Module....19 locate . . 68 Installation and setup . . 19 list features . 71 The IBM BladeCenter Start Now Advisor method . 21 mountpolicy . . 71 The Advanced Management Module method . . 21 mountstate .
Page 6
Replacing a single controller in a dual controller People's Republic of China Class A electronic configuration using the CLI . 164 emission statement . 198 IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 7
Taiwan Class A compliance statement . . 199 Index ....201 Contents...
Page 8
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Tables Interfaces and functions . Tape devices supported by the IBM Important notes BladeCenter S SAS RAID Controller Module . 95 Features . Light path diagnostics LED details . . 98 Battery Backup Unit part number . . 13 Alert types generated by the RAID Controller 106 RAID levels and characteristics .
Page 10
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
IBM Storage Configuration Manager (SCM) The IBM Storage Configuration Manager is a web-based system management application that you can use to update firmware on the IBM BladeCenter S SAS RAID Controller Module, DSM, and DDM, as well as manage and configure ®...
IBM BladeCenter S SAS RAID Controller Module. This guide is updated periodically, so check this location for the latest copy: https://www.ibm.com/ systems/support/supportsite.wss/docdisplay?lndocid=MIGR-5073016 &brandind=5000020. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
The IBM BladeCenter S SAS RAID Controller Module functions only within the IBM BladeCenter S chassis. The following are also required: v One or two IBM BladeCenter S SAS RAID Controller Modules. If you install two SAS RAID Modules, you must install them in I/O module bay 3 and I/O module bay 4.
1 and bay 2 of the media tray. You can obtain up-to-date information about the SAS RAID Modules and other IBM products at http://www.ibm.com/systems/support/ IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
The major components topic contains an illustration that shows the location of the SAS RAID Modules labels. Note: This information is required when you register the SAS RAID Modules with IBM. Preinstallation safety information This topic contains important safety information. Read before installing this product.
Page 16
Antes de instalar este produto, leia as Informações sobre Segurança. Antes de instalar este producto, lea la información de seguridad. Läs säkerhetsinformationen innan du installerar den här produkten. Statement 1 IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 17
Statement 2 CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer.
Take additional care when handling devices during cold weather. Heating reduces indoor humidity and increases static electricity. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Hardware features and specifications This section provides a summary of the features and specifications for the IBM BladeCenter S SAS RAID Controller Module. The SAS RAID Modules support the following features: v 6 internal 1X SAS 3.0 Gb host connectivity to 6 blade slots v 2 internal 4X SAS 3.0Gb to 2 disk storage module (DSM) systems...
The following illustrations show the front and rear views of an IBM BladeCenter S chassis. Your hardware might have labels not shown in the following illustrations. Figure 1. Front view of an IBM BladeCenter S chassis IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
The connectivity module option package contains the following items: v One IBM BladeCenter S SAS RAID Controller Module v One Battery Backup Unit (45W5002) is bundled with each IBM BladeCenter S SAS RAID Controller Module. v The RAID Controller Getting Started Guide v The Support CD, which includes: –...
IBM Planning and Installation Guide for your BladeCenter unit to help you prepare for system installation and configuration. For more information, see http://www.ibm.com/systems/support/. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Note: Like all batteries, Battery Backup Units degrade over time. You should install Battery Backup Units within 90 days of the date of purchase so that they can begin recharging, and do not take them out of the IBM BladeCenter S chassis for extended periods of time.
Lit (green). The Battery Backup Units is being charged. Off. Fault Lit (amber). The Battery Backup Units has a failure. If the Fault LED is lit, replace the Battery Backup Units. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
This topic shows the mechanics of performing a physical installation of the Battery Backup Units. The Replacing a battery section of this document details the steps to take to prepare the IBM BladeCenter S SAS RAID Controller Module for a battery replacement.
Page 26
Procedure 1. Open the release handle (rotate the handle down) 2. Slide the battery backup unit out of the media tray. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
IP assigned to it. If you are using the default IP address your management system (the computer you are using to manage your IBM BladeCenter S components) must be physically connected through an Ethernet cable to the Advanced Management Module .
Page 28
10. At the Password prompt, type the initial default password, PASSW0RD (the sixth character is a zero). 11. Click OK. The Command Line Interface Shell screen opens. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Chapter 4. Installing the IBM BladeCenter S SAS RAID Controller Module This topic details the IBM BladeCenter S SAS RAID Controller Module installation and setup procedures. Before you begin Before you begin, do the following: 1. Install a SAS Expansion Card (CFFv) for IBM BladeCenter (Part Number - 39Y9190) into each Blade server that you want to communicate with the RAID Controller.
Page 30
A non-guided manual configuration using a direct connection to the Advanced Management Module. Log into the Advanced Management Module and perform the rest of the setup tasks. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
The Advanced Management Module method About this task After you install the IBM BladeCenter S SAS RAID Controller Module, you can log into the Advanced Management Module and set the parameters of the modules so that you can begin configuring your integrated storage.
Page 32
What to do next If you experience any problems with setting these parameters, review the advanced verification procedures in the Troubleshooting section of this document. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
5. When prompted to choose an install type, select SCM Full Install for all devices. 6. After you install the IBM Storage Configuration Manager, you are prompted to restart your workstation. TheIBM Storage Configuration Manager service starts automatically upon restart.
