hit counter script

Special Considerations For Cisco Ucs Virtual Interface Cards; Special Considerations For Cisco Ucs Fusion Iodrive2 Storage Accelerator Cards - Cisco UCS C220 M3 Installation And Service Manual

Hide thumbs Also See for UCS C220 M3:
Table of Contents

Advertisement

Chapter 3
Maintaining the Server
g.
h.

Special Considerations for Cisco UCS Virtual Interface Cards

Table 3-8
Table 3-8
Cisco UCS C220 Requirements for Virtual Interface Cards
Number of
VICs
Virtual Interface
Supported
Card (VIC)
in Server
Cisco UCS VIC P81E
N2XX-ACPCI01
Cisco UCS VIC 1225
UCSC-PCIE-CSC-02
Cisco UCS VIC1225T
UCSC-PCIE-C10T-02
Cisco UCS VIC 1285
UCSC-PCIE-C40Q-02
1. See
PCIe Slots, page
3-35.
2. The Cisco UCS VIC1225T is not supported for UCS integration at this time.

Special Considerations for Cisco UCS Fusion ioDrive2 Storage Accelerator Cards

Table 3-9
Table 3-9
Cisco UCS C220 Requirements for Fusion ioDrive2 Cards
Card
Cisco UCS 3.0 TB MLC Fusion ioDrive2
UCSC-F-FIO-3000M
Cisco UCS 1205 GB MLC Fusion ioDrive2
UCSC-F-FIO-1205M
Cisco UCS 785 GB MLC Fusion ioDrive2
UCSC-F-FIO-785M
Cisco UCS 365 GB MLC Fusion ioDrive2
UCSC-F-FIO-365M
1. See
PCIe Slots, page
3-35.
2. Slot 2 is not available in single-CPU configurations.
3. A rear-panel tab adapter is required to fit the half-height cards in full-height slot 1.
OL-25760-01
Replace the server in the rack, replace cables, and then power on the server by pressing the Power
button.
If the card that you replaced was a RAID controller, continue with
After Replacing a RAID Controller, page
describes the requirements for the supported Cisco UCS virtual interface cards (VICs).
Slots That
Support
1
VICs
1
PCIE 1
1
PCIE 1
1
PCIE 1
1
PCIE 1
describes the requirements for the supported Cisco UCS Fusion ioDrive2 cards.
Max. Number of
Cards Supported
C-23.
Primary Slot For
UCS Integration
Minimum
or Cisco Card
CIMC
NIC Mode
Firmware
PCIE 1
1.4(4)
PCIE 1
1.4(6)
2
PCIE 1
1.5(1)
PCIE 1
1.5(4)
Slots That
Support Cards
1
PCIE 1
2
PCIE 1
2
PCIE 2
2
PCIE 1
PCIE 2
2
PCIE 1
PCIE 2
Cisco UCS C220 Server Installation and Service Guide
Installing or Replacing Server Components
Restoring RAID Configuration
Minimum VIC
Minimum Nexus
Firmware For
OS on an Upstream
Use With UCS
Nexus Fabric
Integration
Interconnect
2.0(2)
5.0
2.1(0)
5.0
2.1(1)
5.0
2.2(1b)
5.0
Minimum CIMC
Card Height
1
Firmware
(rear-panel tab)
1.5(2)
Full height
1.5(2)
Half height
1.5(2)
Half height
1.5(2)
Half height
3
3-37

Advertisement

Table of Contents
loading

Table of Contents

Save PDF