Technical Data
Dimensions and Weight
Dimensions
W
H
D (mm)
Weight
Module-Specific Data
Baud rate
Bus protocol
FREEZE compatibility
Number of inputs
Cable length
Unshielded
Shielded
Manufacturer ID
Voltages, Currents, Potentials
Rated supply voltage for
electronics (4L+, 5L+)
Reverse polarity
protection
Power failure with-
stand time
Rated load voltage
(1L+, 2L+ and 3L+)
Maximum number of in-
puts driven simultaneously
Galvanic isolation
Between channels
Between channels and
PROFIBUS-DP
Insulation tested with
Power input
From supply voltage
L4+/L5+
From load voltage L1+
and L2+/L3+ (without
load)
Power loss of module
ET 200L, ET 200L-SC and ET 200L-SC IM-SC Distributed I/O Device
EWA 4NEB 780 6009-02c
The following table shows the technical data of the L 16 DI DC 24 V elec-
tronics block.
145
60
60.5
Approx. 130 g
9.6; 19.2; 93 .75; 187.5;
500 and 1 500 kBaud
PROFIBUS-DP
Yes
16
Max. 600 m
Max. 1000 m
0014
H
24 V DC
Yes
At least 20 ms
24 V DC
16
No
Yes
500 V DC
Max. 70 mA
Max. 50 mA per load
group
Typically 2.2 W
ET 200L Electronics Blocks – Technical Data
Status, Interrupts, Diagnostics
Status display
Interrupts
Diagnostic function
Bus monitoring
PROFIBUS-DP
Monitoring of electro-
nics power supply
Sensor Selection Data
Input voltage
Rated value
At signal "1"
At signal "0"
Input current
At signal "1"
Input delay
With "0" after "1"
With "1" after "0"
Input characteristic
Connection of 2-wire
BEROs
Permissible closed-cir-
cuit current
Green LED per channel
None
Yes
Red "BF" LED
Green "ON" LED
24 V DC
13 to 30 V
-30 to 5 V
Typically 5 mA at 24 V
2.0 to 4.5 ms
2.0 to 4.5 ms
To IEC 1131-2 Type 1
Possible
Max. 1.5 mA