Module in bay 4 successfully powers on. The On message will be displayed in the Pwr column, and the message POST results available: Module completed POST successfully will display in POST Status column. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Slide the RAID Controller into the module bay until it stops. c. Close the release handle by rotating the handle up. d. Connect all cables to the module. Chapter 4. Installing the IBM BladeCenter S SAS RAID Controller Module...
Page 36
LUNs Mapped : ___________________________________________________________ Permission Volume |_________|_____________________|___________________________| ACCESS_READWRITE| Raid10_Pool:r10_vol_1| ACCESS_READWRITE| Raid10_Pool:r10_vol_10| ACCESS_READWRITE| Raid10_Pool:r10_vol_4| ACCESS_READWRITE| Raid10_Pool:r10_vol_3| ACCESS_READWRITE| Raid10_Pool:r10_vol_2| ACCESS_READWRITE| Raid10_Pool:r10_vol_9| ACCESS_READWRITE| Raid10_Pool:r10_vol_8| ACCESS_READWRITE| Raid10_Pool:r10_vol_7| ACCESS_READWRITE| Raid10_Pool:r10_vol_6| IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 37
<CLI> hostlun -map -volume Raid10_Pool:r10_vol_8 -permission rw -wwn 500062b00007e569 -name CliHost1 -lun 6 Working ... Host LUN 6 for host 500062b00007e569 and host name CliHost1 mapped to volume ’r10_vol_8’ in ’Raid10_Pool’ Chapter 4. Installing the IBM BladeCenter S SAS RAID Controller Module...
Page 38
HostWWN 500062b00007e569, HostName CliHost1 : LUNs Mapped : ___________________________________________________________ Permission Volume |_________|_____________________|___________________________| ACCESS_READWRITE| Raid10_Pool:r10_vol_1| ACCESS_READWRITE| Raid10_Pool:r10_vol_2| ACCESS_READWRITE| Raid10_Pool:r10_vol_3| ACCESS_READWRITE| Raid10_Pool:r10_vol_4| ACCESS_READWRITE| Raid10_Pool:r10_vol_10| ACCESS_READWRITE| Raid10_Pool:r10_vol_9| ACCESS_READWRITE| Raid10_Pool:r10_vol_8| IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 39
ACCESS_READWRITE| Raid10_Pool:r10_vol_7| ACCESS_READWRITE| Raid10_Pool:r10_vol_6| ACCESS_READWRITE| Raid10_Pool:r10_vol_5| |_________|_____________________|___________________________| If the upgrade did not complete successfully, collect the logs and contact IBM. Chapter 4. Installing the IBM BladeCenter S SAS RAID Controller Module...
Page 40
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Note: A 9401 alert event is logged in the system if one of the following occurs: v The IBM BladeCenter S SAS RAID Controller Module is not turned off and the chassis is disconnected from the power source for more than 72 hours...
Page 42
Note: After you disconnect the BladeCenter S chassis from power, wait at least 30 seconds before you connect the BladeCenter S chassis to power again. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Controller Module and the Advanced Management Module. After completing the installation procedures, check the current firmware level shipped on the IBM BladeCenter S SAS RAID Controller Module and visit the IBM BladeCenter support Web site to ensure that it is operating with the latest version of firmware.
IBM Support website at http://www.ibm.com/support/. Follow the instructions attached to the code package to install and configure firmware updates. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
RAID level to it which will provide a redundancy level. You can create a storage pool using IBM Storage Configuration Manager or by using the create pool command in the RAID Controller command line interface (see “create pool”...
RAID 10 uses a process called striping across mirrors. This process requires a set of even numbered disks, with four disks being the minimum number required. The IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
(4,6,8,10,12 drives). Understanding the predefined storage configuration When you install your IBM BladeCenter S SAS RAID Controller Module, a predefined configuration is available to get you started. This topic details the specifics of that predefined configuration. Canned configuration The predefined configuration packaged with IBM BladeCenter S SAS RAID Controller Module is referred to as a canned config within the interface itself.
| Slot 0 | 3832GB| 366GB|Viable| ONV | | 1 | 1|raid1| | Slot 1 | 279GB| 247GB|Viable| ONV | |____ |__|_____|________|_________|________|________|______|_____|________| Using IBM Storage Configuration Manager (SCM) IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 49
a. From the SCM navigation panel, select Health > Physical View, then select the Controllers tab. Select each controller and ensure both controllers have a status of Normal (Online). b. From the SCM navigation panel, select Configuration > Storage, then select the Storage Pools tab.
SAS Expansion Card, you can temporarily disable the Onboard SAS Controller by pressing F1 during the boot; this removes the Onboard SAS Controller from IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 51
the Adapter List screen and the remaining entry will be the SAS Expansion Card. HS20 and LS20 blade types will have a single SAS entry by default as the internal hard drive is connected using SCSI. Figure 4. Adapter List screen showing Onboard SAS Controller and SAS Expansion Card 2.
Page 52
Devices and I/O Ports screen displays. Figure 9. Devices and I/O Ports screen 2. Press Esc to exit the Devices and I/O Ports screen. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 53
3. When the <<<Press Ctrl-C to start LSI Logic Configuration Utility>>> prompt displays during system boot, press Ctrl+C to enter the LSI Logic Configuration Utility. The Adapter List screen displays, similar to Figure 10. Figure 10. Adapter List screen showing SAS Expansion Card 4.
