Recommended: PC or Notebook to Access the Internet Camera......3 FEATURES AND BENEFITS ....................4 PHYSICAL DESCRIPTION....................5 .........................5 RONT ANEL ...........................6 ANEL ........................7 OTTOM ANEL UNPACKING THE DCS-1000 .....................8 DCS-1000 ............8 ONNECTING TO THE AMERA TAND HARDWARE INSTALLATION..................9 SECURITY..........................10 SOFTWARE INSTALLATIO N ..................11 ......................11 ONFIGURATION ......................12...
Page 3
IP A ...................38 OW TO HANGE DDRESS Change IP Address......................38 ....................40 OW TO DD A AMERA Add Camera ........................40 ....................43 OW TO ELETE A AMERA Delete Camera ........................43 ....................44 OW TO IEW A AMERA View Camera ........................44 ..................45 OW TO NAP SHOT A AMERA Snap shot Camera ......................45...
IPView application. Introduction Thank you for the purchase of DCS-1000 connecting directly to an Ethernet or Fast Ethernet. It is different from the conventional PC Camera, DCS-1000 is a standalone system with built-in CPU and web-based solutions providing a low cost solution that can transmit high quality video images for monitoring.
Web Configuration Applying a standard web browser, administrator can configure and manage DCS-1000 directly from its own web page via the Intranet or Internet. Up to 64 users name and password are permitted with privilege setting controlled by the administrator.
Power LED Manual Focus Ring Power LED The Power LED is positioned on the right side of DCS-1000’s lens while facing DCS-1000.Steady blue confirms DCS-1000 is powered on. Note: There are three settings for the Power LED to control the light illumination for...
Configuration section for detailed information and usage. LAN LED The LAN LED is positioned on the far right side of the DCS-1000’s lens while facing DCS-1000. It is located right of the Power LED. Steady orange confirms good connection to LAN connectivity.
Bottom Panel Screw Hole Screw Hole Located on the bottom panel of DCS-1000 the screw hole is used to connect the camera stand onto DCS-1000 by attaching the screw head on the camera stand into the screw hole of DCS-1000.
DCS-1000 comes with a camera stand with a swivel ball screw head that can be attached to DCS-1000's bottom screw hole. Attach the camera stand to DCS-1000 and station it for your application. There are three holes located in the base of the camera stand allowing the DCS-1000 to be mounted on the ceiling or any wall securely.
Hardware Installation This section describes the Hardware installation procedure for DCS-1000. 1. Connect an Ethernet cable Connect an Ethernet cable to the network cable connector located on DCS-1000’s rear panel and attach it to the network. 2. Attach the external power supply...
"User Name" and "User Password" which is assigned by the Administrator. Administrator can release a public user name and password so when remote users access DCS-1000 they will have the right to view the image transmitted by DCS-1000. Note: When DCS-1000 is used for the first time it is highly recommended the Administrator sets the "Admin ID"...
From the web browser enter the default IP address to access the Home screen of DCS-1000 to configure your DCS-1000 type “http ://192.168.0.20” in the address box. The number is the default IP address of your DCS-1000. Press Enter Note: The PC’s IP address must correspond with the DCS-1000’s IP address in the...
Main Menu Image After the default IP address is entered from the browser DCS-1000 Home screen will appear with a still image. There will be three options to choose from to set-up and view your DCS-1000 and they are as follows: View Image –...
System Administration - System The System menu contains commands for settings that are required for inputting key details to set-up DCS-1000 for operation. Click on "System" in the system admin istration menu bar and the System screen will appear as illustrated below: Click on “Home”...
Page 15
IP Assignment Important Information Access to DCS-1000 is done through assigning a proper IP address. Please make sure to use a vacant IP address when you assign the IP address for DCS- 1000. This will prevent errors from occurring if the IP address is overlapped.
