Initial Server Setup
S e n d d o c u m e n t c o m m e n t s t o u c s - d o c f e e d b a c k @ c i s c o . c o m
NIC Modes and NIC Redundancy Settings
This server has the following NIC mode settings that you can choose from:
•
•
•
Note
This server has the following NIC redundancy settings that you can choose from:
•
•
•
Cisco UCS C200 Server Installation and Service Guide
2-12
Dedicated—The two 10/100 management ports are used to access the CIMC. You have to select a
NIC redundancy and IP setting.
Shared LOM (default)—The two 1Gb Ethernet ports are used to access the CIMC. This is the factory
default setting, along with Active-active NIC redundancy and DHCP enabled.
Cisco Card—The ports on an installed Cisco network adapter card are used to access the CIMC. You
have to select a NIC redundancy and IP setting.
The Cisco Card NIC mode is currently supported only with a Cisco UCS P81E Virtual Interface
Card (N2XX-ACPCI01) that is installed in PCIe slot 2 (see
Special Considerations for the Cisco UCS P81E Virtual Interface Card (N2XX-ACPCI01),
page
3-27.
None—The Ethernet ports operate independently and do not fail over if there is a problem.
Active-standby—If an active Ethernet port fails, traffic fails over to a standby port.
Active-active—All Ethernet ports are utilized simultaneously.
Chapter 2
Installing the Server
Figure 3-15 on page
3-27). See also
OL-20732-02