Page 54
LUN1 or higher. If you start the drive mapping at LUN0, a boot delay will occur. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 55
For blades that have the SAS Connectivity Card and are configured to be booted from an external SAS drive, the internal hard drive must be removed. Except for the requirements to remove the internal disk and to map a boot volume to the blade, the configuration for internal hard drive boot and external SAS boot is identical.
Page 56
URL field. If you have the Advanced Management Module connected to your network, log in using the network IP assigned to it. If IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 57
IP address your management system (the computer you are using to manage your IBM BladeCenter S components) must be physically connected through an Ethernet cable to the Advanced Management Module . Note: The default IP address for the Advanced Management Module is 192.168.70.125.
Page 58
5. For IGMP settings, select Disable from the list of options. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
BBU Firmware Revision : 58.0 BBU Expiration Date : Sat Jul 23 12:00:00 2016 Charging state information BBU Charging : False BBU Capacity (Hours) : 72+ IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
| Mount State |Ctl0|Ctl1| RPM |FW level| |_____________|____|____|_______|________| Online| 7200| BC1D| |_____________|____|____|_______|________| Drive SAS Address : 5000c5000d218b73 Vendor / Manufacturer ID : IBM-ESXS IBM Option Number : 42D0546 IBM FRU Number : 42D0548 IBM Part Number : 42C0279 Interface Type : SAS Disk Speed : 7200...
If the missing drive comes back to make the pool viable, the state automatically changes to MV. When you acknowledge the alert, the state of the pool becomes UN. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Information about a drive in the primary section is as follows: __________________________________________________________________________________________ | Slot | SerialNo | Cap | Grp | Usage | State | Mount State | Ctl0 | Ctl1 | |________|______________ ___|_______|________|_______|_______|_____________|______|______| 1:5| DQR9P6C00D3F| 33GB| DG2| GRP| Mounted| |________|__ _______________|_______|________|_______|_______|_____________|______|______| Information about a drive in the secondary section is as follows: _________________________________________________________________________________________...
Page 64
784875485454| READWRITE| |_____________________|___________|__________________| Pool information: ___________________________________________________________________________________________ | ID | Name |RaidType|OwnerCtlr|TotalCap|AvailCap| Status | State | Degraded |____|___________|________|_________|________|________|____________|__________|____________| pool1| IO 3| 33GB| 28GB| Viable| |____|___________|________|_________|________|________|____________|__________|____________| IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
detail volume verbose The detail volume verbose command creates output detailing information about all of the Logical Unit Numbers (LUNs). A LUN is a number assigned to a logical unit. Command arguments: <CLI> detail volume verbose Example: <CLI> detail volume verbose ______________________________________________________________________ Name |RaidType| HostWWN...
|Drive# | E:T | SerialNo | Cap | Pool | Usage | State | Mount State | Ctl1 | Ctl2 | RPM | |_______|______|______________|_______|______|_______|_______|_____________|______|______|______| IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
[-savehistory] : Saves alert history into a file. -code : alert code of the alert you want to take action on. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
: id of the alert message to be taken action on . -ctlr : slotID of the controller where you want the action to be taken place on an alert message. [-create] : This option can be used to create a generic alert with the alert code specified by ’-code’...
If you specify the –get option, the system default setting is displayed. If you specify the –ctlrsetting option, the write cache settings for the controller are set. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
chpasswd Use this command to change the password for the selected user on an SAS RAID Module. If the firmware level of your RAID controllers is older than 1.2.x.xxx, you need to change the password on both SAS RAID Modules at the same time. If the firmware level of your RAID controllers is 1.2.x.xxx or newer, then changing the password on one SAS RAID Module automatically changes the password on the other SAS RAID Module.
configure alert The configure alert command selects the alert messages to send by email. Previously configured messages display as configured and can be cleared. Use the -get option to display the list of alerts and to build a local list of system alerts before using the –set option to configure the alerts.
An error appears if you issue the -set option while the list is empty or if the timeout value is invalid. Command arguments: <CLI> configure timeout -[get | set <HR:MIN:SEC> | help] -help option IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
<CLI> configure timeout -[get | set <HR:MIN:SEC> | help] Usage : configure timeout -[get | set <HR:MIN:SEC> | help] [-get] : Displays the CLI session timeout settings [-set] : Sets the CLI session timeout period. : Number of hours. The number must be less than two digits. : Number of minites.
: Deletes specific email id EMAIL : EmailId of the person who wants to get the alerts. SERVER : IP address of the SMTP server . IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
PORT : Port number on which SMTP server listens . SENDER : Sender’s full IP address. SMTP domain name is extracted from it so it must be valid for email to work.The format of this input should be in user@domain format.
If the selected object is a drive, the LED on that drive is litup. If the selected object is a pool or a volume, LEDs on all the drives making up that IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 79
object light up. The object can be specified using either the name or sequence number in the list returned by ’-getobject’ command. [-getobject] : This command with ’-getobject’ option is used to get a list of all the objects of that type. [-off] : Turns off the LEDs on all components Examples:...
Page 80
<CLI> locate –setobject –drive all <CLI> locate –getobject –volume Vol# VolName# GrpName# Capacity# HostLUN# Host-WWN testVol0 Grp1 1024 23abcd testVol1 Grp2 3590 abdef3 <CLI> locate –setobject –number 2 IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
list features Use this command to display currently enabled feature fields. Command arguments: <CLI> list features Example: <CLI> list features Current Machine Local Time: 08/26/2008 03:25:34 PM ____________________________________________________ | S.No | Features Availability |______|_________________________|___________________| Base Features | Enabled | Bound Mode | Enabled | Volume Copy | Disabled |...
