MAX60[ACK],
DFT[ACK].
This response indicates that the device's Codabar Coding Enable (CBRENA) is
set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don't Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Trigger Commands
You can activate and deactivate the scanner with serial trigger commands.
First, the scanner must be put in Manual Trigger Mode by scanning a Manual
Trigger Mode bar code
triggering
(page
is activated and deactivated by sending the following commands:
Activate:
SYN T CR
Deactivate: SYN U CR
The scanner scans until a bar code has been read, until the deactivate com-
mand is sent, or until the serial time-out has been reached (see "Read Time-
Out" on page 4-7 for a description, and the serial command on
Resetting the Standard Product Defaults
If you aren't sure what programming options are in your scanner, or you've
changed some options and want the factory default settings restored, scan the
Standard Product Default Settings bar code below.
Note: If using a cordless system, scanning this bar code also causes both the
scanner and the base to perform a reset and become unlinked. The
scanner must be placed in its base to re-establish the link before any
setup codes are entered. See
page 3-1 for additional information.
The charts on the following pages list the factory default settings for each of the
commands (indicated by an asterisk (*) on the programming pages).
11 - 4
(page
4-6), or by sending a serial menu command for
11-18). Once the scanner is in serial trigger mode, the trigger
Standard Product Default Settings:
Current Application Group
Cordless System Operation
page
11-18).
beginning on