Page 16
“PPPoE” option and enter the Service Name, User ID and Password into the respective fields. DCS-1000 will get an IP address from the ISP each time DCS-1000 starts up. DNS IP Address: DNS (Domain Name System) server is an Internet service that translates domain names (ie.
Page 17
DNS server. Open Second Port: The Web Server field allows settings to open a second port for DCS-1000. This will permit users IP Sharing Gateways to support multiple DCS-1000s. By default Port 80 is always opened for DCS-1000 Web Server access. Select “Yes”...
Page 18
Port 84 map to 192.168.0.104 Port 85 map to 192.168.0.105 The Transfer Image field allows settings to open a second port for DCS-1000 to transfer images. The default Port 8481 is open image transfer and you can define a second port similar to the above.
System Administration - Image Image menu in the system administration contains commands to provide the settings for the images captured by DCS-1000. Click on “Image” in the system administration menu bar and the Image screen will appear as illustrated below: Click on “Home”...
50 Hz or 60 Hz (default). Note: 50 Hz and 60 Hz variants are available to accommodate the different light frequency found in USA (60 Hz) and Europe (50 Hz) for the DCS-1000 to ensure better image quality. Save/Cancel: After making sure all settings in the Image are correct, click on the “Save”...
Page 21
User Name is “Guest” and the User Password is “Guest” anyone can access DCS-1000 with these details used as a group of users under the User Name Guest. The maximum length for the User Name is 12 (Printable ASCII).
System Administration – DateTime The DateTime menu contains commands for setting DCS-1000's time and date requirements to provide correct information to users who might be thousands of miles away in the remote site. There are two options to select from the DateTime menu bar either Synchronized with Time Server or Set Manually.
Page 23
Note 2: When you select Set Manually, each time DCS-1000 is powered off and on you must re-enter the details once again due to time lost. Save/Cancel: After making sure all settings in the DateTime are correct, click on the “Save”...
The Trigger menu contains commands for the I/O Trigger connectors providing the physical interface for 2 digital output and 2 digital input that is used for connecting a diversity of external alarm devices to DCS-1000 such as IR-Sensor and alarm relay.
Page 25
Output 1 time and Output 2 time in seconds. Save/Cancel: After making sure all settings in the System are correct, click on the “Save” icon to store the settings for the DCS-1000. You can alternatively click on the...
Page 26
When connecting other devices through the I/O connectors, please make sure the maximum current of 100mA is strictly observed. Any failure to do so might cause a loss of power to DCS-1000 and possibly cause serious damage to the Network Camera.
Home Screen Reset: The Reset command restarts DCS-1000 just like turning the device off and on and saved settings are retained. The Reset panel contains the message “Do you really want to reset this device?” and a YES button. If you do not want to reset DCS-1000, exit the panel without clicking YES, otherwise, click on the “YES”...
Factory Reset: A factory reset restarts DCS-1000 and returns all of its settings to their default values. The Factory Reset panel contains the message “Do you really want to factory reset this device?” and a YES button. If you do not want to carry out a factory reset command, exit the panel without clicking YES, otherwise click on the “YES”...
Page 29
(Output 1 trigger or Output 2 trigger). Note 1: Output trigger will send a 5V signal to the device connected to the DCS-1000. A maximum of two devices is permitted to connect to DCS-1000 to utilize the output trigger function.
(Output 1 trigger or Output 2 trigger). Note 1: Output trigger will send a 5V signal to the device connected to DCS-1000. A maximum of two devices is permitted to connect to DCS-1000 to utilize the output trigger function.
IPView Application Installation Installation Insert the CD-ROM into the CD-ROM drive to initiate the auto-run program. Once completed a menu screen will appear as follows: To install the IPView Application click on the "IPView" button to activate the installation procedure for the application program. Once executed a prompt will appear requesting the input of the desired language selection.
Page 32
The Welcome screen will appear. Click on the “Next” button to proceed with the installation. The License Agreement prompt will appear as below. Read the details carefully and click on the “Yes” icon to continue with the installation procedure.