Page 82
A dual controller reboot is required to bring the pool back online. <CLI> mountstate -setobject -dismount -pool my_pool IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Note: Once a pool is dismounted, the pool can not be mounted using the mountstate -setobject command. A dual controller reboot is required to bring the pool back online. <CLI> mountstate -setobject -dismount -bbu 1 <CLI> mountstate -setobject -mount -bbu 1 <CLI>...
Command arguments: <CLI> service mode –getreason Reason details : string Recovery Hints : string IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Where: v -getreason lists any appropriate recovery options. Example: <CLI> service mode –getreason Current Machine Local Time: 08/26/2008 03:35:15 PM The reason for service mode is “DRV_MISMATCH_RB”. Reason details : “Rebinder does not see the same drives as survivor.” Recovery Hints : “Reboot or Replace the controller” shellscript The shellscript command runs a shell script in the RAID controller.
’-state online’ option to the active controller. If the controller to which this CLI session is connected to is being requested to be powered off,the user will lose the CLI session. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
swversion The swversion command retrieves and displays the software version. Command arguments: <CLI> swversion Example: <CLI> swversion Current Machine Local Time: 11/27/2009 11:27:09 PM Software version : H-2.0.2.6 UBoot version : H-1.1.4.5 OS version : H-2.4.20.11 SES version : 0105 BMC version : S0BT07c 011A 06/30/2009...
[POOL_NAME] - Specifies the name of the drive pool. v [ENCLOSURE]:[TRAY] - Specifies the drive bay number by enclosure number and tray number. Example: <CLI> add mirror -pool Grp1 -drives 1:1 1:3 IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
assimilate drive Use this command with foreign drives, which are drives that were written on another system using the controller software or a system using another vendor’s software. By running this command with the -set option, you can record the information pertinent to this controller in the drive region reserved for metadata.
PORT : Port value can be either ’0’ or ’1’. POOL_NAME : Pass a unique name for this Drive Pool Pool name is maximum of 12 characters and contains only alphanumeric and underscores. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Where: v [ENCLOSURE]:[TRAY] - Specifies the drive bay number by enclosure number and tray number. v [0|1|10|5] - Allows selection of raid type. v [0|1] - Allows selection of port. v [POOL_NAME] - Defines the name of the pool. A drive pool is a defined set of drives. Each volume that is exposed to host systems is completely contained within a drive pool.
An error message is displayed if the target pool is not found. Example: <CLI> delete pool –name Group0 No such drive pool Please re-execute the command with valid pool name available IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
delete volume This command deletes a master volume. Command arguments: <CLI> delete volume –name poolname:volumename Where: v poolname:volumename - Specifies pool name and volume name. Volume name can be up to 12 characters long and contain alphanumeric and underscores; it must be unique across the pool on which it is created.
<CLI> host –get HostWWN 784875485454 : LUNs Mapped Permission Volume ACCESS_READWRITE pool1:vol1 HostWWN 123456789abcdef0 : No LUNs Mapped HostWWN 123456789abcdef1 : No LUNs Mapped IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
hostlun Use this command to map or unmap a volume to a host using the specified LUN number or to get a list of all host LUNs. Important: When using this command with the -unmap argument to unmap a volume to a host, the command requires you to end all application I/O processes on the LUN that is being unmapped and to shut down any active Blade servers in accordance with the recommended non-concurrent practices.
(tray) number. You can add one or more drives to the pool. Example: <CLI> add capacity –pool Group0 –drivelist 1:3 Capacity added successfully IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
datascrub The datascrub command views or sets the datascrub policy. The -auto flag specifies whether background scrub should be enabled. If a problem is found, the policy to fix it or create bad blocks is defined in the flash configuration file. Command arguments: <CLI>...
synchronize volume The synchronize volume command synchronizes a volume immediately to ensure that redundant information is valid. You can also use this command to perform a parity check on RAID 5 volumes and a mirror consistency check on mirrored volumes. Any errors found during the check are handled according to the defined datascrub policy found in the flash configuration file.
Due to the nature of RAID technology, the default predefined zone used with the IBM BladeCenter S chassis is set so that all the Blade Servers can communicate with all of the disk storage. In the course of troubleshooting, you might want to isolate a Blade Server as a diagnostic tool, but it is recommended that you maintain the default zoning settings for regular operations.
Page 104
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
SAS storage tape device. This chapter describes the installation process for the following supported tape devices: Table 8. Tape devices supported by the IBM BladeCenter S SAS RAID Controller Module Supported tape devices IBM System Storage TS2230 Tape Drive Express Model...
8. If the tape device is not visible after completing these steps, contact IBM support. For additional information about the supported tape devices, go to http://www.ibm.com/support. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Controller into service mode, see the "Shutdown and Recover" topic in the IBM Storage Configuration Manager online help. Understanding LEDs This topic describes what the LED lights on your IBM BladeCenter S SAS RAID Controller Module signify. Power – OK LED Power Indicators are used on each component to indicate the status of the power distribution network within that component.
