Supported RAID Controllers and Required Cables
Supported RAID Controllers and Required Cables
This server supports the RAID controller options, cables, and RAID backup units shown in
Do not use the embedded MegaRAID controller and a hardware RAID controller card at the same time.
Caution
This is not supported and could result in data loss.
This server supports up to two internal PCIe-style RAID controllers, plus one external PCIe-style RAID
Note
controller. Do not mix internal controller types in the server. You can mix internal controllers with an
external controller.
Note
The embedded RAID option is available only with the SFF 16-drive backplane. It does not operate
through an expander.
The cables in this section apply to both single- and dual-CPU configurations.
Note
Table C-1
Table C-1
Cisco UCS C24 Small Form Factor RAID Options
Controller
Style
1
Embedded RAID
Onboard SFF 16HDD:
2
on motherboard
LSI MegaRAID
PCIe
SAS 9220-8i
LSI MegaRAID
PCIe
SAS 9240-8i
LSI MegaRAID
PCIe
SAS 9265CV-8i
1. The embedded RAID controller must be enabled in the BIOS.
2. Embedded RAID SAS drive control requires an optional SCU ROM upgrade chip to be installed on the motherboard.
3. Support for eight SAS drives requires an optional SCU upgrade ROM module on the motherboard.
4. Integrated RAID 5 support requires an optional software key.
5. The 9220-8i controller can create a RAID array with maximum 16 drives, even if it detects more than 16 drives.
6. In the 16HDD version, two controller cards can be installed to control a total of 16 drives.
7. The 9240-8i controller can create a RAID array with maximum 16 drives, even if it detects more than 16 drives.
Cisco UCS C24 Server Installation and Service Guide
C-2
lists the RAID options for the small form factor (SFF) versions of the server.
SuperCap
Power
Maximum Drives
Module?
No
4 SATA (default) or
3
8 SAS
internal
SFF 24HDD:
No
5
16 internal
SFF 16HDD:
6
8 internal
SFF 24HDD:
No
7
16 internal
SFF 16HDD:
8 internal
SFF 24HDD:
Yes
24 internal
SFF 16HDD:
8 internal
Appendix C
RAID
Levels
Required Cables
Supported
(Each PID is a cable-pair kit.)
4
0, 1, 5
, 10
SFF 16HDD: UCSC-CABLE-A7
0, 1, 10
SFF 24HDD: UCSC-CABLE-A6
SFF 16HDD, 1st-controller: UCSC-CABLE-A7
SFF 16HDD, 2nd-controller: UCSC-CABLE-A8
0, 1, 5, 10,
SFF 24HDD: UCSC-CABLE-A6
50
SFF 16HDD, 1st-controller: UCSC-CABLE-A7
SFF 16HDD, 2nd-controller: UCSC-CABLE-A8
0, 1, 5, 6, 10,
SFF 24HDD: UCSC-CABLE-A6
50, 60
SFF 16HDD, 1st-controller: UCSC-CABLE-A7
SFF 16HDD, 2nd-controller: UCSC-CABLE-A8
RAID Controller Considerations
Table
C-1.
OL-26647-01