Page 33
A prompt will appear and in the Destination Location dialog box, you may click on “Next” to accept the recommended destination location or click on “Browse” to select another location. After specifying the desired destination location, click on “Next” to proceed further. The Select Program Folder prompt will appear providing information of where the IPView application will be located, click on “Next”...
Page 34
or click on the “Finish” icon to complete the installation procedure After successfully installing the IPView, the application program for DCS- 1000 is automatically installed to \Programs\Files Directory. start running IPView click windows Start Menu/Programs/IPView/IPView...
Page 35
Once IPView is executed a Login prompt will appear, you must enter the default User Name: “admin” into the respective field and click on “OK” to log into the application. Once login, the IPView application is executed and the IPView interface will appear as follows in the default List View format:...
IPView – Getting Started This section describes the operation of the IPView application User Interface with detailed procedures for using the application. IPView IPView is responsible for the management of preview, configuration, and searching of each camera. It is designed with a user-friendly interface for ease of control and navigation requirements as illustrated below.
List view format How to Change Password Change Password When IPView is used for the first time it is highly recommended to change the User Name and Password by the Administrator to constrain users access to the IPView application. Once the User Name and Password are defined only the Administrator has access to the management of IPView applications.
Page 38
To change the User Name and Password select “Tools” > “Options”. The Options dialog box will appear as illustrated below. The administrator needs to enter a User Name , Password and Confirm password into the respective fields. Once all the new details are entered click on the “OK”...
How to Change IP Address Change IP Address To change an IP Address for a camera select “Camera” > “Add”. An Add Camera dialog box will appear as illustrated below. Click on the “Browse” icon, the Browse Camera dialog box will appear with a blank screen as illustrated below.
Page 40
You must highlight the camera you wish to change the IP Address and click on the “Change IP” icon and the Change IP Address dialog box will appear as depicted below: Enter the new IP Address along with the Subnet Mask and Default gateway into the respective fields and click on the “OK”...
How to Add a Camera Add Camera To add a new camera select “Camera” > “Add”. An Add Camera dialog box will appear as illustrated below. You can enter the IP Address of the camera in the specified field and click the “Add”...
Page 42
Click on the “Search” icon and IPView will detect and search all the available camera’s that are installed on the local area network as depicted below: You must highlight the camera you wish to add and click on the “Add” icon. The Add Camera dialog box will appear once again with the IP Address entered.
Page 43
If the Login Camera dialog box appears make sure to enter the correct User Name and Password and click on the “OK” icon and the camera will be added into IPView in list format. If the User Name and Password is entered incorrectly the camera will not be added into IPView.
How to Delete a Camera Delete Camera To delete a camera you must highlight the camera y ou wish to delete from IPView list view format. From the menu bar select “Camera” > “Delete”. A Delete Camera dialog box will appear and click on the “Yes” icon to delete the camera or click on “No”...
How to View a Camera View Camera From the menu bar select “View” > “4 Cameras” (other choices are available in 1 Camera, 9 Cameras and 16 Cameras viewing format) and the viewing screen will appear with the video image. Note: The icon on the upper left corner of the screen will appear with the camera number that is being displayed...
How to Snap shot a Camera Snap shot Camera To snap shot a camera you must highlight the camera you wish to snap shot from the list view format. From the menu bar select “Camera” > “Snap shot”. A Save Image dialog box will appear for you to save the snap shot picture.
Page 47
IP Assignment There are two options to select from the IP Assignment either Manually Assign or Assign Automatically Using. Please refer to the Web Configuration section under “System Administration – System” for further details. DNS (Domain Name System) server is an Internet service that translates domain names into IP addresses.
Page 48
Wireless (Please skip this section if your camera is not wireless) Allows setting for connection mode, network name, wireless channel, and WEP key. Please refer to the Web Configuration section under “System Administration – System” for further details. Misc Allows setting for LED Control, ActiveX control location, and second port. Please refer Configuration...