Manager to provide a notification that the storage system is in a state that requires attention. The system information LED is also used by the Light IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 109
Manager to provide an external indication that the SAS RAID Module storage system has an activity in progress that might prevent access to the SAS RAID Module management facilities through the user interfaces. Valid States: OFF, SOLID, SLOW BLINK OFF – There are no conditions that require attention. SOLID –...
Page 110
FLASHING – The flash rate of the Activity LED indicates SAS RAID Module a rate proportional to the level of SAS interface (host and/or device) activity as determined by the SAS Bridge Device. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 111
Figure 22. SAS RAID Module light path indicators Battery backup unit light path indicators and valid states The SAS RAID Module relies on each battery backup unit to provide power to preserve its respective SAS RAID Module cache memory. Each battery backup unit supports the following light path indicators and valid states.
Page 112
OFF – There have been no faults or conditions detected by the SAS RAID Module with the DSM that can be serviced using the light IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 113
path diagnostics indicators. The DSM is not in a condition that permits a repair/replacement activity. SOLID – There has been a fault / condition detected by the SAS RAID Module with the DSM that can be serviced using light path diagnostics indicators.
Using a secure shell, log into the RAID Controller. v The default username is: USERID v The default password is: PASSW0RD (the sixth position is the numeral zero) IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
This topic details how to read alerts you might see while administering your RAID Controller. The IBM BladeCenter S SAS RAID Controller Module displays alert information that keeps you informed as to the state of your system while providing for advanced diagnosis and guidance to correct errors and device failures.
0xxx – System Status Information Alert Codes v 1xxx – Failure Detected or Predicted Alert Codes v 2xxx – Ready for Service Alert Codes IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
v 4xxx – Warning – Action Required Alert Codes v 5xxx – Warning – Possible Action Required Alert Codes v 9xxx – Critical Status Notification Alert Codes Note: The thousands digit indicates the severity and user action. The hundreds digit indicates the RAID Subsystem component associated with the alert: v 0xx Enclosure v 1xx Controller HW-FW...
See “Replacing a single controller using the CLI” on page 154 or “Replacing a single controller using the SCM” on page 155. This alert can be masked so that it does not trigger the SAS RAID Module system information indicator. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 119
5001 • 9000 5001 Controller warning - power supply voltage out of range Explanation: Power supply voltage is not yet critical, but is out of the normal operating range. Potential causes are power supply failure and controller sensor failure. System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is notified of this alert by e-mail.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is not notified of this alert by e-mail. Alert clears automatically after 120 seconds. Operator response: Acknowledge to clear the alert immediately. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 121
0004 • 4010 0004 Drive enclosure enclosure_ID firmware updated Explanation: Drive enclosure firmware has been successfully updated. The controller updates drive enclosure firmware as part of the controller firmware update process initiated by the user or automatically whenever a non-matching drive enclosure firmware revision is detected during controller system boot. System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is not notified of this alert by e-mail.
Page 122
“Replacing a Disk Storage Module (non-concurrent procedure)” on page 161). This alert can be masked so that it does not trigger the SAS RAID Module system information indicator. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 123
5013 • 9004 5013 Drive enclosure enclosure_ID warning - power supply current out of range Explanation: Drive enclosure power supply current is not yet critical, but is out of the normal operating range. Potential causes are power supply failure and current sensor failure. System action: By default, the SAS RAID Module system information indicator is turned on and the operator is notified of this alert by e-mail.
Page 124
To avoid indeterminate data loss, ensure that the “data in cache” indicator is not illuminated before removing any controller or battery. Do not restart the system with any previously connected drive missing. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
0101 • 0111 Controller informational alert history log events The alerts in this section are generated for logging controller status. These operator never sees them as active alerts. 0101 Disorderly shutdown detected - System restored from battery backup Explanation: The controller backup battery system allows for recovery of cached write data when power fails unexpectedly.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator. Masking the alert does not prevent the controller fault light from illuminating. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
0102 • 1101 Controller warning alerts The alerts in this section are generated as controller state warning messages. 0102 Controller in survivor mode - Redundant controller controller_ID is offline Explanation: In a redundant controller system, if one controller enters service mode and the other survivor controller assumes ownership of all LUNs, the surviving operational controller generates this alert.
Page 128
Operator response: Use manual to determine proper drive configuration for Zero Step Setup. If the alert is still active more than 60 seconds after you ensure that the correct drive configuration exists, perform a Disk Connectivity Diagnosis. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 129
4101 • 5002 This alert can be masked so that it does not trigger the SAS RAID Module system information indicator. 4101 Controller diagnostic information available. Please collect controller logs. Explanation: Uncollected cdump image exists and overwrite protection delay has not expired. System action: By default, the SAS RAID Module system information indicator is turned on and the operator is notified of this alert by e-mail.
If alert 1104 is generated again after the reboot, replace the controller. See “Replacing a single controller using the CLI” on page 154 or “Replacing a single controller using the SCM” on page 155. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 131
1105 • 1107 1105 Controller controller_ID critical failure detected - Unrecoverable HW error Explanation: An unrecoverable hardware error has been detected in the controller. The controller continually monitors the health of the RAID Storage Processor and microprocessor subsystem. When this alert is generated, the controller can no longer continue normal operation.
Page 132
The alert clears automatically when the controller enters redundant operation or reboots as a survivor controller. Operator response: Look for additional alerts to determine the reason why the controllers cannot bind. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
9100 • 9103 9100 Controller controller_ID FW update failed Explanation: The controller firmware update process has failed. System action: By default, the SAS RAID Module system information indicator is turned on and the operator is notified of this alert by e-mail. Alert clears when a firmware update completes successfully. Operator response: Perform the following steps: 1.
