, Mount Template ..........Duct Cover Accessories ..........3, 4 Step 5, Install Support Frame ........Determine Installation Height ........Step 6, Secure Wiring ............. Advance Planning Step 7, Size and Install...
  • Page 4: Design Information

    25-1/2"to30" ZX10510SFSS 9'6" 25-1/2"to30" DUCT COVER DIMENSIONS ZX10510SFSS 9'7" 25-1/2"to30" ZX10510SFSS 9'8" 25-1/2"to30" ZX10510SFSS 9'9" 25-1/2"to30" ZX10510SFSS 9'10" 25-1/2"to 30" ZVl050 Duct CoverDimensions ZX10510SFSS 9'11" 25-1/2"to 30" ZX10510SFSS 10'0" 25-1/2"to 30" ZV1050 11-1/2" 12" ZX1059 19" 20" ZX10510 25" 26"...
  • Page 5: Advance Planning

    Advance Planning POWER SUPPLY TOOLS AND MATERIALS REQUIRED (not supplied) IMPORTANT • Tapemeasure - Please read carefully. • Knife WARNING: , ORP ON • Spirit level • Wire cutter THIS APPLIANCE MUST BE PROPERLY GROUNDED. • Wire stripper • Wire nuts ATTENTION •...
  • Page 6 Advance Plannin Total Equivalent Quantity Equivalent Duct Piece Dimensions Length* Used Length Round, (per toot straight length) (per toot 3-1/4" x 12" this chart to compute maximum length) straight permissible lengths duct runs otltdooI's. 90 ° elboB 17 ft. Note: Do not exceed maximum ?ermissible equivalent lengths! 45 °...
  • Page 7 Installation Instructions [STEP 1 ] CONSTRUCT CEILING SUPPORT Ceiling Plan the location Hood Determine the exact location of the vent hood. Centerline • Use a plumb bob to check location to be sure countertop/cooktop location below the hood will align exactly.
  • Page 8: Installation Instructions

    Installation Instructions [STEP 1 ] CONSTRUCT CEILING SUPPORT (cont.) EXAMPLE B 16"Joist Spacing 11-1/4"InstallCross-Framing Symmetrically About 2x4 Cross \ Framing Align Ductto Cooktop Outline Centerof Cooktop Front of Hood TopView--Ceiling Joists RunPerpendicular t o Frontof Hood EXAMPLE C 2x4Cross 11-1/4"Install Framing Cross-Framing Symmetrically A bout...
  • Page 9 Installation Instructions 2x 4 Min. I STEP 11CONTINUED CrossFraming ..• Arrange cross flaming in the ceiling to suit the existing suuculre. See examples. - Secure each 2 x 4 block with at least four (4), #10 wood screws, 3" long (not supplied). Use 8 wood screws total for the two supports.
  • Page 10 Installation Instructions ISTEP 21 REMOVE THE PACKAGING The vent hood is packed separately flom the decorative duct cover or accessory covers ZX1059SFSS or ZX10510SFSS. • Remove the flame, cover, parts box and packaging. • Remove junction box cover. • Install suain relief onto junction box coveL [STEP 3 CHECK INSTALLATION HARDWARE...
  • Page 11: Step 4, Mount

    Installation Instructions ISTEP 4 ] MOUNT TEMPLATE • Align the template with tile marks on tile ceiling and rope in place. - Be sure tile template is oriented correctly, with tile flont of tile hood. • Use a phnnb bob to be sure the mounting holes will provide parallel alignment with tile countertop...
  • Page 12: Step 5, Install

    Installation Instructions [STEP 6 SECURE WIRING STEP 7 SIZE AND INSTALL DUCTWORK • Route house wiring through the ceiling hole and pull a length to reach the hood junction box, approximately 6" below the support. Ceiling Celing House Duct ..LeftSide View :L[__...
  • Page 13: Step 8, Install

    Installation Instructions I STEP 81 INSTALL DECORATIVE DUCT COVERS InstallScrewon EachSide Pretap BottomDuctCover 2 Screw BottomDuct Holes Cover (One Each Side) Top Duct Cover Stop _ Install Stop Screw Screw in Hole of Upper (Inner) Duct Cover \... • Slide the lower decorative duct over the installed •...
  • Page 14: Step 9, Install

    Decorative to use UL approved anti-oxidant compound Screw aluminum-to-copper connectors. AVERTISSEM ENT : si l ec ,bl ,ge de la maison n'est pas du type f, deux ills avec un fil de terre, l'installateur dolt fournir un circuit de terre.
  • Page 15 Installation Instructions STEP 12 INSTALL FILTERS, FINALIZE INSTALLATION FilterSlots • Remove protective film on tile filters. • Tip tile filter into tile lower slots at tile rear of tile opening. I,ift tile filter and pull tlle knob forward until tile filter rests on tlle slots.
  • Page 16 Note: Prod improvement is a conthluhlg endeavor (;enera] Electric. Therefbre, materials, appearance specifications are subject to change _ithout notice. Monogram: GEConsumer & Industrial Pub.No.49-80153-2 GEAppliances General Electric" Company 11-07 JR Louisville, KY 40225 ge.com Printed in Italy @2007 GE Company...