Page 49
Image Image provides the settings for the video image of the camera such as brightness, contrast, hue, resolution, compression, frame rate, and light freq. Please refer Configuration section under “System Administration – Image” for further details. Users Contain commands to allow system administrator to assign legal users who are permitted to monitor the camera from the remote site by Add or Delete user.
Page 50
To add a user click on the “Add” icon and the Add User dialog box will appear. Enter the User Name and Password into the specific field. Select the I/O Output Control to give users the privilege of accessing the I/O Output Control.
Page 51
Trigger 1 Contains commands for setting the I/O Trigger connectors providing the physical interface for 1 digital output and 1 digital input that is used for connecting a diversity of external alarm devices to the camera such as IR- Sensor and alarm relay. Please refer to the Web Configuration section under “System Administration –...
Page 52
Trigger 2 Contains commands for setting the I/O Trigger connectors providing the physical interface for 1 digital output and 1 digital input that is used for connecting a diversity of external alarm devices to the camera such as IR- Sensor and alarm relay. Please refer to the Web Configuration section under “System Administration –...
Page 53
Tools Contains commands to reset the camera and update firmware (please refer to the appendix for detailed information). Please refer to the Web Configuration section under “System Administration – Tools” for further details on reset. Make sure to save any changes you have made to keep the information updated.
Note: Alternatively you can click the Property icon as illustrated or use the hot key “F2”. Menu Bar The menu bar provides easier access for users to navigate the IPView with different selections along with hot key capabilities as follows: Menu Bar - File “File”...
Columns When “Columns” is launched a dialog box will appear allowing the option to choose the columns one would like to display in List View as illustrated below. Viewing Format You can view the format in “List” view. The “List” viewing format allows easy management and control of each camera.
Note: Right click the mouse pad on any kind of the camera will bring up a context sensitive menu which shows the actions you can apply to the selected camera. Double click on the desired camera will bring up the Property dialog box. To update camera list view just click on the “Refresh”...
Enable Function By default the video image is enabled. There will be a “check” next to the Enable command to show that the Enable function is working. To disable real-time image select “Camera” > “Enable” and real-time video image will stop and shutdown.
IPView Icon Description Open a new file. Alternatively the hot key is Ctrl+N. Open an existing file. Alternatively the hot key is Ctrl+O. Save a file. Alternatively the hot key is Ctrl+S. List view format. Alternatively the hot key is Ctrl+F1. 1 Camera view format.
Context Sensitive Menu In list view format by highlighting a camera and right clicking the mouse pad will bring up a context sensitive menu for features such as “Add”, “Delete”, “Property”, “Enable”, and “Snap shot”.
Page 60
In view mode format click on the icon located on the upper left corner of the screen and a case sensitive menu will appear as illustrated below. Features such as “Enable”, “Snap shot”, “List”, “1 Camera”, “4 Cameras”, “9 Cameras”, “16 Cameras”, “Previous Page” and “Next Page” will be available.
Uninstall IPView Application Click on windows Start Menu / Settings / Control Pane l. A prompt screen will be displayed like the one below and double click on the Add/Remove Programs icon.
Page 62
From the Add/Remove Programs Properties Menu, select “IPView” as illustrated below. Then click on the “Remove” button. A new prompt screen will be displayed like the one below confirming the removal. Click on the “OK” icon to continue the process or click on the “Cancel”...
Page 63
The InstallShield Wizard prompt will appear and click on “Finish” to complete the uninstallation procedure.
Q: What is the maximum number of users that can be allowed to access DCS- 1000 simultaneously? A: Maximum number of users that can log onto DCS-1000 at the same time is 64. Please keep in mind the overall performance of the transmission speed will slow down when many users are logged on.
Page 65
A: No, DCS-1000 is an Internet Camera used only on Ethernet and Fast Ethernet network. Q: Can DCS-1000 be connected on the network if it consists of only private IP addresses? A: DCS-1000 can be connected to LAN with private IP addresses.