Page 134
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is not notified of this alert by e-mail. Alert clears automatically. Operator response: None. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
0206 • 0210 0206 Battery battery_ID connected to memory Explanation: Battery has been connected to memory and will provide some amount of battery backup. System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is not notified of this alert by e-mail.
Page 136
Operator response: Correct the problem. Ensure that a working battery is in place (see “Replacing a Battery Backup Unit” on page 177). This alert can be masked so that it does not trigger the SAS RAID Module system information indicator. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 137
4200 • 5201 4200 Battery missing Explanation: Configuration supports a battery, but no battery is detected by the SES controller. System action: By default, the SAS RAID Module system information indicator is turned on and the operator is notified of this alert by e-mail. Alert clears when a battery is inserted. Operator response: Insert a battery (see “Replacing a Battery Backup Unit”...
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is not notified of this alert by e-mail. Alert clears automatically after 120 seconds. Operator response: Acknowledge to clear the alert immediately. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 139
0308 • 2000 0308 Replacement drive drive_ID detected, and assigned as global spare Explanation: A new replacement drive has been detected and assigned as a spare. System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is not notified of this alert by e-mail.
Page 140
Operator response: Replace the battery (see “Replacing a Battery Backup Unit” on page 177). This alert can be masked so that it does not trigger the SAS RAID Module system information indicator. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
2300 • 0317 2300 Drive drive_ID ready for service Explanation: Drive is ready for removal. Possible causes: v Dismount request from operator v Presence of an unreliable drive (failed or undiscoverable yet detected by SES) v Presence of an unsupported drive System action: Drive fault light turns on, indicating "ready to remove"...
Page 142
Operator response: Replace the failed drive (see “Replacing a failed drive” on page 167). This alert can be masked so that it does not trigger the SAS RAID Module system information indicator. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 143
1301 • 1307 1301 Drive drive_ID failure detected - Previous drive status was unassigned Explanation: Drive failure condition caused controller to fail an unassigned, foreign, or IM drive. System action: Drive mount state is set to DISMOUNTED. By default, the SAS RAID Module system information indicator is turned on and the operator is notified of this alert by e-mail.
Page 144
SAS RAID Module system information indicator is turned on and the operator is notified of this alert by e-mail. Alert clears when the unsupported drive is removed. Operator response: Remove the unsupported drive. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 145
4301 • 4304 4301 Unmasked drive firmware level is unsupported Explanation: A disk drive with an unsupported firmware level is detected by the controller. System action: The controller will not configure the disk drive. Operator response: Remove the disk drive with the unsupported firmware level, or upgrade the disk drive firmware level.
Page 146
Alert clears automatically when at least one drive is discovered. Operator response: Acknowledge to clear the alert immediately. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 147
5305 • 5311 5305 Unreliable drive drive_ID detected. Explanation: Unreliable drive discovered. System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is notified of this alert by e-mail. Alert clears when the drive is removed. Operator response: Acknowledge to clear the alert immediately.
Page 148
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not notified of this alert by e-mail. Alert clears automatically after 120 seconds. Operator response: Acknowledge to clear the alert immediately. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
9304 • 0400 9304 One or more outstanding alert 9302 conditions exist. Acknowledge to proceed with shutdown. Explanation: System shutdown initiated with outstanding 9302 alerts. System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not notified of this alert by e-mail.
Page 150
Operator response: This alert can be masked so that it does not trigger the SAS RAID Module system information indicator. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 151
4010 • 5403 4010 No viable drive groups available in system Explanation: At least one configured drive group member drive is discovered, but no viable drive groups exist in the system. Non-viable drive groups cannot expose LUNs to any host because the controller cannot create a complete data set from the drives that are present.
Page 152
Note: In the R1 release, you must reboot the system with the missing drives in place in order to return the group and its associated volumes to the mounted viable state with mapped LUNs online and accessible. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 153
5720 • 9406 5720 Spare drive carrier tray_ID has been disqualified, drive carrier spare drives converted to global spares Explanation: A group is created such that an existing spare tray is no longer qualified as a spare tray. System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not notified of this alert by e-mail.
Page 154
Operator response: Acknowledge to clear the alert immediately. Note: Acknowledging the alert causes the affected drive group to be removed from the MG list. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
9412 • 3500 9412 Drive group group_ID volume migration in progress and destination group is missing. Volumes not completely migrated to destination have been deleted. Explanation: Volume migrate was suspended or interrupted, and the destination group is not available at system reboot time.
Page 156
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not notified of this alert by e-mail. The volume is deleted. Operator response: Acknowledge to clear the alert immediately. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
9511 • 5600 9511 Volume volume_ID data redundancy error encountered - Bad blocks created in LBA range LBA1 to LBA2 Explanation: Redundancy scan found and corrected incoherency, but created bad blocks. System action: By default, the SAS RAID Module system information indicator is turned on and the operator is notified of this alert by e-mail.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is not notified of this alert by e-mail. Alert clears automatically. Operator response: None. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 159
0703 • 5701 0703 Controller identity updated Explanation: Other controller and backplane WWNs match each other, but the WWN of this controller does not match them. System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is not notified of this alert by e-mail.
