hit counter script

Restoring Raid Configuration After Replacing A Raid Controller; For More Information - Cisco UCS C24 Installation And Service Manual

Table of Contents

Advertisement

Restoring RAID Configuration After Replacing a RAID Controller

Restoring RAID Configuration After Replacing a RAID Controller
When you replace a RAID controller, the RAID configuration that is stored in the controller is lost. Use
the following procedure to restore your RAID configuration to your new RAID controller.
Step 1
Replace your RAID controller. See
Step 2
If this was a full chassis swap, replace all drives into the drive bays, in the same order that they were
installed in the old chassis.
Step 3
Reboot the server and watch for the prompt to press F.
Step 4
Press F when you see the following on-screen prompt:
Foreign configuration(s) found on adapter.
Press any key to continue or 'C' load the configuration utility,
or 'F' to import foreign configuration(s) and continue.
Step 5
Press any key (other than C) to continue when you see the following on-screen prompt:
All of the disks from your previous configuration are gone. If this is
an unexpected message, then please power of your system and check your cables
to ensure all disks are present.
Press any key to continue, or 'C' to load the configuration utility.
Watch the subsequent screens for confirmation that your RAID configuration was imported correctly.
Step 6

For More Information

The LSI utilities have help documentation for more information about using the utilities.
For basic information about RAID and for using the utilities for the RAID controller cards, see the
Cisco UCS Servers RAID
Full LSI documentation is also available:
Cisco UCS C24 Server Installation and Service Guide
C-6
If you see the following message, your configuration was successfully imported. The LSI virtual
drive is also listed among the storage devices.
N Virtual Drive(s) found on host adapter.
If you see the following message, your configuration was not imported. This can happen if you do
not press F quickly enough when prompted. In this case, reboot the server and try the import
operation again wen you are prompted to press F.
0 Virtual Drive(s) found on host adapter.
Guide.
LSI MegaRAID SAS Software User's Guide (for LSI MegaRAID)
http://www.cisco.com/en/US/docs/unified_computing/ucs/3rd-party/lsi/mrsas/userguide/LSI_MR_SAS_SW_UG.pdf
Replacing a PCIe Card, page
Appendix C
RAID Controller Considerations
3-31.
OL-26647-01