DCS-1000 from the network. Start a DOS window. Type ping x.x.x.x, where x.x.x.x is the IP address of the DCS-1000. The succeeding replies as illustrated below will provide useful explanation to the cause of the problem with DCS-1000 IP address.
IP address from this workstation. To verify make sure the first 3 sections of the IP address of the DCS-1000 corresponds to the first 3 sections of the workstation. Therefore the IP address of the DCS-1000 must be set from a workstation on the same subnet.
Page 68
C-type lens without fitting the adaptor first. Q: Noisy images occur how can I solve the problem? A1: The video images might be noisy if the DCS-1000 is used is a very low light environment. To solve this issue you need more lighting.
Page 69
Applying only 16 or 256 colors on your computer will produce dithering artifacts in the image. A2: The configuration on the DCS-1000 image display is incorrect. Through the Web Configuration Image section you need to adjust the image related parameter for improve images such as brightness, contrast, hue and light frequency.
I/O Connector I/O Connector Definition for DCS-1000 An 8-pole connector is provided for auxiliary IO connections to the DCS-1000. The IO connector provides the physical interface for 2 digital output and 2 digital input that is used for connecting a diversity of external alarm devices to the DCS-1000 such as IR-Sensor and alarm relay.
Page 71
I/O Schematic Diagram Warning When connecting a device to the Input connector, the device must be a passive component without voltage and electrical current. When connecting other devices through the Output connector, please make sure the maximum current of DC 5V, 100mA is strictly observed.
Upgrade Firmware User’s can update firmware from the IPView application. Select “Camera” > “Properties” and the Camera Property dialog box will appear. Select the Tools tab and enter the full path of the firmware binary file name in the Update Firmware field or you can click on the “Browse” icon to select the file. Once the firmware file is entered click on the “Update”...
Xplug Control Installation Installation To Web Server Important Information It is highly recommended to install the Xplug Control application to the Web Server for IE 5.0. It must be installed to a Public Domain with Fixed IP address. 1. Installation: Copy the “xplug.ocx”...
Page 76
Installation To Local PC Insert the CD-ROM into the CD-ROM drive to initiated the auto-run program once completed a menu screen will appear as follows: To install Xplug Control click on the "Xplug Control" button to activate the installation procedure for the plug-in program. Once executed a prompt will appear requesting the input of the desired language selection.
Page 77
The License Agreement prompt will appear as below. Read the details carefully and click on the “Yes” icon to continue with the installation procedure. Click on the “Finish” button to complete Setup of the Xplug Control Utility program for DCS-1000.
NOT over turn the lens in either of the directions as it will be out of focus. Unless you want to substitute the lens DO NOT unscrew more than 1.0mm apart from the Fixed Lens Assembly. Keep in mind while adjusting DCS-1000's focus you can review the image quality from the Web browser. Fixed Lens Assembly...
Replacing the Lens Since the DCS-1000 is designed with a CS- mount, the lens equipped with the DCS-1000 can be replaced with any standard C or CS lens commonly used within the surveillance industry. Follow the instructions below to replace the supplied lens with any C or CS type lens.
Pin 7 Output Port (2+) Pin 8 Output Port (2-) Note: The output voltage is DC 5V and maximum current is 100mA. LED Indicator: Power LED (Blue) LAN Activity LED (Orange) Note: LED three mode setting can be changed by software. (Normal / Off / Dummy) Power Supply: DC 5V/2.4A, switching type Power Communication: 4.5 Watt (900mA x 5V)
Technical Support D-Link provides free technical support for customers within the United States during the warranty period. U.S. customers can contact D-Link Technical Support through our web site, e-mail or by phone. D-Link Technical Support over Telephone: (949) 790-5290 6 a.m. to 6 p.m. Monday thru Friday D-Link Technical Support over the Internet: www.dlink.com...