Page 160
Operator response: Perform the following steps: 1. Correct the problem. 2. Reboot the controller. 3. If the problem persists, perform a concurrent controller firmware update. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
The collected files are aggregated into a single tar file. The tar file is named using the date, time and the IBM BladeCenter S chassis serial number. An example for a file collected on June 2, 2008 (20080602) at 3:17:42 PM (151742 in 24-hour time) from the RAID Controllers in IBM BladeCenter S chassis 23A6789 is as follows: 20080602.151742.23A6789.tar...
FTDC Utility and enter this parameter. Keep in mind that the First Time Data Capture Utility may disrupt host I/O operation. Do not enter this parameter unless directed to do so by the program. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 163
-ldir This optional parameter supplies the name of a subdirectory where the program stores the tar file. If you do not supply the parameter, the program places the tar file in a subdirectory named ftdc_files. Note: The directory name supplied with this parameter must be valid for the operating system in use (Windows or Linux).
|_____________|________________|____________________|_________|_________| 6. At the <CLI> prompt, enter shutdown –ctlr <CONTROLLER 0 OR 1> –state servicemode –readytoremove and press Enter to prepare the controller for IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
3. Remove any externally attached devices that are connected to any of the four SAS ports on the RAID Controller that is being replaced. 4. Log into the IBM Storage Configuration Manager. 5. From the navigation panel, select BC-S SAS RAID Module > Health >...
Page 166
Click Off next to Location. The blue chassis identification LED will turn off. Results If the problem is not resolved, collect the logs and contact IBM. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
7. Verify that the SAS RAID Modules are operating in a dual configuration mode. a. Log into IBM Storage Configuration Manager. b. Select BCS SAS RAID Module > Health > All Resources. c. Verify that the status is Normal (Online).
| Ports | LUNs |_____________|________________|____________________|_________|_________| Ctlr0| PRIMARY| Ctlr1| SECONDARY| |_____________|________________|____________________|_________|_________| <CLI> shutdown -system -state servicemode Current Machine Local Time: 03/04/2013 04:37:16 PM Shutdown Command Successful IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 169
4. Remove the 6-DSM from the chassis. a. Open the release handles on the DSM (rotate the top handle up and the bottom handle down) to disengage the DSM from the IBM BladeCenter S chassis. b. Slide the DSM out of the IBM BladeCenter S chassis.
Go to Shutdown and Recover page to reboot both controllers. This message indicates that the SAS Switch firmware update completed successfully. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
DSM. If at least one IBM BladeCenter SAS Connectivity Module is installed in the IBM BladeCenter S chassis, the location of each drive is determined by the IBM BladeCenter SAS Connectivity Module zoning configuration that you have selected for the IBM BladeCenter S system.
Make a note of the Current IP Configuration for SAS Switch Subsystem. The values to note are: v IP Address v Subnet Mask IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 173
8. Insert the new Media Tray into the chassis. a. Slide the media tray into the IBM BladeCenter S chassis until it stops. b. Close the release handles (rotate the top handle down and the bottom handle up).
|_____________|________________|____________________|_________|_________| 5. At the <CLI> prompt, enter shutdown –ctlr <CONTROLLER 0 OR 1> –state servicemode –readytoremove and press Enter to prepare the controller for IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 175
Click Monitors > LEDs > Media Tray and Rear Panel LEDs. c. Click Off next to Location. The blue chassis identification LED will turn off. Results If the problem is not resolved, collect the logs and contact IBM. Chapter 11. Troubleshooting and support...
19. Ensure that no additional warnings or critical alerts are generated for the replacement controller. 20. Connect any externally attached devices that were previously connected to any of the four SAS ports on the RAID Controller. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
8. To verify that the alerts related to the failed drive are no longer in the Active Alert List, select BCS SAS RAID Module > Health > Active Alerts. 9. If the problem is not resolved, collect the logs and contact IBM. Chapter 11. Troubleshooting and support...
|RaidType|OwnerCtlr|TotalCap|AvailCap| Status | State | Degraded |____|_____________|________|_________|________|________|_________|__________|____________| | 1 | RAID10_Pool | 10 | Slot 1 | 2095GB | 1975GB | Viable | ONV | No IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 179
|____|_____________|________|_________|________|________|_________|__________|____________| State: OFN/SN=Offline Non-viable/Service Non-viable ONF/OFF/SF=Online Failed/Offline Failed/ Service Failed ONV/OFV/SV= Online Viable/Offline Viable/Service Viable ONN=Online Non-viable/Pending Non-Viable; one or more drives are missing in this pool. The pool state changes to ONV if missing drive(s) comes back to the pool. The pool state changes to OFN if the user acknowledges the alert.
Page 180
|-----------------------------------------------------------------------------------------| | Msg: Drive 01:02 ready for removal |=========================================================================================| | 2300 | 39 | 20090915141523 | 1 | Info |5005076b0741417f| 0 | Unmasked | IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 181
State: OK=healthy M=missing P=PFA predicted failure U=unreliable (M/P/U can be combined) INI=initialized UNS=unsupported (non-IBM) drive PM=path missing IMD=incompatible metadata with this software version; either assimilate drive or update controller firmware. UNF=firmware version unsupported for drive 11. Enter list pool and press Enter to list the pool summary for each storage pool.
Page 182
DSM, alert 5014 will generate to indicate that the DSM firmware versions are not equivalent. To resolve this condition and clear the alert, perform a non-concurrent system reboot or non-concurrent firmware update. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
UNF=firmware version unsupported for drive What to do next If the problem is not resolved, collect the logs and contact IBM. Removing and reinserting an active controller You can resolve some software problems associated with an IBM BladeCenter S SAS RAID Controller Module by removing and reinserting the same RAID Controller without significant interruption to the server.
Page 184
4. In the Inactive session timeout value field, select the timeout value for this Web session and click Continue. The Advanced Management Module window opens. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Slide the RAID Controller into the module bay until it stops. c. Close the release handle by rotating the handle up. d. Connect all cables to the module. The IBM BladeCenter S will detect that you have reinserted the RAID Controller and automatically powers it on. Replacing a media tray Perform the following steps to concurrently replace the IBM BladeCenter S chassis media tray using the RAID Controller command line interface.
Page 186
Existing Alerts : _____________________________________________________________________________________ |AlertCode| Id | Time |SlotID| Severity | | Ackable |MaskState| |=====================================================================================| 6 | 180 |20100219131844| Info |5005076b07419fff| 1 |Unmasked | IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
| Msg: Media tray was removed or swapped |=====================================================================================| 10. Insert the new media tray into the chassis. a. Slide the media tray into the IBM BladeCenter S chassis until it stops. b. Close the release handles (rotate the top handle down and the bottom handle up).
Page 188
7. Remove the Battery Backup Unit from the media tray. a. Open the release handle (rotate the handle down). b. Slide the Battery Backup Unit out of the media tray. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 189
Click Monitors > LEDs > Media Tray and Rear Panel LEDs. c. Click Off next to Location. The blue chassis identification LED will turn off. If the problem is not resolved, collect the logs and contact IBM. Replacing a Battery Backup Unit using the IBM Storage Configuration Manager Perform the following steps to concurrently replace the Battery Backup Unit (BBU) using the IBM Storage Configuration Manager.
In configurations where outage due to brown outs are unacceptable, ensure your system is protected with an Uninterrupted Power Supply (UPS) or other similar solution. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Data package collection in the intermediate state Issue: If you are using the IBM Storage Configuration Manager to collect a data package and one or more of your RAID Controllers is in an intermediate state you will not be able to collect this package, and the following message appears: The Collect Support Data operation is complete, with errors.
3. Verify no critical or warning alerts exist. If there are critical or warning alerts, resolve the issues that caused them before starting the firmware update process. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
How to reset the SAS RAID controllers to the factory defaults This section contains information about how to reset the SAS RAID Module to the factory defaults. Before you reset the SAS RAID Module to the factory defaults, you must end all application I/O processes and shut down any active Blade servers in accordance with the recommended non-concurrent practices.
Figure 26. Alert 9004 is caused by controller failed to flash the DSM firmware due to the firmware downgrade preventing mechanism of DSM_SFF module IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 195
Figure 27. <CLI> list controller 2. Perform RSSM firmware upgrade to the latest version of firmware (version 1.3.x.xxx or above). Please refer to IBM BladeCenter S SAS RAID Controller Module Installation and User's Guide Chapter 6 and 11 for detail instructions.
Page 196
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Appendix. Getting help and technical assistance If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. Use this information to obtain additional information about IBM and IBM products, determine what to do if you experience a problem with your IBM system or optional device, and determine whom to call for service, if it is necessary.
Standard upload with the system serial number: http://www.ecurep.ibm.com/ app/upload_hw v Secure upload: http://www.ibm.com/de/support/ecurep/ send_http.html#secure v Secure upload with the system serial number: https://www.ecurep.ibm.com/ app/upload_hw IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Software service and support Through IBM Support Line, you can get telephone assistance, for a fee, with usage, configuration, and software problems with your IBM products. For information about which products are supported by Support Line in your country or region, see http://www.ibm.com/services/supline/products.
Page 200
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
Therefore, a solid-state device has a maximum number of write cycles that it can be subjected to, expressed as “total bytes written” (TBW). A IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. Some software might differ from its retail version (if available) and might not include user manuals or all program functionality.
Further certification may be required by law prior to making any such connection. Contact an IBM representative or reseller for any questions. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
Verträglichkeit von Geräten Dieses Produkt entspricht dem “Gesetz über die elektromagnetische Verträglichkeit von Geräten (EMVG)”. Dies ist die Umsetzung der EU-Richtlinie 2004/108/EG in der Bundesrepublik Deutschland. IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
914-499-1900 Der verantwortliche Ansprechpartner des Herstellers in der EU ist: IBM Deutschland GmbH Technical Regulations, Abteilung M372 IBM-Allee 1, 71139 Ehningen, Germany Telephone: +49 7032 15 2941 Email: lugi@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse...
This is for any areas other than home. Russia Electromagnetic Interference (EMI) Class A statement People's Republic of China Class A electronic emission statement IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 209
Taiwan Class A compliance statement Notices...
Page 210
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...
Page 211
73, 97 Canada Class A electronic emission replacing 167 service mode command 97 statement 195 DSA, sending data to IBM 188 shellscript 75 capturing with FTDC utility 151 DSM 1 show raid levels 75 chassis replacing 161, 168...
Page 212
56 United States FCC Class A notice 195 Russia Class A electronic emission list features command 71 statement 198 list killedpaths command 88 IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module...